AR6100500GB Two Handle Lavatory Centerset Faucets
Product Information
The Two Handle Lavatory Centerset Faucets are designed for easy
installation and efficient water usage. It complies with California
water efficiency regulations, California Proposition 65, and the
Federal Safe Drinking Water Act. The faucet features a 1.2 GPM (4.5
L/min) flow rate and a durable finish.
Product Specifications
- Hole Size: 1.26 to 1.5 (32mm to 38mm)
- Pre-drilled hole size: 1.26 to 1.5 (32mm to 38mm)
- Max. Deck Thickness: 1.2″ (30mm)
Cleaning and Care
To clean the faucet, simply wipe gently with a damp cloth and
blot dry with a soft towel. Avoid using harsh abrasives or polish,
as they can damage the finish.
Product Usage Instructions
- Before installing the valves, clean the water pipe thoroughly
to avoid dirt and deposits. - Install the spout (1) O-ring (2), securing it with the washer
and nut (3). If the sink is uneven, use silicone under the
gasket. - Attach the flexible hoses under the hot and cold end
valves. - Make sure to attach the gasket to the base of the hot (1) and
cold (2) end valves. - Slide the hot (1) and cold (2) end valves with flexible hoses
(3) through the sink. - Place the washer (4) and metal plate (5) over the mounting stud
under the sink. Secure with the mounting nut (6). - Lock the mounting nut (6) into position by tightening the screw
(7). - Apply Teflon tape to the quick connect installation.
- Align the tabs and tabs on the quick connects. Push the quick
connects firmly upward and snap onto the receiving tube tab. Pull
down moderately to ensure each connection has been made. - Remove the washer (2), black gasket (4), and nut (5) from the
assembly. - Slide the washer (2) up to the underside of the flange (3).
Insert the flange (3) and washer (2) into the sink and secure with
the black gasket (4), washer, and nut (5) from underneath the
sink. - Put down and check the spring-loaded stopper (1).
- Connect the assembly to the drain.
- To flush debris from the plumbing system, remove the aerator by
hand. Run hot and cold water for one minute, then replace the
aerator. - Repeat the above steps for the other hose connection, ensuring
that the hose with the hot label is connected to the hot supply
valve and the other hose is connected to the cold supply
valve. - Flush the system and check for leaks by turning on the hot and
cold water supplies and flushing water lines for one minute. Check
all connections at arrows for leaks. Retighten if necessary, but do
not overtighten.
TWO HANDLE LAVATORY CENTERSET FAUCETS
You may need
1.2GPM 4.5L/min
For easy installation of your faucet you will need:
To READ ALL the instructions completely before beginning.
To READ ALL warnings, care, and maintenanceinformation.
With 1.2 gpm are compliant with California water effi ciency regulations, Complies with California Proposition 65 and with the Federal Safe Drinking Water Act.
washer 1.2gpm aeratot
In areas with extremely low water pressure causing the basin faucet water flow to be unsatisfactory ,
aeratot house
replace the 2.2 gpm aerator to improve the water flow in the basin faucet.
Cleaning and Care Care should be given to the cleaning of this product. Although its finish is extremely durable, It can be damaged by harsh abrasives or polish. To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.
1.26″ to 1.5″ (32mm to 38mm)
Hole Size
4″-16″ (100-400mm)
Ø1″(25)
4″ (100mm)
Pre drilled hole size : 1.26″ to 1.5″(32mm to 38mm)
Hole Size
Unsuitable sink size
1″(25mm) Hole Size
4.1″ (105mm)
7.3″ (186mm)
9.5″ to 21.5″ (240mm to 546mm)
4″ to 16″ (100mm to 406mm)
Hot
Cold
2.5″ (63mm)
1.2″(30mm) Max. deck
Thickness
M10x1mm
M14mm Ø26mm Ø26mm
3x 18
.
”
(45 mm)
3×1.1″ to 1.5″
(28mm to 38mm)
Hole Size
4.7″ (120mm)
Ø2.2″ (56mm)
1.1″ to 2.5″ (28 to 64mm)
24″(600mm)
9.5″(240mm) 8.7″(220mm)
9/16″
”
:”(
Hot Close
Cold Close
Min. 1.6″ (Ø41mm) Hole Dia
1 1/4” (Ø32mm)
Open
Open
OPERATION
· Double levers style handles · Maximum handle(s) rotation angle is 90° to full on · Rotate hot side counter clockwise to open (clockwise to close) · Rotate cold side clockwise to open (counter clockwise to close)
Notes
1
1 Before installing the valves, clean the water pipe thoroughly to avoid dirt and deposits.
1
2 3
Install spout (1) O-ring (2) , Secure with washer and nut (3). Note: If sink is uneven, use silicone under the gasket.
2
Attach flexible hoses under the
H
C
hot and cold end valves.
3
4
1
H 3
2 C
4
5
7
6
1.Make sure attach the gasket to the base of hot (1) and cold (2) end valves. 2.Slide hot (1) and cold (2) end valves with flexible hoses (3) through sink. 3.Place washer(4) and metal plate(5) over mountingstud under sink. Secure with mounting nut(6). 4.Lock mounting nut(6) into position by tightening screw (7).
NOT WITH apply teflon tape to the quick connect installation.
Align tabs and tabs on quick connects . Push quick connects firmly upward and snap onto receiving tube tab . Pull down moderately to ensure each connection has been made.
5
1
2 3
4 5
6 1.
1.Remove the washer (2) , black gasket (4) and nut (5) from the assembly. 2.Slide washer (2) up to underside of flange (3). Insert flange (3) and washer (2) into sink and secure with the black gasket (4) washer and nut (5) from underneath the sink. 3.Put down and check the Springloaded stopper (1). 4. Connect assembly to drain.
7
7
2. 3.
To flush debris from the plumbing system: 1.Remove the aerator by hand. 2.Run hot and cold water for one minute. 3.Replace the aerator.
Repeat for other hose connection making sure the hose with the hot label is connected to the hot supply valve and the other hose is connected to the cold supply valve. FLUSH SYSTEM/CHECK FOR LEAKS. Turn on hot and cold water supplies and flush water lines for one minute. Check all connections at arrows for leaks. Retighten if necessary, but do not overtighten.