CDC-22122-XCN1A Arrowg+ard Blue® Two-Lumen Hemodialysis Catheterization for High Volume Infusions
Product Information:
Product Name: CDC-22122-XCN1A
Catheter Type: Large-bore two-lumen catheter
Catheter Size: 12 2 Fr.
Lumen: Single lumen
Catheter Length: 16 cm
Guide Wire Diameter: 0.035 inch (spring-wire guide)
Contents:
- Catheter: 18 Ga. x 2-1/2 (6.35 cm) Radiopaque over 20 Ga. RW
Introducer Needle - Raulerson Spring-Wire Introduction Syringe
- Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2 (3.81 cm) and 5
mL Luer-Slip - Hi-Lite OrangeTM Tint
Trademarks: SafetyGlideTM1 (Becton, Dickinson and Company),
Hi-Lite OrangeTM (3M Company)
Contraindications:
- The Arrow large-bore two-lumen catheter is not designed for
long-term (30 days) hemodialysis. - The Arrow large-bore two-lumen catheter is not suitable for use
in patients with thrombosed vessels. - The Arrowg+ard Blue antimicrobial catheter is contraindicated
for patients with known hypersensitivity to chlorhexidine, silver
sulfadiazine, and/or sulfa drugs.
Product Usage Instructions:
- Ensure that the catheter is properly sterilized before
use. - Select an appropriate insertion site and prepare the area by
cleaning it with an antiseptic solution. - Using the provided Raulerson Spring-Wire Introduction Syringe,
insert the catheter into the desired location. - Advance the catheter carefully, following the recommended
insertion technique. - Once the catheter is in place, secure it to the patient’s skin
using a suitable dressing or securement device. - If necessary, connect the catheter to external devices or
tubing according to the specific medical procedure or treatment
being performed. - After use, dispose of the catheter and any associated materials
according to medical waste disposal guidelines.
Note: It is important to follow all instructions provided by
healthcare professionals and refer to the complete user manual for
detailed usage guidelines and precautions.
CDC-22122-XCN1A
12 2 Fr.
Lumen
16 cm catheter length
.035 inch dia. spring-wire guide
Arrowg+ard Blue® Two-Lumen Hemodialysis Catheterization for High Volume Infusions
Contents:
1: Two-Lumen Catheter: 12 Fr. (4.06 mm OD) x 16 cm Radiopaque Polyurethane with Blue FlexTip®, Arrowg+ard® Antimicrobial Surface Treatment
1: Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow® GlideWheelTM Wire Advancer
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
1: Injection Needle: SafetyGlideTM1 25 Ga. x 1″ (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm) 1: Pressure Transduction Probe 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow®
Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip
Syringe 1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm 1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm 2: 10 mL Luer-Lock Pre-Filled Saline Syringe 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep 2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with
Hi-Lite OrangeTM Tint
1: SharpsAway® II Locking Disposal Cup 1: SharpsAway® Disposal Cup 1: Maximal Barrier DrapeTM with 4″ fenestration 1: Towel 1: Needle Holder 1: Safety Scalpel: #11 1: Checklist/CLIP Sheet 1: Sterile Procedure Sign 1: Medication Label: 1% Lidocaine 2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm) 5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm) 1: Surgical Apparel: Impervious Gown 1: Dressing: Tegaderm®3 CHG 3-1/2″ x 4-1/2″ (8.5 cm x 11.5 cm) 1: Transducer Cover: 14 cm x 147 cm 1: Surgical Apparel: Mask with Eye Shield 1: Surgical Apparel: Bouffant Cap 1: Suture: 3-0 Silk with Curved Needle 1: Tubing±: 20″ (50 cm) Extension 1: HemoHopper® Fluid Receptacle
1A trademark of Becton, Dickinson and Company. 2A registered trademark of CareFusion or one of its subsidiaries.
±Precaution: Contains Phthalate: DEHP. Warning: The results of certain animal experiments have shown phthalates to be potentially toxic to reproduction. Proceeding from the present state of scientific knowledge, risks for male premature infants cannot be excluded in the case of long-term exposure or application. Medical products containing phthalates should be used only temporarily with pregnant women, nursing mothers, babies and infants. Not made with natural rubber latex. Store between 20 25°C (68 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.
Contraindications: The Arrow large-bore two-lumen catheter is not designed for long-term ( 30 days) hemodialysis or for use in patients with thrombosed vessels. The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/ or sulfa drugs.
3A registered trademark of 3M Company.
Priming Volume*
Distal Proximal
1.40 mL 1.30 mL
* Priming volumes are approximate and are done without accessories.
Pressure (mmHg)
Dialysis Flow Rate 300
200
100
VENOUS 0
ARTERIAL
-100
-200
-300
100
200
300
400
500
Flow (mL/min)
In vitro tests performed using 3:1 glycerine/saline at 37°C.
LBL068963 R00 (2023-04)