Cdc-26122-xn1a Arrowg+ard Blue Two-lumen Hemodialysis Catheterization For High Volume Infusions Instructions

CDC-26122-XN1A Arrowg+ard Blue Two-Lumen Hemodialysis Catheterization for High Volume Infusions

Product Information:

  • Product Name: CDC-26122-XN1A
  • Catheter Type: Two-lumen catheter
  • Catheter Size: 12 2 Fr.
  • Catheter Length: 25 cm
  • Guide Wire Diameter: 0.035 inch
  • Contents:
    • Catheter: 18 Ga. x 2-1/2 (6.35 cm) Radiopaque over 20 Ga. RW
      Introducer Needle
    • Raulerson Spring-Wire Introduction Syringe
    • Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2 (3.81 cm) and 5
      mL Luer-Slip
  • Contraindications:
    • Not suitable for long-term (30 days) hemodialysis
    • Not suitable for use in patients with thrombosed vessels
    • Arrowg+ard Blue antimicrobial catheter is contraindicated for
      patients with known hypersensitivity to chlorhexidine, silver
      sulfadiazine, and/or sulfa drugs

Product Usage Instructions:

  1. Prepare the patient and the necessary equipment for catheter
    insertion.
  2. Ensure that the catheter is properly sterilized before
    use.
  3. Select an appropriate insertion site and clean the area with an
    antiseptic solution.
  4. Using the provided introducer needle, perform the initial
    puncture at the selected site.
  5. Advance the catheter into the vessel while removing the
    introducer needle.
  6. Secure the catheter in place using the appropriate fixation
    method.
  7. Connect the Raulerson Spring-Wire Introduction Syringe to the
    catheter for priming.
  8. Prime the catheter by injecting 1.40 mL of fluid into the
    distal lumen and 1.60 mL into the proximal lumen.
  9. Ensure that the priming volumes are approximate and are done
    without accessories.
  10. Monitor the pressure and flow rate during dialysis using the
    provided dialysis flow rate chart.
  11. Follow the recommended flow rate for venous and arterial lines
    according to the chart.

Note: It is important to read and understand the complete user
manual before using the product. Consult a healthcare professional
for any specific usage guidelines or concerns.

CDC-26122-XN1A

12 2 Fr.

Lumen

25 cm catheter length

.035 inch dia. spring-wire guide

Arrowg+ard Blue® Two-Lumen Hemodialysis Catheterization for High Volume Infusions

Contents:
1: Two-Lumen Catheter: 12 Fr. (4.06 mm OD) x 25 cm Radiopaque Polyurethane with Blue FlexTip®, Arrowg+ard® Antimicrobial Surface Treatment, Extension Line Clamps
1: Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow® GlideWheelTM Wire Advancer
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
1: Injection Needle: SafetyGlideTM1 25 Ga. x 1″ (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm) 1: Pressure Transduction Probe 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow®
Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip
Syringe 1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm 1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm 2: 10 mL Luer-Lock Pre-Filled Saline Syringe 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep 2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with

Hi-Lite OrangeTM Tint 1: SharpsAway® II Locking Disposal Cup 1: SharpsAway® Disposal Cup 1: Maximal Barrier DrapeTM with 4″ fenestration 1: Towel 1: Needle Holder 1: Safety Scalpel: #11 1: Checklist/CLIP Sheet 1: Sterile Procedure Sign 1: Medication Label: 1% Lidocaine 2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm) 5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm) 1: Surgical Apparel: Impervious Gown 1: Dressing: I.V. Advanced 8.5 cm x 11.5 cm 1: Dressing: BIOPATCH®3 1: Transducer Cover: 14 cm x 147 cm 1: Surgical Apparel: Mask with Eye Shield 1: Surgical Apparel: Bouffant Cap 1: Suture: 3-0 Silk with Curved Needle 1: Tubing±: 20″ (50 cm) Extension 1: HemoHopper® Fluid Receptacle

±Precaution: Contains Phthalate: DEHP. Warning: The results of certain animal experiments have shown phthalates to be potentially toxic to reproduction. Proceeding from the present state of scientific knowledge, risks for male premature infants cannot be excluded in the case of long-term exposure or application. Medical products containing phthalates should be used only temporarily with pregnant women, nursing mothers, babies and infants. Not made with natural rubber latex. Store between 20 ­ 25°C (68 ­ 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.
Contraindications: The Arrow large-bore two-lumen catheter is not designed for long-term ( 30 days) hemodialysis or for use in patients with thrombosed vessels. The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/ or sulfa drugs.

1A trademark of Becton, Dickinson and Company. 2A registered trademark of CareFusion or one of its subsidiaries. 3A registered trademark of Johnson & Johnson Corporation.

Priming Volume*

Distal Proximal

1.40 mL 1.60 mL

* Priming volumes are approximate and are done without accessories.

Pressure (mmHg)

Dialysis Flow Rate

500

400

300

200

100 0
-100

VENOUS ARTERIAL

-200

-300

100 200 300 400 500

Flow (mL/min)

In vitro tests performed using 3:1 glycerine/saline at 37°C.

LBL068966 R00 (2023-04)

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals