BEEZOOM740 7×40W LED Moving Head
BEEZOOM740
User Manual
Table of Contents
Statement:
The product has a well capability and intact packing when
leaving the factory. All users should comply with warning items and
the manual. Any misuse causing damages is not included in our
guarantee, and we cannot be responsible for any malfunction &
problem owing to ignoring the manual.
1 Safety Instructions
- Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive this
instruction booklet. - Unpack and check carefully for any transportation damage before
using the unit. - Before operating, ensure that the voltage and frequency of
power supply match the power requirements of the unit. - It’s important to ground the yellow/green conductor to earth to
avoid electric shock. - The unit is for indoor use only. Use only in a dry
location. - The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure that no
ventilation slots are blocked. - Disconnect main power before replacement or servicing.
- Make sure there are no flammable materials close to the unit
while operating as it is a fire hazard. - Use safety cable when fixing this unit. DO NOT handle the unit
by taking its head only, but always by taking its base. - Maximum ambient temperature is Ta: 40. DO NOT operate it where
the temperature is higher than this. Unit surface temperature may
reach up to 85. DO NOT touch the housing bare-hand during its
operation. Turn off the power and allow about 15 minutes for the
unit to cool down before replacing or servicing. - In the event of a serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself. Repairs
carried out by unskilled people can lead to damage or malfunction.
Please contact the nearest authorized technical assistance center.
Always use the same type spare parts. - DO NOT touch any wire during operation as high voltage might be
causing electric shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do
not expose the unit to rain or moisture. DO NOT open the unit
within five minutes after switching off. The housing, the lenses,
or the ultraviolet filter must be replaced if they are visibly
damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open
the housing or attempt any repairs yourself. In the unlikely event
your unit may require service, please contact your nearest
dealer.
2 Technical Specifications
3 How To Control The Unit
The DMX512 is widely used in intelligent lighting control, with
a DMX 512 controller. Connect several lights together, dmx in and
dmx out, 3 pin XLR connectors: Pin 1: GND, Pin 2: Negative signal
(-), Pin 3: Positive signal (+).
Display:
- MENU: To select the programming functions
- DOWN: To go backward in the selected
functions - UP: To go forward in the selected
functions - ENTER: To confirm the selected functions
Set DMX Address Code:
Press Menu to Set DMX Address, and press ENTER keys to enter
into Show Set DMX Address DMX Address:001, Press the UP and DOWN
keys to amended. Press ENTER keys to save and Exit, Press the MENU
Keys does not save and Exit.
Product Usage Instructions
- Ensure that the unit is unpacked and checked for any
transportation damage before using it. - Before operating, ensure that the voltage and frequency of
power supply match the power requirements of the unit. It’s
important to ground the yellow/green conductor to earth to avoid
electric shock. - The unit is for indoor use only. Use only in a dry
location. - The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure that no
ventilation slots are blocked. - Disconnect main power before replacement or servicing.
- Make sure there are no flammable materials close to the unit
while operating as it is a fire hazard. - Use safety cable when fixing this unit. DO NOT handle the unit
by taking its head only, but always by taking its base. - Maximum ambient temperature is Ta: 40. DO NOT operate it where
the temperature is higher than this. Unit surface temperature may
reach up to 85. DO NOT touch the housing bare-hand during its
operation. Turn off the power and allow about 15 minutes for the
unit to cool down before replacing or servicing. - In the event of a serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself. Repairs
carried out by unskilled people can lead to damage or malfunction.
Please contact the nearest authorized technical assistance center.
Always use the same type spare parts. - DO NOT touch any wire during operation as high voltage might
cause electric shock. - To prevent or reduce the risk of electrical shock or fire, do
not expose the unit to rain or moisture. DO NOT open the unit
within five minutes after switching off. The housing, the lenses,
or the ultraviolet filter must be replaced if they are visibly
damaged. - There are no user serviceable parts inside the unit. DO NOT
open the housing or attempt any repairs yourself. In the unlikely
event your unit may require service, please contact your nearest
dealer. - Connect several lights together, DMX in and DMX out, 3 pin XLR
connectors: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive
signal (+). - Press Menu to Set DMX Address, and press ENTER keys to enter
into Show Set DMX Address DMX Address:001, Press the UP and DOWN
keys to amended. Press ENTER keys to save and Exit, Press the MENU
Keys does not save and Exit.
BEEZOOM740
7×40 W LED Moving Head
USER MANUAL
TABLE OF CONTENTS
Safety Instructions……………………………………………………………………………………….2 Technical Specifications……………………………………………………………………………….4 How To Control The Unit…………………………………………………………………………….. 6 Channel………………………………………………………………………………………………………. 8 Trouble shooting……………………………………………………………………………………….. 13 Fixture Cleaning…………………………………………………………………………………………14
Statement
The product has well capability and intact packing when leave factory. All of the user should comply with warning item and manual, any misuse cause of the damages are not included in our guarantee, and also can not be responsible for any malfunction & problem owing to ignore the manual.
1 Safety Instructions
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instructionbooklet. Unpack and check carefully there is no transportation damage before using the unit. Before operating, ensure that the voltage and frequency of power supply match the power
requirements of the unit. It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. The unit is for indoor use only. Use only in a dry location. The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.
Be sure that no ventilation slots are blocked. Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as it is fire hazard. Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but always by taking its base.
Maximum ambient temperature is Ta: 40. DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85. DO NOT touch the housing bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving.
In the event of serious operating problem, stop using the unit immediately.Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
DO NOT touch any wire during operation as high voltage might be causing electric shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.
2 Technical Specifications
Light Sources: 7x40W RGBW Original LED Power Voltage: AC 100-240V, 50/60Hz, 500w Single LED power: 40W Color: RGBW automatic correction 16.7 million pixels Electronic dimmer:0100% linear Control DMX Channel: 23/35/51 Channel Control Modes: DMX512 Software Upgrade: Firmware update via DMX link Pan/Tilt Pan/Tilt: 540°
Construction Display: LCD Display Data In/Out socket: 3-pin XLR sockets Power Socket: Powercon in/out Protection Rating: IP20 Features Motorized liner zoom system, zoom range: 4.5°~45° Outstanding color macro effect,CTO,Kaleido effects,led single controlled Dimmer: 0~100% smooth dimming Variable strobe effects Fast, quiet operation and flicker free / 270° Pan/Tilt Resolution: 16 bit
3
3 How To Control The Unit
The DMX512 is widely used in intelligent lighting control,with a DMX 512 controller.connect several lights together,dmx in and dmx out, 3 pin XLR connectors: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
Display:
MENU To select the programming functions DOWN To go backward in the
selected functions uP
To go forward in the selected functions ENTER
To
confirm the selected functions
Set DMX Address Code
Press “Menu” to “Set DMX Address”,and press”ENTER” keys to enter into Show “Set DMX Address DMX Address:001”,Press the “UP and DOWN” keys to amended Press “ENTER”keys to save and Exit,Press the”MENU”Keys does not save and Exit
4
Menu
DmxAddr Fix Set
Manual
001 – 512 Ch Mode Run Mode Pan Inv Tilt Inv Pan Pan Fine Tilt Tilt Fine . . .
TimeInfo
Fix Info
SenSor
STD/HIS DMX/Host Close/Open Close/Open 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 Cur Time Show Time PowerCnt Pan Tilt Zoom Temp Fan
xxxh xxxh xxx OK/NG OK/NG OK/NG OK/NG OK/NG
5
TempInfo
Soft Ver
Home Set
FixReset Display
Password Pan Tilt Zoom Red Green Blue White Reset
Factory Language DispFlip DispMode
Temprat FanSpeed Panel Motor 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 Cance/Run Cance/Run EN/CH Open/Close Show/60s
xxx C xxxx RPM Vx.xxx Vx.xxx
DMX channel´s functions and values (23/35/51 DMX channels):
Channel list(23 channels)
chs
function
DMX value
description
1
X
0-255
0-540 degree
2
X fine
0-255
16 bit
3
Y
0-255
0-205 degree
4
Y fine
0-255
16 bit
5
XY speed
0-255
Fast-slow
6
zoom
0-255
Angle from small-big
0-127
0~60 degree
7
rotating
128-191
Antiwise fast-slow
200-255
Forward slow-fast
8
dimmer
0-255
From dark-bright
0-3
on
9
strobe
4-200
Synchronous strobe from slow-fast
201-215
Random strobe in low speed
6
10
R dimmer
11
G dimmer
12
B dimmer
13
W dimmer
14
CT
15
wash
16
Static effect
17 Dynamic effect
18
Dynamic effect speed
19 Background R
20 Background G
21 Background B
22 Background W
23
reset
216-234 235-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-127 128-255 0-255 0-255 0-255 0-255 0-199 200-205 206-255
Random strobe in middle speed Random strobe in high speed
From dark-bright From dark-bright From dark-bright From dark-bright Linear CT control Inner color gradual change 5 no. One effect 5 no. One effect Forward from fast-slow Reverse from slow-fast
Dark-bright Dark-bright Dark-bright Dark-bright
invalid Reset after 5 seconds
invalid
Channel list(35 channels)
chs
function DMX value
description
1
red
0-255
Red dimmer
2
Red fine
0-255
Red dimmer fine
3
green
0-255
Green dimmer
4
Green fine
0-255
Green dimmer fine
5
blue
0-255
Blue dimmer
6
Blue fine
0-255
Blue dimmer fine
7
white
0-255
White dimmer
8
White fine
0-255
White dimmer fine
9
CT
0-255
Linear CT control
10 Color Macro 0-255
Color Macro function
0-3
off
11
strobe
4-103
Synchronous strobe slow-fast 1HZ25HZ
104-107
on
7
108-207
208-212
213-225
226-238
239-251
252-255
12
dimmer
0-255
13 Dimmer fine 0-255
14
pan
0-255
15
Pan fine
0-255
16
tilt
0-255
17
Tilt fine
0-255
18
function
0-255
0-199
19
reset
200-205
206-255
20
zoom
0-255
0-127
21 Lens rotating 128-191
192-255
22
pattern
0-255
23 Pattern speed 0-255
24
Pattern effect fade
0-255
25 Pattern effect R 0-255
26 Pattern effect G 0-255
27 Pattern effect B 0-255
28 Pattern effect W 0-255
29 Pattern dimmer 0-255
30
Background dimmer
0-255
31
Pattern transition
0-255
32 Pattern angle 0-255
33 Prospect strobe 0-255
34
Background strobe
0-255
35 Background 0-255
Divide strobe from slow-fast 1HZ25HZ on
Random strobe in low speed Random strobe in middle speed Random strobe in high speed
on Linear dimmer from dark-bright
Dimmer fine pan
Pan fine tilt
Tilt fine
invalid Reset after 5 seconds
invalid zoom 0~60 degree Forward limitless rotate Reverse limitless rotate Pattern rotate Pattern speed
Pattern 0-100% dimmer Background 0-100% dimmer
Pattern design Prospect strobewith 11 chs Background strobewith 11 chs
8
selection
Channel list(51 channels)
chs
function
DMX value
1
X
0-255
2
X fine
0-255
3
Y
0-255
4
Y fine
0-255
5
XY speed
0-255
6
zoom
0-255
0-127
7
rotating
128-191
200-255
8
dimmer
0-255
0-3
4-200
9
strobe
201-215
216-234
235-255
10
R dimmer
0-255
11
G dimmer
0-255
12
B dimmer
0-255
13
W dimmer
0-255
14
CT
0-255
15
Wash
0-255
16
Static effect
0-255
17 Dynamic effect
0-255
18
Dynamic effect speed
0-127 128-255
19 Background R
0-255
20 Background G
0-255
21 Background B
0-255
22 Background W
0-255
0-199
23
reset
200-205
206-255
description 0-540 degree
16 bit 0-205 degree
16 bit Fast-slow Small-big 0~60 degree Forward fast-slow Reverse slow-fast Dark-bright
on Synchronous strobe slow-fast Random strobe in low speed Random strobe in midlle speed Random strobe in high speed
Linear CT control
5 no. One effect 5 no. One effect Forward fast-slow Reverse slow-fast
Dark-bright Dark-bright Dark-bright Dark-bright
invalid Reset after 5s
invalid
9
24 R1 LED dimmer
25 G1 LED dimmer
26 B1 LED dimmer
27 W1 LED dimmer
…
…
…
…
48 R7 LED dimmer
49 G7 LED dimmer
50 B7 LED dimmer
51 W7 LED dimmer
0-255 0-255 0-255 0-255 …… …… 0-255 0-255 0-255 0-255
R1 LED dimmer G1 LED dimmer B1 LED dimmer W1 LED dimmer
…… …… R7 LED dimmer G7 LED dimmer B7 LED dimmer W7 LED dimmer
10
4 Trouble shooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
· The unit does not work, no light and the fan does not work
· Check the connection of power and main fuse. · Measure the mains voltage on the main connector. · Check the power on LED.
· Not responding to DMX controller
· DMX LED should be on. If not, check DMX connectors, cables to see if link properly. · If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. · If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one. · Try to use another DMX controller. · Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference
to DMX interface circuit.
· One of the channels is not working well
· The stepper motor might be damaged or the cable connected to the PCB is broken.
6. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding cancause greateraccumulationofdirtontheunit’soptics. 1. Clean with soft cloth using normal glass cleaning fluid. 2. Always dry the parts carefully. 3. Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.