CDC-25142-XN1A Arrowg+ard Blue Two-Lumen Hemodialysis Catheterization for High Volume Infusions
Product Information
- Product Name: CDC-25142-XN1A
- Size: 14 2 Fr.
- Lumen: Single
- Catheter Length: 20cm
- Guide Wire Diameter: 0.035 inch
Contents:
- Catheter: 18 Ga. x 2-1/2 (6.35 cm) Radiopaque over 20 Ga. RW
Introducer Needle - Raulerson Spring-Wire Introduction Syringe
- Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2 (3.81 cm)
- 5 mL Luer-Slip
Contraindications:
The Arrow large-bore two-lumen catheter is not designed for
long-term (30 days) hemodialysis or for use in patients with
thrombosed vessels. The Arrowg+ard Blue antimicrobial catheter is
contraindicated for patients with known hypersensitivity to
chlorhexidine, silver sulfadiazine, and/or sulfa drugs.
1A trademark of Becton, Dickinson and Company. 2A registered
trademark of CareFusion or one of its subsidiaries. 3A registered
trademark of Johnson & Johnson Corporation.
Priming Volume:
| Distal | Proximal | |
|---|---|---|
| Volume (mL) | 1.70 | 1.50 |
Pressure (mmHg) vs. Flow (mL/min):
Dialysis Flow Rate:
- 300 mL/min: -100 mmHg
- 200 mL/min: -200 mmHg
- 100 mL/min: -300 mmHg
- 0 mL/min: No pressure
- -100 mL/min: 100 mmHg
- -200 mL/min: 200 mmHg
- -300 mL/min: 300 mmHg
- 400 mL/min: 400 mmHg
- 500 mL/min: 500 mmHg
LBL068970 R00 (2023-04)
Product Usage Instructions:
- Ensure that the patient does not have thrombosed vessels or
known hypersensitivity to chlorhexidine, silver sulfadiazine,
and/or sulfa drugs. - Prepare the catheter by connecting the introducer needle and
the spring-wire introduction syringe. - Insert the catheter into the desired location according to the
medical procedure requirements. - If necessary, use the injection needle for additional
injections. - Monitor the dialysis flow rate and corresponding pressure to
ensure proper functioning of the catheter.
CDC-25142-XN1A
14 2 Fr.
Lumen
20cm catheter length
.035 inch dia. spring-wire guide
Arrowg+ard Blue® Two-Lumen Hemodialysis Catheterization for High Volume Infusions
Contents:
1: Two-Lumen Catheter: 14 Fr. (4.72 mm OD) x 20 cm Radiopaque Polyurethane with Blue FlexTip®, Arrowg+ard® Antimicrobial Surface Treatment, Extension Line Clamps
1: Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow® GlideWheelTM Wire Advancer
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
1: Injection Needle: SafetyGlideTM1 25 Ga. x 1″ (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm) 1: Pressure Transduction Probe 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow®
Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip
Syringe 1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 14 Fr. (4.7 mm) x 14 cm 1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm 2: 10 mL Luer-Lock Pre-Filled Saline Syringe 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep 2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with
Hi-Lite OrangeTM Tint 1: SharpsAway® II Locking Disposal Cup 1: SharpsAway® Disposal Cup 1: Maximal Barrier DrapeTM with 4″ fenestration 1: Towel 1: Needle Holder 1: Safety Scalpel: #11 1: Checklist/CLIP Sheet 1: Sterile Procedure Sign 1: Medication Label: 1% Lidocaine 2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm) 5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm) 1: Surgical Apparel: Impervious Gown 1: Dressing: I.V. Advanced 8.5 cm x 11.5 cm 1: Dressing: BIOPATCH®3 1: Transducer Cover: 14 cm x 147 cm 1: Surgical Apparel: Mask with Eye Shield 1: Surgical Apparel: Bouffant Cap 1: Suture: 3-0 Silk with Curved Needle 1: Tubing±: 20″ (50 cm) Extension 1: HemoHopper® Fluid Receptacle
±Precaution: Contains Phthalate: DEHP. Warning: The results of certain animal experiments have shown phthalates to be potentially toxic to reproduction. Proceeding from the present state of scientific knowledge, risks for male premature infants cannot be excluded in the case of long-term exposure or application. Medical products containing phthalates should be used only temporarily with pregnant women, nursing mothers, babies and infants. Not made with natural rubber latex. Store between 20 25°C (68 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.
Contraindications: The Arrow large-bore two-lumen catheter is not designed for long-term ( 30 days) hemodialysis or for use in patients with thrombosed vessels. The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/ or sulfa drugs.
1A trademark of Becton, Dickinson and Company. 2A registered trademark of CareFusion or one of its subsidiaries. 3A registered trademark of Johnson & Johnson Corporation.
Priming Volume*
Distal Proximal
1.70 mL 1.50 mL
* Priming volumes are approximate and are done without accessories.
Pressure (mmHg)
Dialysis Flow Rate 300
200
100 0
-100
VENOUS ARTERIAL
-200
-300
100
200
300
400
500
Flow (mL/min)
In vitro tests performed using 3:1 glycerine/saline at 37°C.
LBL068970 R00 (2023-04)