CDC-16123-XPCN1A Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions
Product Information:
Product Name: CDC-16123-XPCN1A
Catheter Type: Pressure Injectable Three-Lumen Hemodialysis
Catheterization
Product Size: 12 3 Fr.
Catheter Length: 25 cm
Spring-Wire Guide Diameter: 0.035 inch
Contents:
- Catheter: 18 Ga. x 2-1/2 (6.35 cm) Radiopaque over 20 Ga. RW
Introducer Needle - Raulerson Spring-Wire Introduction Syringe
- Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2 (3.81 cm) and 5
mL Luer-Slip - Hi-Lite OrangeTM Tint
Trademarks: SafetyGlideTM is a trademark of Becton, Dickinson
and Company. Hi-Lite OrangeTM is a registered trademark of
CareFusion or one of its subsidiaries.
Contraindications: The Multi-Lumen Acute Hemodialysis Catheter
(AHDC) is not designed for long-term (30 days or more) hemodialysis
or for insertion into thrombosed vessels.
Product Usage Instructions:
- Ensure proper aseptic technique and hand hygiene before
handling the catheter and related equipment. - Select an appropriate insertion site and prepare the area by
cleaning with an antiseptic solution. - Assemble the Raulerson Spring-Wire Introduction Syringe to the
catheter and ensure a secure connection. - Insert the catheter into the desired vessel using the
spring-wire guide for guidance. - Once the catheter is properly positioned, remove the
spring-wire guide carefully. - Connect the catheter to the appropriate hemodialysis system or
infusion device. - Monitor the patient during the infusion process and follow the
recommended flow rates and protocols. - After use, properly dispose of the catheter and related
equipment according to local regulations and safety
guidelines.
Note: This product is not intended for long-term hemodialysis or
use in thrombosed vessels. Consult a healthcare professional for
alternative options.
For more detailed instructions and safety information, refer to
the complete user manual provided with the product.
6
NO
NO
CT
CT
CDC-16123-XPCN1A
12 3 Fr.
Lumen
25 cm catheter length
.035 inch dia. spring-wire guide
Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions
Contents:
1: Three-Lumen Catheter: 12 Fr. (4.06 mm OD) x 25 cm Pressure Injectable Radiopaque Polyurethane with Blue FlexTip®, Extension Line Clamps
1: Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow® GlideWheelTM Wire Advancer
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
1: Injection Needle: SafetyGlideTM1 25 Ga. x 1″ (2.54 cm) 1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm) 1: Pressure Transduction Probe 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow®
Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip
Syringe 1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm 1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm 3: 10 mL Luer-Lock Pre-Filled Saline Syringe 1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep 2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with
Hi-Lite OrangeTM Tint
1: SharpsAway® II Locking Disposal Cup 1: SharpsAway® Disposal Cup 1: Maximal Barrier DrapeTM with 4″ fenestration 1: Towel 1: Needle Holder 1: Safety Scalpel: #11 1: Checklist/CLIP Sheet 1: Sterile Procedure Sign 1: Medication Label: 1% Lidocaine 2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm) 5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm) 1: Surgical Apparel: Impervious Gown 1: Dressing: Tegaderm®3 CHG 3-1/2″ x 4-1/2″ (8.5 cm x 11.5 cm) 1: Transducer Cover: 14 cm x 147 cm 1: Surgical Apparel: Mask with Eye Shield 1: Surgical Apparel: Bouffant Cap 1: Suture: 3-0 Silk with Curved Needle 1: Tubing±: 20″ (50 cm) Extension 1: HemoHopper® Fluid Receptacle
1A trademark of Becton, Dickinson and Company. 2A registered trademark of CareFusion or one of its subsidiaries.
±Precaution: Contains Phthalate: DEHP. Warning: The results of certain animal experiments have shown phthalates to be potentially toxic to reproduction. Proceeding from the present state of scientific knowledge, risks for male premature infants cannot be excluded in the case of long-term exposure or application. Medical products containing phthalates should be used only temporarily with pregnant women, nursing mothers, babies and infants. Not made with natural rubber latex. Store between 20 25°C (68 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.
Contraindications: The Multi-Lumen Acute Hemodialysis Catheter (AHDC) is not designed for long-term ( 30 days) hemodialysis or for insertion into thrombosed vessels.
3A registered trademark of 3M Company.
LBL068961 R00 (2023-04)