The CBC-A air curtain cabinet is designed to create a clean
working environment on the workbench. It features a unique air
curtain that separates the operator from the process, giving
unlimited accessibility on the workbench. The air curtain cabinet
stands directly on the workbench and can be used for a variety of
applications, such as laboratory work, soldering, and gluing.
Product Content
The CBC-A air curtain cabinet comes with the following
components:
- Inner gable right
- Outer gable right
- Frame
- Front cap
- Air curtain gear (2 pcs)
- Lower backrail
- Inner gable left
- Outer gable left
- Back panel
- Top cover
- Power cord
- Screw set consisting of:
- Gable distance (2 pcs)
- Screw M6 (6 pcs)
- Barrel nut (8 pcs)
- Screw with nut M4 (2 pcs)
- Mounting tools
Technical Data
- Width x height x depth, internally: 1120 x 538 x 580 mm
- Width x height x depth, externally: 1275 x 625 x 760 mm
- Weight: 53 kg
- Sound level at 1 m, 200 m3/h: 49 dB(A)
- Power Supply: 110/240 V 50/60 Hz
- Consumption excl. lighting: 5 watt
- Glass tube fuse: 5×20 6,3 AT/250V T5
- Tube lighting (cold day light, colour temp 6500): 39W/865
min. - Extracted air volume: min. 180 – max. 230 m3/h
- Bench area required, minimum: 1200 x 750 mm + 50 mm free area
behind the cabinet - Warranty: 2 years
Safety Instructions
Do not modify the air curtain cabinet. Repairs must be done by
certified personnel.
Assembly Instructions
- Mount the left inner gable (7) on the frame (3), as shown in
the picture, with 3 pcs M6 screws (13) and 1 pc gable Spacer (12).
NOTE! Three Spacers are pre-assembled onto each gable.
- Mount the air curtain guide (5) and fasten the right inner
gable (1) in the same way as the left gable. - Mount the lower backrail (6) with 2 pcs M4 screw with nut (15)
in the track at the very bottom of the inner gables. - Put the cabinet on its feet and adjust them until the cabinet
stands stable. Max. adjustment 10 mm. NOTE! Do this before mounting
the outer gables as the nuts need to be tightened. - Loosen the cables fastened at the right inner gable and thread
them through the rubber grommets at the right inner gable.
Product Usage
When using the CBC-A air curtain cabinet, follow these
guidelines:
- Do not place the CBC-A in a draft, for example near doors,
windows, or supply air diffuser, as this can disrupt the air
curtain. - Keep your head outside the air curtain.
- The workpiece should be placed approximately 50 mm inside the
cabinet. - Blue represents clean air and yellow represents polluted
air.
Management
For low running costs and high mobility, connect the CBC-A to
mobile filter units from Weller. The air curtain can also be
connected to the central ventilation.
Troubleshooting
If you encounter any issues with the CBC-A air curtain cabinet,
do not modify it. Repairs must be done by certified personnel.
ASSEMBLING-& OPERATING MANUAL
CBC-A
Air curtain cabinet
T0055730300 / 12.2022
FOR A BETTER WORKBENCH ENVIRONMENT
Weller Tools GmbH
Apex Tool Group UK Ltd
Carl-Benz-Str. 2
Reg. in England, Company No. 14127816
74354 Besigheim, Germany 20 Farringdon Street, 8th Floor
Tel: +49 (0) 7143 580-0 London, EC4A 4AB, United Kingdom Fax: +49 (0) 7143 580-108
www.weller-tools.com
Table of contents
1. Introduction
2
2. Content
2
3. Safety instruction
3
4. Assembly instruction
3-7
5. Put into operation
8
6. Management
9
7. Troubleshooting
9
8. Technical data
10
9. Article number
10
10. Warranty
11
1. Introduction
CBC-A air curtain cabinet creates a clean working environment on the workbench.
A unique air curtain separates the operator from the process, giving unlimited accessibility on the workbench. The air curtain cabinet stands directly on the workbench and can be used for a variety of applications, such as laboratory work, soldering and gluing.
Connect the CBC-A to mobile filter units from Weller for low running costs and high mobility. The air curtain can also be connected to the central ventilation.
2. Content
1
Inner gable right
2
Outer gable right
3
Frame
4
Front cap
5
Air curtain gear (2 pcs)
6
Lower backrail
7
Inner gable left
8
Outer gable left
9
Back panel
10 Top cover
11 Power cord
Screw set consisting of: 12 Gable distance (2 pcs) 13 Screw M6 (6 pcs) 14 Barrel nut (8 pcs) 15 Screw with nut M4 (2 pcs)
Mounting tools 2
10. Warranty
Claims by the buyer for physical defects are time-barred after a period of one year from delivery to the buyer. This does not apply to claims by the buyer for indemnification in accordance with §§ 478, 479 BGB (German Federal Law Gazette). We shall only be liable for claims arising from a warranty furnished by us if the quality or durability warranty has been furnished by use in writing and using the term ,,Warranty”. The warranty shall be void if damage is due to improper use and if the device has been tampered with by unauthorised persons. Subject to technical alterations and amendments. For more information please visit www.weller-tools.com
11
8. Technical data CBC-A
Width x height x depth, internally Width x height x depth, externally Weight Sound level at 1 m, 200 m3/h Power Supply Consumption excl. lighting Glass tube fuse Tube lighting (cold day light, colour temp 6500) Extracted air volume Bench area required, minimum
Warranty
1120 x 538 x 580 mm 1275 x 625 x 760 mm 53 kg 49 dB(A) 110/240 V 50/60 Hz 5 watt 5×20 6,3 AT/250V T5 39W/865 min. 180 – max. 230 m3/h 1200 x 750 mm + 50 mm free area behind the cabinet 2 years
9. Article number
CBC-A-112-G02-G65-I2
Model CBC-A-112, with flourescent tube lighting, ESD-safe. Cabinet supplied with sheet top cover with one Ø160 mm connection (G02), sheet backside panel (G65) and tube lighting (I2).
3. Safety instructions
The CBC-A must not be exposed to a temperature over + 50°C, open fire or to condensed solvents.
4. Assembling instructions
Mount the left inner gable (7) on the frame (3), as shown in the picture, with 3 pcs M6 screws (13) and 1 pc gable Spacer (12). NOTE! Three Spacers are pre-assembled onto each gable.
3 7
10
3
Mount the air curtain guide (5) and fasten the right inner gable (1) in the same way as the left gable.
Mount the lower backrail (6) with 2 pcs M4 screw with nut (15) in the track at the very bottom of the inner gables.
6 6
Put the cabinet on its feets and adjust them until the cabinet stands stable. Max. adjustment 10 mm. NOTE! Do this before mounting the outer gables as the nuts need to be tightened.
Loosen the cables fastened at the right inner gable and thread them through the rubber grommets at the right inner gable.
4
5
6. Management
Do not place the CBC-A in a draught,
1
for example near doors, windows or supply air diffuser, as this can disrupt
the air curtain.
Keepchead outside the air curtain.
5
The workpiece should be placed
approx. 50 mm inside the cabinet.
Blue = Clean air Yellow = Polluted air
7. Troubleshooting
Do not modify the air curtain cabinet. Repairs must be done by certified personnell.
If the CBC-A does not work, check the following:
· the electricity supply is connected in a correct way. · the fuse is intact. It is placed beside the power supply. · the cabinet is placed according to the instructions. · extracted air volume is correct.
9
5. Put into operation
Place the air curtain cabinet on the workbench, approx. 100 mm from the front edge of the table. Minimum size of the table is 750×1200 mm. 50 mm free space is required behind the cabinet.
Pass the cable under the white wires and through the rubber grommet.
Connect the air curtain cabinet to the suction source.
NOTE! Neccessary air volume is min. 180 and max. 230 m3/h.
Connect the power cord (11) at the back of the cabinet.
11
Thread the double end of the cable into the hole at the front supporting leg and connect the socket to the upper blower.
Switch on the cabinet with the on/off switch.
Thread the single end of the cable into the hole at the back supporting leg and connect the lower blower.
Power sockets for connection of powered devices
8
5
Thread the cable from the tube lighting through the back hole in the left gable and mount the rubber grommet.
Connect socket.
Mount the top cover (10)… 10
… and back panel (9) by sliding them in the tracks.
9
6
Mount the front cap (4) by placing it in the upper track. Bow the cap slightly and press it in the lower track.
It is important that the cap is placed in both tracks.
Remove the yellow protection from the
spacers and mount the outer gables (2,
22
8) with 4 pcs barrel nuts (14) on each
side.
88
Make the mounting easier by fastening the barrel nuts slightly and tighten them when all are in its place.
The assembly is completed.
7