CDC-12123-XPN1A Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions
Product Information:
Product Name: CDC-12123-XPN1A
Product Type: Pressure Injectable Three-Lumen
Hemodialysis Catheterization
Catheter Size: 12 3 Fr.
Catheter Length: 16 cm
Spring-Wire Guide Diameter: 0.035 inch
Contents:
- Catheter: 18 Ga. x 2-1/2 (6.35 cm) Radiopaque over 20 Ga. RW
Introducer Needle - Raulerson Spring-Wire Introduction Syringe
- Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2 (3.81 cm) and 5
mL Luer-Slip
Tint: Hi-Lite OrangeTM
Trademark: Becton, Dickinson and Company
Contraindications: The Multi-Lumen Acute
Hemodialysis Catheter (AHDC) is not designed for long-term (30
days) hemodialysis or for insertion into thrombosed vessels.
Registered Trademarks:
- CareFusion
- Johnson & Johnson Corporation
LBL Number: LBL068956 R00 (2023-04)
Product Usage Instructions:
1. Ensure proper aseptic technique and sterile environment
before using the CDC-12123-XPN1A catheter.
2. Select an appropriate insertion site on the patient’s body,
considering factors such as accessibility and suitability for high
volume infusions.
3. Prepare the catheter by removing any packaging and inspecting
it for any visible defects or damages.
4. Attach the Raulerson Spring-Wire Introduction Syringe to the
catheter’s introducer needle.
5. Slowly and gently insert the introducer needle into the
selected site, following the recommended insertion technique.
6. Once the introducer needle is in place, carefully advance the
catheter over the wire guide until the desired length is
reached.
7. Remove the introducer needle and wire guide, ensuring that
the catheter remains securely in place.
8. Connect the injection needle (SafetyGlideTM1) to the
catheter’s injection port for administering medications or
fluids.
9. Prior to use, ensure that all connections are securely
tightened and free from leaks.
10. Monitor the patient closely during and after catheterization
for any signs of complications or adverse reactions.
11. Follow proper disposal guidelines for used catheters and
related medical waste.
6
NO
NO
CT
CT
CDC-12123-XPN1A
12 3 Fr.
Lumen
16 cm catheter length
.035 inch dia. spring-wire guide
Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions
Contents:
1: Three-Lumen Catheter: 12 Fr. (4.06 mm OD) x 16 cm Pressure Injectable Radiopaque Polyurethane with Blue FlexTip®, Extension Line Clamps
1: Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow® GlideWheelTM Wire Advancer
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
1: Injection Needle: SafetyGlideTM1 25 Ga. x 1″ (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm) 1: Pressure Transduction Probe 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow®
Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip
Syringe 1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm 1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm 3: 10 mL Luer-Lock Pre-Filled Saline Syringe 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep 2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with
Hi-Lite OrangeTM Tint
1: SharpsAway® II Locking Disposal Cup 1: SharpsAway® Disposal Cup 1: Maximal Barrier DrapeTM with 4″ fenestration 1: Towel 1: Needle Holder 1: Safety Scalpel: #11 1: Checklist/CLIP Sheet 1: Sterile Procedure Sign 1: Medication Label: 1% Lidocaine 2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm) 5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm) 1: Surgical Apparel: Impervious Gown 1: Dressing: I.V. Advanced 8.5 cm x 11.5 cm 1: Dressing: BIOPATCH®3 1: Transducer Cover: 14 cm x 147 cm 1: Surgical Apparel: Mask with Eye Shield 1: Surgical Apparel: Bouffant Cap 1: Suture: 3-0 Silk with Curved Needle 1: Tubing±: 20″ (50 cm) Extension 1: HemoHopper® Fluid Receptacle
1A trademark of Becton, Dickinson and Company.
±Precaution: Contains Phthalate: DEHP. Warning: The results of certain animal experiments have shown phthalates to be potentially toxic to reproduction. Proceeding from the present state of scientific knowledge, risks for male premature infants cannot be excluded in the case of long-term exposure or application. Medical products containing phthalates should be used only temporarily with pregnant women, nursing mothers, babies and infants. Not made with natural rubber latex. Store between 20 25°C (68 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.
Contraindications: The Multi-Lumen Acute Hemodialysis Catheter (AHDC) is not designed for long-term ( 30 days) hemodialysis or for insertion into thrombosed vessels.
2A registered trademark of CareFusion or one of its subsidiaries. 3A registered trademark of Johnson & Johnson Corporation.
LBL068956 R00 (2023-04)