  • If large debris becomes lodged in the brush roll, it will automatically shut off
    • Unplug machine and remove obstruction
    • Wait 15 minutes for the motor to cool down before turning back on
    • After this time, the brush should function correctly
  • If no obstruction found the belt may be broken OR the brush roll may need to be cleaned of debris
  • Remove foot assembly by pressing button on back of foot assembly and pulling foot

 

  • Turn the foot assembly over and remove the 3 Philips head screws from the brush cover
  • Remove the brush roll to access the belt
  • Check the end caps on the brush roll for damage or debris
    • Clean brush of debris build-up
    • If belt or brush are damaged, they should be replaced
  • When brush is cleaned, reattach belt and reassemble into machine
  • Re-secure brush cover with the 3 screws
  • Reattach foot assembly onto machine
    • Once reassembled if brush still does not turn, please Contact Us

 