2541-726 Baldwin Park 4.5 Inch 1 Light Coal and Soft Brass Transitional Vanity Light
Product Information
Product Name: Item#2541-726
Installation Date: 02/18/2022
Installation Instructions
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU
DISJONCTEUR.
Mounting the Fixture (Fig. 1)
- Shut off power at the fuse box or circuit breaker box and
remove the old fixture including the mounting hardware. - Carefully unpack your new fixture and lay out all the parts in
a clear area. Take care not to misplace any small parts necessary
for installation. - Thread all thread (E) into crossbar (C). Note: The length of
all thread (E) into crossbar (C) may be adjusted, if
necessary. - Secure all thread (E) to crossbar (C) using lock washer (B) and
hex nut (A). - Take this crossbar assembly (C) and mount it to outlet box (not
included) with mounting screws (D) (Size: #8-32N*L0.5). The side of
crossbar marked with GND must face out.
Connecting the Wires (Fig. 2)
Connect the electrical wires as shown in Fig. 2, making sure
that all wire connectors are secured. If your outlet box has a
ground wire (green or bare copper), connect the fixture’s ground
wire to it. Otherwise, connect the fixture’s ground wire directly
to the crossbar (C) using the green screw provided. After the wires
are connected, tuck them carefully inside the outlet box.
Completing the Installation (Fig. 1)
- Place fixture body (F) over all thread (E) and secure with
finial (G). - Install (1) one medium base T10 bulb (I) up to 60 watts each or
CFL or LED equivalent (not included) in accordance with the fixture
specification — DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS
DEPASSER LA PUISSANCE NOMINALE MAXIMALE!). - Place glass shade (J) over socket (H).
Your installation is now complete. Return power to the junction
box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation
purposes only. It may or may not be identical to the fixture
purchased.
Wire Connections
FIXTURE WIRES Black or Smooth – HOUSE WIRES Black (Hot)
FIXTURE WIRES White or Ribbed – HOUSE WIRES White (Neutral)
FIXTURE WIRES Bare Copper (Ground) – HOUSE WIRES Green
(Ground)
LA-3509E
INSTALLATION INSTRUCTIONS
Item#2541-726 (New. 02/18/2022) READ AND SAVE THESE INSTRUCTIONS
W ARNING! SHUT POWE R OFF AT FUSE O R CIRCUIT BRE AKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
MOUNTING THE FIXTURE (Fig. 1) 1. Shut off power at the fuse box or circuit breaker box and Fig.1
remove the old fixture including the mounting hardware. Set# A-010
2. Carefully unpack your new fixture and lay out all the parts – Crossbar
in a clear area. Take care not to misplace any small parts
– Ground screw – Mounting Screw*2
necessary for installation.
3. Thread all thread (E) into crossbar (C). Note: The length
of all thread (E) into crossbar (C) may be adjusted, if
necessary.
4. Secure all thread (E) to crossbar (C) using lock washer
J
(B) and hex nut (A).
5. Take this crossbar assembly (C) and mount it to outlet box
(not included) with mounting screws (D) (Size:
#8-32N*L0.5″). The side of crossbar marked with “GND”
must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the electrical wires as shown in Fig. 2, making
A
I
D
sure that all wire connectors are secured. If your outlet
box has a ground wire (green or bare copper), connect
B
the fixture’s ground wire to it. Otherwise, connect the
C
H
fixture’s ground wire directly to the crossbar (C) using the green screw provided. After the wires are connected, tuck them carefully inside the outlet box.
E F
G
COMPLETING THE INSTALLATION (Fig.1)
7. Place fixture body (F) over all thread (E) and secure with
finial (G).
8. Install (1) one medium base T10 bulb (I) up to 60 watts
each or CFL or LED equivalent (not included) in
accordance with the fixture specification — DO NOT
EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS Fig. 2
DEPASSER LA PUISSANCE NOMINALE MAXIMALE!). 9. Place glass shade (J) over socket (H).
FIXTURE WIRES Black or Smooth
FIXTURE WIRES White or Ribbed
FIXTURE WIRES Bare Copper (Ground)
Your installation is now complete. Return power to the junction box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.
HOUSE WIRES Black (Hot)
HOUSE WIRES White (Neutral)
HOUSE WIRES Green (Ground)
LA-3509E