Arcora Ar7104300c-43 Wall Mount Commercial Kitchen Faucet Instruction Manual

AR7104300C-43 Wall Mount Commercial Kitchen Faucet

Product Information

This product is a pre-rinse faucet designed for commercial use.
It is available in three different models: 43 Pre Rinse Faucets, 21
Mini Pre Rinse Faucets, and 47 Pre Rinse Faucets. The faucet
features G1/2 male and M22x1 female connections, and is compatible
with NPT1/2 supply lines. It has a maximum pressure of 6.3 (160)
and a flow rate of 1.8 gpm, which complies with California water
efficiency regulations. The faucet also meets California
Proposition 65 and Federal Safe Drinking Water Act
requirements.

Product Usage Instructions

  1. Attach supply lines (not included) to the faucet.
  2. Connect the two flanges (3) into the two inlets (5), and screw
    them tightly.
  3. Connect the body (1) to the flanges (3), ensuring that the
    gaskets (2) are inside. The flanges (3) are adjustable inlets.
    Unscrew the hexagon nut (4) on the flange (3), rotate the flange
    (3) to adjust the distance from 7 3/4 to 8 1/4, and then screw the
    hexagon nut back tightly.
  4. Turn out the hexagon (6) and use the hexagon nut to lock the
    faucet and sink.
  5. Insert the short riser (2) into the body (1) and screw the
    thread (3) tightly. Connect the other side of the shorter riser (2)
    to the add-on faucet (5) and screw the thread (4) tightly.
  6. Put the swing nozzle (3) into the add-on faucet (1) and screw
    the nut (2).
  7. Connect the longer riser (3) to the other side of the add-on
    faucet (1) and screw the thread (2) tightly.
  8. Fix one side of the wall bracket (4) onto the wall.
  9. Unscrew the other side of the wall bracket (1), insert the
    longer riser inside (5), and then screw the other side of the
    bracket (1) after adjusting the height of the wall bracket.
  10. Insert the brass tube (3) into the wall bracket (4), and use
    the Allen wrench to fix the brass tube (3) and the bracket
    (4).
  11. Ensure that the distance from the wall does not exceed 160mm.
    Cut the brass tube (3) if necessary to adjust the faucet’s distance
    from the wall.

43″ Pre Rinse Faucets

inch(mm)

G1/2 Male

40″(1016)

43″(1100)

M22x1 Female

MAX 6.3″ (160)

10″(250)

6″(155)

NPT1/2
Attach supply lines (not included).

2.8″(70)

8 1/4″(209.5)
7 3/4″(197)
8 inches adjustable center hole distance Wall mounted faucet using a pair of G1/2″ female inlets with 2″flanges. those inlets can adjust from 7 3/4″(197mm) to 8 1/4″(209.5), allowing you to fit them directly onto your facility’s water lines with ease.
With 1.8 gpm are compliant with California water effi ciency regulations,Complies with California Proposition 65 and with the Federal Safe Drinking Water Act.

11″(280) 12.2″(310) 21″(533) 11″(280) 2.4″ (60) 25″(635) 11.8″(300) 8.6″(218)

21″ Mini Pre Rinse Faucets

25″ Mini Pre Rinse Faucets

19″(482)
M22x1 Female

MAX6.3″ (160)

10″(250)

NPT1/2

2.8″(70)

19″(482)

MAX6.3″ (160)

9.6″(245)

NPT1/2

2.8″(70)

36″ Pre Rinse Faucets

47″ Pre Rinse Faucets

36″(915)

40″(1016)

MAX 6.3″ (160)

10″(250)

2.8″(70)

11″(280) 7.7″(195)

47″(1194)

NPT1/2

40″(1016)
MAX 6.3″ (160)
12″(300) 2.8″(70)

NPT1/2

11.8″(300) 16.2″(410)

6 5 4 32
1

1.Connect the two flanges (3) into the two inlets (5) . Screw them tightly.
2.Connect the body (1) to the flanges (3), do remember the gaskets (2) inside. The two flanges (3) are adjustable inlets. Unscrew the hexagon nut (4) on the flange (3) , rotate the flange(3) to the right the distance and screw the hexagon thread back tightly. You can adjust the distance from 7 3/4″to8 1/4″.
3.Turn out the hexagon (6), Use the hexagon nut to lock the faucet and sink

4

5

3 2

4.Insert the short riser (2) to the body (1) , Screw the thread (3) tightly. Connect the other side of the shorter riser (2) with the add-on faucet (5), Screw the thread (4) tightly.

1
3 3
2 2 1
1

5.Put the swing nozzle (3) into the add-on faucet (1), screw the nut (2).

6.connect the longer riser (3) with the other side of the add-on faucet (1), Screw the thread (2) tightly.

7.Fix one side of the wall bracket (4) onto the wall .
8.Unscrew the other side of the wall bracket (1) and put the longer riser inside (5). Screw the other side of the bracket (1) after adjusting the height of the wall bracket.
9.Insert the brass tube (3) into wall bracket (4),use the Allen wrench to fix the brass tube (3) and the bracket (4).

4

3

2

160mm

1

5

Distance from wall MAX 160mm. Cut the brass tube (3) if the faucet to the wall is <160mm.

10.Screw the hook (2) after adjusting the height with the screwdriver.

5

6

4

7

3

8

2 1

11.Connect the other side of the longer riser (1)to the flexible hose(5) , do remember the gasket (3) inside and the connector (4) must be tightly screwed. Adjusting the height of the bracket(2). 11.Connect the other side of the fleible tube (6) with the spray(8) , do remember the gasket (7) inside .

FLUSH SYSTEM/CHECK FOR LEAKS. Turn on hot and cold water supplies and flush water lines for one minute. Check all connections at arrows for leaks. Retighten if necessary, but do not overtighten.