Hytronik Hc038v Daylight Harvest Pir Sensor Instruction Manual

HC038V Daylight Harvest PIR Sensor

Daylight Harvest PIR Sensor HC038V HCD038
Detached Linear Version with Remote Control
Applications Occupancy detector with daylight harvest suitable for indoor use.
Suitable for building into the fixture:
Office / Commercial Lighting Classroom
Use for new luminaire designs and installations

Features

Daylight harvest function to regulate light output for maintaining required lux level

Special photocell to measure and differentiate natural light from LED light
Photocell Advance
Intelligent Lux off function, daylight threshold prior to motion detection
Photocell
Optional 1-10V or DALI dimming control method

Ambientdaylight One-touch daylight learning via remote control threshold Zero crossing detection circuit reduces in-rush current and prolongs relay life (HC038V)

Loop in Loop out

Loop-in and loop-out terminal for efficient installation (HC038V)

5-Year Warranty

Technical Data
Input Characteristics Model No.
Mains voltage Stand-by power Load ratings:
HC038V
HCD038 Warming-up

HC038V HCD038 220_240VAC 50/60Hz
<0.5W
400VA (capacitive) 800W (resistive)
30mA, 16VDC (max. 15 devices) 20s

Safety and EMC EMC standard (EMC) Safety standard (LVD)
Radio Equipment (RED)
Certification

EN55015, EN61000 EN60669, AS/NZS60669
EN300440, EN301489, EN62479
Semko, CB, CE , EMC, RED, RCM

RED

IP20

Subject to change without notice.

Sensor Data

Model No.

HIR01 HIR01/FM HIR03 HIR09/S HIR09/F HIR09/C

Sensor principle

PIR Detection

Operation voltage

5VDC

Detection range

HIR01 HIR01/FM HIR03
Max installation height Max Detection range
HIR09

3m 6m (Diameter)

Max installation height Max Detection range (Ø)

15m (forklift) 12m (single person) 24m (forklift) 20m (single person)

Detection angle

360O

Environment Operation temperature Case temperature (Max.) IP rating

Ta: -20OC ~ +55OC Tc: +80OC IP20

Edition: 26 Feb. 2020 Ver. A0 Page 1/9

Sensor Main Body
HC038V (1-10V output) RJ12 connector 1-10V1-10V+
HCD038 (DALI output) RJ12 connector

Push L’ N
LN
DALI Push

LN
There are three different PIR sensor antenna modules to choose from:

PIR Sensor Head Model HIR01

Lens Installation hole

RJ12 connector

30 35 39.5

2.5 30
1.5 16
23.3 25.8

4.5

120
4.5 110.5

21

30

20.3 21.5 26.5 35.3

PIR Sensor Head

Lens

Model HIR01/FM

PIR Sensor Head Model HIR03

Lens RJ12 connector

Ø48
Ø13.8 40.9 44.5

16.4 17 19.3 17.8 15.9 12.9

38.9

Subject to change without notice.

Edition: 26 Feb. 2020 Ver. A0 Page 2/9

20 23.2
32.6 17
Ø1Ø7.3.55

PIR Sensor Head

HIR09/S

Lens Housing

Surface mounting For highbay application

IP65 (facia/lens part) The cable length is around 30cm.

RJ12 connector Lug

Ø 36.3

HIR09/F

Lens Accessories

Flush mounting

For highbay application

Ø 48

IP65 (facia/lens part) The cable length is around 30cm.

RJ12 connector

HIR09/C
Screw to the luminaire by conduit For highbay application
IP65 (facia/lens part) The cable length is around 30cm.

Lens Accessories

RJ12 connector

Ø 40.5

M13

12 42.7 63

25 25 33.9
Ø14

1.2 21.5
30.4 Ø41

Installation hole Installation hole
Installation hole

12 sensor antennas and 2 control units offer 24 combinations in total:

A PIR antenna HIR01 + DALI control HCD038 C PIR antenna HIR01/FM + DALI control HCD038 E PIR antenna HIR03 + DALI control HCD038 G PIR antenna HIR09/S + DALI control HCD038 I PIR antenna HIR09/F + DALI control HCD038
K PIR antenna HIR09/C + DALI control HCD038

B PIR antenna HIR01 + 1-10V control HC038V D PIR antenna HIR01/FM + 1-10V control HC038V F PIR antenna HIR03 + 1-10V control HC038V H PIR antenna HIR09/S + 1-10V control HC038V J PIR antenna HIR09/F + 1-10V control HC038V
L PIR antenna HIR09/C + 1-10V control HC038V

Photocell AdvanceTM

Intelligent Photocell

Ambient daylight threshold

Loop in Loop out

Detection Pattern

0

3

5

Note:We recommend the mounting distance between sensor to sensor should be more than 2m to prevent sensors from false-triggering.

Subject to change without notice.

Edition: 26 Feb. 2020 Ver. A0 Page 3/9

Functions and Features
1 Daylight Harvest

Light will not switch on when natural light is sufficient, even there is motion detected.

The light switches on automatically with presence when natural light is insufficient.

The light turns on at full or dims to maintain the lux level. The light output regulates according to the level of natural light available.

The light switches off when the ambient natural light is sufficient.

The light dims to stand-by period after hold-time and stays on selected minimum dimming level.

The light switches off completely after the stand-by period.

Note: The Light automatically dims down and eventually turns off if the natural light lux level exceeds the daylight threshold. However, if the stand-by period is preset at “+”, the fixture never switches off but dim to minimum level, even the natural light is sufficient.

2 Photocell AdvanceTM Function (HIR03)
It’s well known that LED lights have a totally different spectrum to natural light. Hytronik uses this principle and comes up with special photocell and sophisticated software algorithm to measure and differentiate natural light from LED light, so that this photocell can ignore the LED light and only respond to the natural light. Our technology has no infringement to the existing patents in the market.

3 Lux Off Function The light turns off automatically whenever surrounding natural light lux level exceeds the daylight threshold for more than 5min, even there is motion detected. However, if the stand-by period is pre-set to infinity “+”, the fixture never switches off but stays at dimming level, even when natural light is sufficient .
4 Manual Override This sensor reserves the access of manual override function for end-user to switch on/off, or adjust the target lux level by push-switch, which makes the product more user-friendly and offers more options to fit some extra-ordinary demands:
* Short Push (<1s): on/off function; On ¹ Off: the light turns off immediately and cannot be triggered ON by motion until the expiration of pre-set hold-time. After this period, the sensor goes back to normal sensor mode. Off ¹ On: the light turns on and goes to sensor mode, no matter if ambient Lux level exceeds the daylight threshold or not.
* Long Push (>1s): adjust the target lux level by turning the light up or down. Both the adjustment on RC and push switch can overwrite each other, the last adjustment remains in memory.
Note: if end-user do not want this manual override function, just leave the “push” terminal unconnected to any wire.

Subject to change without notice.

Edition: 26 Feb. 2020 Ver. A0 Page 4/9

5 Zero-cross Relay Operation (HC038V)
Designed in the software, sensor switches on/off the load right at the zero-cross point, to ensure that the in-rush current is minimised, enabling the maximum lifetime of the relay.

zero-cross point Alternating current

P

HC038V L’

1-10V 1-10V+

N N L

L N

L N
1-10V+ 1-10V-

LED Driver

Wiring Diagram

L N
1-10V+ 1-10V-

LED Driver

L N
Detection Pattern
HIR01 HIR01/FM HIR03

DALI

DALI

HCD038

Push

N

L

DALI

DALI L

DALI Driver

N

DALI

DALI L

DALI Driver

N

1. 200 metres (total) max. for 1mm² CSA (Ta = 50) 2. 300 metres (total) max. for 1.5mm² CSA (Ta = 50)

3m

walking across

walking towards radialtamnogveenmtiaelnmt 3o.v2emment 6m

Subject to change without notice.

Edition: 26 Feb. 2020 Ver. A0 Page 5/9

HIR09 (High-bay)

HIR09 : High-bay lens detection pattern for forklift @ Ta = 20¥ (Recommended installation height 10m-15m)

A: Tangential movement B: Radial movement

h = max.15m ”
Tangential: max. 24m

h = max.15m
# Radial: max. 16m

insensitive

sensitive

insensitive

sensitive

Mount height 10m 11m 12m 13m 14m 15m

Tangential (A) max 380m2 (Ø = 22m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m) max 452m2 (Ø = 24m)

Radial (B) max 201m2 (Ø = 16m) max 201m2 (Ø = 16m) max 201m2 (Ø = 16m) max 177m2 (Ø = 15m) max 133m2 (Ø = 13m) max 113m2 (Ø = 12m)

HIR09 : High-bay lens detection pattern for single person @ Ta = 20¥ (Recommended installation height 2.5m-12m)

A: Tangential movement

B: Radial movement

h = max.12m

Tangential: max. 20m

h = max.12m

#

Radial: max. 3m

insensitive

sensitive

insensitive

sensitive

Mount height 2.5m 6m 8m 10m 11m 12m

Tangential (A) max 50m2 (Ø = 8m)

Radial (B) max 7m2 (Ø = 3m)

max 104m2 (Ø = 11.5m) max 7m2 (Ø = 3m) max 154m2 (Ø = 14m) max 7m2 (Ø = 3m)

max 227m2 (Ø = 17m) max 7m2 (Ø = 3m) max 269m2 (Ø = 18.5m) max 7m2 (Ø = 3m) max 314m2 (Ø = 20m) max 7m2 (Ø = 3m)

Subject to change without notice.

Edition: 26 Feb. 2020 Ver. A0 Page 6/9

Settings (Remote Control HRC-11, for HIR01/FM & HIR03 & HIR09)

ON/ OFF

Permanent ON/OFF function

Press button “ON/OFF” to select permanent ON or permanent OFF mode. * Press button “AUTO”, “RESET” or “Ambient” to quit this mode. The mode will change to AUTO Mode after power failure.

Reset Settings
Press button “RESET”, all settings go back to default values. For HIR01/FM: Detection range: 100%; Hold-time: 5min; Stand-by period: 10min;
Stand-by dimming level: 20%; Constant lux: 100lux For HIR03: Detection range: 100%; Hold-time: 5min; Stand-by period: 10min;
Stand-by dinmming level:10%; Lux disabled For HIR09: Detection range: 100%; Hold-time: 5min; Stand-by period: 10min;
Stand-by dimming level: 20%; Constant lux: 100lux
Shift Button
Press button “Shift”, the LED on the top left corner is on to indicate mode selection. All values / settings in RED are valid for 20 seconds.

AUTO mode
Press button “AUTO” to initiate automatic mode. The sensor starts working and all settings remain as before the light is switched ON/OFF.
SEMI-AUTO mode
1. Press button “Shift”, the red LED flashes for indication. 2. Press button “SEMI-AUTO/AUTO” to initiate semi-auto mode. The fixture is manually turned on by pressing the push-switch, and goes off automatically after stand-by time. (Absence detection mode)

& A

4h

h

4h

HRC-11

Power output
Press the buttons to select light output at 80% (at initial 10,000 hours) or 100%. Note: “Sensor off” and “Twilight” functions are disabled.

Brightness +/-
Press these two buttons to adjust the light output brightness and set a new target lux level. The daylight sensor can measure ambient daylight level and ignore the LED light, so as to calculate how much artificial light is needed to maintain the target lux level.

Scene program – 1-key commissioning
1. Press button “Start” to program. 2. Select the buttons in “Detection range”, “Daylight threshold”, “Hold-time”, “Stand-by time”, “Stand-by dimming level” to set all parameters. 3. Press button “Memory” to save all the settings programmed in the remote control. 4. Press button “Apply” to set the settings to each sensor unit(s).
For example, to set detection range 100%, daylight threshold Disable, hold-time 5min, stand-by time +, stand-by dimming level 30%, the steps should be: Press button “Start”, button “100%”, “Disable”, “Shift”, “5min”, “Shift”, “+”, “30%”, “Memory”. By pointing to the sensor unit(s) and pressing “Apply”, all settings are passed on the sensor(s).

Detection range Buttons in zone “Detection range” are disabled.
Subject to change without notice.

Edition: 26 Feb. 2020 Ver. A0 Page 7/9

Daylight threshold Press buttons in zone ” Daylight threshold” to set daylight sensor at 2Lux/ 10Lux / 50Lux / 100Lux / 300Lux / 500Lux / Disable. Note: To set daylight sensor at 100Lux / 300Lux / 500Lux, press “Shift” button first.
Ambient daylight threshold 1. Press button “Shift”, the red LED starts to flash. 2. Press button “Ambient”, the surrounding lux level is sampled and set as the new daylight threshold.

Hold-time
Press buttons in zone “hold-time” to set the hold-time at 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min. Note: 1. To set hold-time at 30s / 5min / 15min / 30min, press “Shift” button first.
2. 2s is for testing purpose only, stand-by period and daylight sensor settings are disabled in this mode. *To exit from Test mode, press button “RESET” or any button in “Hold-time”.

Stand-by time (corridor function)
Press buttons in zone “stand-by time” to set the stand-by period at 0s / 10s / 1min / 5min / 10min / 30min / 1h / +. Note: “0s” means on/off control; “+” means the stand-by time is infinite and the fixture never switches off.

Stand-by dimming level Press the button in zone “stand-by dimming level” to set the stand-by dimming level at 10% / 20% / 30% / 50%.
Auto-configuration function All buttons in this zone are disabled.
Dual tech & RF mode All buttons in this zone are disabled.

Settings (Remote Control HRC-01, for HIR01)


ON/ OFF

Permanent ON/OFF function

Press the “ON/OFF” button, the light goes to permanent on or permanent off mode, and the sensor is disabled. * Press “Auto Mode”, “RESET” or “Scene mode” buttons to quit this mode. The mode will change to AUTO Mode after power failure.

Auto Mode Sensor mode
Press “Auto Mode” button, the sensor starts to function and all settings remain the same as the latest status before the light is switched on/off.

RESET Reset function
Press “RESET” button, all settings go back to default value (same as scene mode 3): Detection range: 100%; Hold-time: 5min; Stand-by period: 10min; Stand-by dimming level: 20%; Constant lux: 100lux

+

Dim +/

Press these two buttons to adjust the light output brightness and set a new target lux level. The daylight sensor can measure ambient daylight level and ignore the LED light, so as to calculate how much artificial light is needed to maintain the target lux level.

ON/ OFF

Auto Mode

RESET

SC1 SC2 SC3
Scene mode
SC4 SC5 SC6
Detection range
100% 75% 50%

+
Dim
10%

30S 10min

1min 5min
Hold-time
20min 30min

TEST 2S
8H

8

0S

10S 1min

Stand-by-period

10min 30min 1H

Stand-by dimming level

10% 20% 30%

5min + 50%

HRC-01
Note: the buzzer beeps one time when RC receives signal successfully.

Subject to change without notice.

Edition: 26 Feb. 2020 Ver. A0 Page 8/9

Test mode
This button is for testing purpose only. The sensor goes to test mode (hold-time is 2s) after commissoning, meanwhile the stand-by period and daylight sensor are disabled. * This mode can be ended by pressing “reset”, or any button of “scene mode” and “hold-time”. The sensor settings are changed
accordingly.

8H 8H permanent on mode
In some circumstances, people want to disable the sensor and keep the light on for a certain period of time, even there is no motion detected. This function is built-in the software and can be achieved by pressing the “8H” button on the RC. * Press “ON/OFF”, “Auto Mode”, “RESET” or “Scene mode” buttons to quit from this mode.

Scene mode There are 6 scene modes fixed program built-in the remote control to choose for different applications:

Scene options SC1 SC2 SC3 SC4 SC5 SC6

Hold-time 1min 3min 5min 10min 20min 30min

Stand-by period 1min 5min 10min 30min 1H +

Stand-by dimming level 10% 20% 20% 30% 30% 50%

Constant Lux 50Lux 75Lux 100Lux 150Lux 200Lux 400Lux

Detection range disabled disabled disabled disabled disabled disabled

* End-user can adjust the settings by pressing buttons of detection range/hold-time/stand-by period/stand-by dimming level/daylight sensor. The last setting stays in validity.

Hold-time Press the buttons of “hold-time” to set hold-time at 30s / 1min / 5min / 10min / 20min / 30min .

Stand-by period (Corridor function) Press the buttons of “stand-by period ( corridor function)” to set stand-by period at 0s/10s/1min/5min/10min/30min/1H/+. Note: “0s” means on/off control; “+” means bi-level dimming control and the fixture never switches off.
Stand-by dimming level Press the buttons of “stand-by dimming level” to set the stand-by dimming level at 10%/20%/30%/50%.
Detection range Buttons of “detection range” are disabled.
Additional Information / Documents
1. For full explanation of Hytronik Photocell AdvanceTM technology, please kindly refer to www.hytronik.com/download ->knowledge ->Introduction of Photocell Advance
2. Regarding precautions for microwave sensor installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->Microwave Sensors – Precautions for Product Installation and Operation
3. Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy

Subject to change without notice.

Edition: 26 Feb. 2020 Ver. A0 Page 9/9

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals