SCT016T 16mm Aperture Split Core Current Transformer
Product Information:
SCT016T – 16mm Aperture Split core current transformer
The SCT016T is a split core current transformer with a 16mm
aperture. It is designed for accurate measurement of electrical
currents in various applications.
Characteristic:
- Installation diagram
- Primary threading method: Firing line
Product Application:
The SCT016T can be used in various electrical installations and
systems.
Product Advantage:
- Easy to install with a buckle fastening system
- Comes with lead wire for convenient connection
Typical Technical Index:
Output/Outer shell AC: 3.5KV/1min 5mA 50Hz
Electrical Parameters:
The following parameters are typical values and actual values
will be subject to product testing.
| Model | Max. Continuous Input Current | Input Current | Output | Turns Ratio | Load Resistance | Accuracy | Linearity | Weight |
|---|---|---|---|---|---|---|---|---|
| SCT016T | 10A | 10mA | 11000 | 10 | – | 0.5%/1% | 1% | 70g |
| SCT016T | 50A | 50mA | 11000 | 10 | – | 0.5%/1% | 1% | 70g |
| SCT016T | 50A | 25mA | 12000 | 10 | – | 0.5%/1% | 1% | 70g |
| SCT016T | 100A | 100mA | 11000 | 10 | – | 0.5%/1% | 1% | 70g |
| SCT016T | 100A | 50mA | 12000 | 10 | – | 0.5%/1% | 1% | 70g |
| SCT016T | 100A | 33mA | 13000 | 10 | – | 0.5%/1% | 1% | 70g |
| SCT016T | 100A | 20mA | 15000 | 10 | – | 0.5%/1% | 1% | 70g |
| SCT016T | 120A | 60mA | 12000 | 10 | – | 0.5%/1% | 1% | 70g |
| SCT016T | 120A | 40mA | 13000 | 10 | – | 0.5%/1% | 1% | 70g |
*Can be customized parameters/lead length/lead specifications
according to user requirements.
Wiring Schematic Diagram:

Outline Size:
16mm x 33.5mm x 6mm
For more information, please visit www.poweruc.pl
Front View:

Opening View:

Bottom View:

For output crimp terminal and side view, please refer to the
product documentation.
Product Usage Instructions:
- Open the buckle on the SCT016T.
- Lift the SCT016T upward to expose the opening.
- Insert the lead wire into the opening.
- Fasten the buckle to secure the lead wire.
Please follow the provided wiring schematic diagram for proper
installation.
Note: Ensure that the secondary does not allow short circuit
(for voltage output type) or open circuit (for current output
type).
SCT016T
16mmAperture Split core current transformer
Front view
Opening view
Bottom view
Characteristic
·Safety lock buckle, easy to install ·Built-in over-voltage protection
device (TVS tube) ·Crimping terminal output ·Suspended type
Installation diagram
Primary threading methodFiring line
Product application
·Portable instrument ·Household metering ·Monitor motor load
1.Open the buckle
2.Open upward
Product advantage
·Small volumeLight weight ·Low cost ·High turnsHigh precision
3.Put in lead wire
www.poweruc.pl
4.Fasten the buckle
Typical technical index
·Material of core—-Ferrite
·Working voltage—-Phase voltage720V
·Working temperature—–25+60
·Storage temperature—–30+90
·Frequency range—-50Hz1KHz
·Dielectric strength—-Inputcbare conductor/output AC 800V/1min 5mA 50Hz
Output/Outer shell AC 3.5KV/1min 5mA 50Hz
E l e c t r i c a l p a r a m e t e r s : The following parameters are typical values and actual values will be subject to product testing
Model
Max. continuous input current: 120% of rated input
Input current
Output
Turns ratio
Load resistance
Accuracy
Linearity Weight
SCT016T
10A
10mA 11000 10
0.5%/1% 1%
70g
SCT016T
50A
50mA 11000 10
0.5%/1% 1%
70g
SCT016T
50A
25mA 12000 10
0.5%/1% 1%
70g
SCT016T 100A 100mA 11000 10
0.5%/1% 1%
70g
SCT016T 100A 50mA 12000 10
0.5%/1% 1%
70g
SCT016T 100A 33mA 13000 10
0.5%/1% 1%
70g
SCT016T 100A 20mA 15000 10
0.5%/1% 1%
70g
SCT016T 120A 60mA 12000 10
0.5%/1% 1%
70g
SCT016T 120A 40mA 13000 10
0.5%/1% 1%
70g
Model SCT016T
Input current 10A
Output
Turns ratio
Load resistance
0.333V
–
built-in
Accuracy 0.5%/1%
Linearity Weight
1%
70g
SCT016T
30A 0.333V
–
built-in 0.5%/1% 1%
70g
SCT016T
50A 0.333V
–
built-in 0.5%/1% 1%
70g
SCT016T
80A 0.333V
–
built-in 0.5%/1% 1%
70g
SCT016T 100A 0.333V
–
built-in 0.5%/1% 1%
70g
SCT016T 120A 0.333V
–
built-in 0.5%/1% 1%
70g
*Can be customized parameters/lead length/lead
specifications according to user requirements.
www.poweruc.pl
Wiring schematic diagram
IP
k
R
l
Built-in sampling resistance Voltage output type
Secondary doesn’t allow short circuit
IP
k
TVS
l
TVSTransient voltage suppressor Current output type Secondary doesn’t allow open circuit
Outline size (in:mm)
16
33.5 6
55
Opening angle
180°
38 2.6
Front view
kl
Output crimp terminal
www.poweruc.pl