Sistema Beezoom740 7×40w Led Moving Head User Manual

BEEZOOM740 7×40W LED Moving Head

BEEZOOM740

User Manual

Table of Contents

Statement:

The product has a well capability and intact packing when
leaving the factory. All users should comply with warning items and
the manual. Any misuse causing damages is not included in our
guarantee, and we cannot be responsible for any malfunction &
problem owing to ignoring the manual.

1 Safety Instructions

  • Please keep this User Guide for future consultation. If you
    sell the unit to another user, be sure that they also receive this
    instruction booklet.
  • Unpack and check carefully for any transportation damage before
    using the unit.
  • Before operating, ensure that the voltage and frequency of
    power supply match the power requirements of the unit.
  • It’s important to ground the yellow/green conductor to earth to
    avoid electric shock.
  • The unit is for indoor use only. Use only in a dry
    location.
  • The unit must be installed in a location with adequate
    ventilation, at least 50cm from adjacent surfaces. Be sure that no
    ventilation slots are blocked.
  • Disconnect main power before replacement or servicing.
  • Make sure there are no flammable materials close to the unit
    while operating as it is a fire hazard.
  • Use safety cable when fixing this unit. DO NOT handle the unit
    by taking its head only, but always by taking its base.
  • Maximum ambient temperature is Ta: 40. DO NOT operate it where
    the temperature is higher than this. Unit surface temperature may
    reach up to 85. DO NOT touch the housing bare-hand during its
    operation. Turn off the power and allow about 15 minutes for the
    unit to cool down before replacing or servicing.
  • In the event of a serious operating problem, stop using the
    unit immediately. Never try to repair the unit by yourself. Repairs
    carried out by unskilled people can lead to damage or malfunction.
    Please contact the nearest authorized technical assistance center.
    Always use the same type spare parts.
  • DO NOT touch any wire during operation as high voltage might be
    causing electric shock.

Warning:

To prevent or reduce the risk of electrical shock or fire, do
not expose the unit to rain or moisture. DO NOT open the unit
within five minutes after switching off. The housing, the lenses,
or the ultraviolet filter must be replaced if they are visibly
damaged.

Caution:

There are no user serviceable parts inside the unit. DO NOT open
the housing or attempt any repairs yourself. In the unlikely event
your unit may require service, please contact your nearest
dealer.

2 Technical Specifications

3 How To Control The Unit

The DMX512 is widely used in intelligent lighting control, with
a DMX 512 controller. Connect several lights together, dmx in and
dmx out, 3 pin XLR connectors: Pin 1: GND, Pin 2: Negative signal
(-), Pin 3: Positive signal (+).

Display:

  • MENU: To select the programming functions
  • DOWN: To go backward in the selected
    functions
  • UP: To go forward in the selected
    functions
  • ENTER: To confirm the selected functions

Set DMX Address Code:

Press Menu to Set DMX Address, and press ENTER keys to enter
into Show Set DMX Address DMX Address:001, Press the UP and DOWN
keys to amended. Press ENTER keys to save and Exit, Press the MENU
Keys does not save and Exit.

Product Usage Instructions

  1. Ensure that the unit is unpacked and checked for any
    transportation damage before using it.
  2. Before operating, ensure that the voltage and frequency of
    power supply match the power requirements of the unit. It’s
    important to ground the yellow/green conductor to earth to avoid
    electric shock.
  3. The unit is for indoor use only. Use only in a dry
    location.
  4. The unit must be installed in a location with adequate
    ventilation, at least 50cm from adjacent surfaces. Be sure that no
    ventilation slots are blocked.
  5. Disconnect main power before replacement or servicing.
  6. Make sure there are no flammable materials close to the unit
    while operating as it is a fire hazard.
  7. Use safety cable when fixing this unit. DO NOT handle the unit
    by taking its head only, but always by taking its base.
  8. Maximum ambient temperature is Ta: 40. DO NOT operate it where
    the temperature is higher than this. Unit surface temperature may
    reach up to 85. DO NOT touch the housing bare-hand during its
    operation. Turn off the power and allow about 15 minutes for the
    unit to cool down before replacing or servicing.
  9. In the event of a serious operating problem, stop using the
    unit immediately. Never try to repair the unit by yourself. Repairs
    carried out by unskilled people can lead to damage or malfunction.
    Please contact the nearest authorized technical assistance center.
    Always use the same type spare parts.
  10. DO NOT touch any wire during operation as high voltage might
    cause electric shock.
  11. To prevent or reduce the risk of electrical shock or fire, do
    not expose the unit to rain or moisture. DO NOT open the unit
    within five minutes after switching off. The housing, the lenses,
    or the ultraviolet filter must be replaced if they are visibly
    damaged.
  12. There are no user serviceable parts inside the unit. DO NOT
    open the housing or attempt any repairs yourself. In the unlikely
    event your unit may require service, please contact your nearest
    dealer.
  13. Connect several lights together, DMX in and DMX out, 3 pin XLR
    connectors: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive
    signal (+).
  14. Press Menu to Set DMX Address, and press ENTER keys to enter
    into Show Set DMX Address DMX Address:001, Press the UP and DOWN
    keys to amended. Press ENTER keys to save and Exit, Press the MENU
    Keys does not save and Exit.

BEEZOOM740
7×40 W LED Moving Head
USER MANUAL

TABLE OF CONTENTS
Safety Instructions……………………………………………………………………………………….2 Technical Specifications……………………………………………………………………………….4 How To Control The Unit…………………………………………………………………………….. 6 Channel………………………………………………………………………………………………………. 8 Trouble shooting……………………………………………………………………………………….. 13 Fixture Cleaning…………………………………………………………………………………………14
Statement
The product has well capability and intact packing when leave factory. All of the user should comply with warning item and manual, any misuse cause of the damages are not included in our guarantee, and also can not be responsible for any malfunction & problem owing to ignore the manual.
1 Safety Instructions
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instructionbooklet. Unpack and check carefully there is no transportation damage before using the unit. Before operating, ensure that the voltage and frequency of power supply match the power
requirements of the unit. It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. The unit is for indoor use only. Use only in a dry location. The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.
Be sure that no ventilation slots are blocked. Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as it is fire hazard. Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but always by taking its base.
Maximum ambient temperature is Ta: 40. DO NOT operate it where the temperature is higher than this Unit surface temperature may reach up to 85. DO NOT touch the housing bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving.
In the event of serious operating problem, stop using the unit immediately.Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
DO NOT touch any wire during operation as high voltage might be causing electric shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.

Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. And make sure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.
2 Technical Specifications
Light Sources: 7x40W RGBW Original LED Power Voltage: AC 100-240V, 50/60Hz, 500w Single LED power: 40W Color: RGBW automatic correction 16.7 million pixels Electronic dimmer:0100% linear Control DMX Channel: 23/35/51 Channel Control Modes: DMX512 Software Upgrade: Firmware update via DMX link Pan/Tilt Pan/Tilt: 540°
Construction Display: LCD Display Data In/Out socket: 3-pin XLR sockets Power Socket: Powercon in/out Protection Rating: IP20 Features Motorized liner zoom system, zoom range: 4.5°~45° Outstanding color macro effect,CTO,Kaleido effects,led single controlled Dimmer: 0~100% smooth dimming Variable strobe effects Fast, quiet operation and flicker free / 270° Pan/Tilt Resolution: 16 bit
3

3 How To Control The Unit
The DMX512 is widely used in intelligent lighting control,with a DMX 512 controller.connect several lights together,dmx in and dmx out, 3 pin XLR connectors: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)

Display:

MENU To select the programming functions DOWN To go backward in the

selected functions uP

To go forward in the selected functions ENTER

To

confirm the selected functions

Set DMX Address Code
Press “Menu” to “Set DMX Address”,and press”ENTER” keys to enter into Show “Set DMX Address DMX Address:001”,Press the “UP and DOWN” keys to amended Press “ENTER”keys to save and Exit,Press the”MENU”Keys does not save and Exit

4

Menu

DmxAddr Fix Set
Manual

001 – 512 Ch Mode Run Mode Pan Inv Tilt Inv Pan Pan Fine Tilt Tilt Fine . . .

TimeInfo

Fix Info

SenSor

STD/HIS DMX/Host Close/Open Close/Open 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 Cur Time Show Time PowerCnt Pan Tilt Zoom Temp Fan

xxxh xxxh xxx OK/NG OK/NG OK/NG OK/NG OK/NG

5

TempInfo

Soft Ver

Home Set
FixReset Display

Password Pan Tilt Zoom Red Green Blue White Reset
Factory Language DispFlip DispMode

Temprat FanSpeed Panel Motor 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 0 – 255 Cance/Run Cance/Run EN/CH Open/Close Show/60s

xxx C xxxx RPM Vx.xxx Vx.xxx

DMX channel´s functions and values (23/35/51 DMX channels):

Channel list(23 channels)

chs

function

DMX value

description

1

X

0-255

0-540 degree

2

X fine

0-255

16 bit

3

Y

0-255

0-205 degree

4

Y fine

0-255

16 bit

5

XY speed

0-255

Fast-slow

6

zoom

0-255

Angle from small-big

0-127

0~60 degree

7

rotating

128-191

Antiwise fast-slow

200-255

Forward slow-fast

8

dimmer

0-255

From dark-bright

0-3

on

9

strobe

4-200

Synchronous strobe from slow-fast

201-215

Random strobe in low speed

6

10

R dimmer

11

G dimmer

12

B dimmer

13

W dimmer

14

CT

15

wash

16

Static effect

17 Dynamic effect

18

Dynamic effect speed

19 Background R

20 Background G

21 Background B

22 Background W

23

reset

216-234 235-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-255 0-127 128-255 0-255 0-255 0-255 0-255 0-199 200-205 206-255

Random strobe in middle speed Random strobe in high speed
From dark-bright From dark-bright From dark-bright From dark-bright Linear CT control Inner color gradual change 5 no. One effect 5 no. One effect Forward from fast-slow Reverse from slow-fast
Dark-bright Dark-bright Dark-bright Dark-bright
invalid Reset after 5 seconds
invalid

Channel list(35 channels)

chs

function DMX value

description

1

red

0-255

Red dimmer

2

Red fine

0-255

Red dimmer fine

3

green

0-255

Green dimmer

4

Green fine

0-255

Green dimmer fine

5

blue

0-255

Blue dimmer

6

Blue fine

0-255

Blue dimmer fine

7

white

0-255

White dimmer

8

White fine

0-255

White dimmer fine

9

CT

0-255

Linear CT control

10 Color Macro 0-255

Color Macro function

0-3

off

11

strobe

4-103

Synchronous strobe slow-fast 1HZ25HZ

104-107

on

7

108-207

208-212

213-225

226-238

239-251

252-255

12

dimmer

0-255

13 Dimmer fine 0-255

14

pan

0-255

15

Pan fine

0-255

16

tilt

0-255

17

Tilt fine

0-255

18

function

0-255

0-199

19

reset

200-205

206-255

20

zoom

0-255

0-127

21 Lens rotating 128-191

192-255

22

pattern

0-255

23 Pattern speed 0-255

24

Pattern effect fade

0-255

25 Pattern effect R 0-255

26 Pattern effect G 0-255

27 Pattern effect B 0-255

28 Pattern effect W 0-255

29 Pattern dimmer 0-255

30

Background dimmer

0-255

31

Pattern transition

0-255

32 Pattern angle 0-255

33 Prospect strobe 0-255

34

Background strobe

0-255

35 Background 0-255

Divide strobe from slow-fast 1HZ25HZ on
Random strobe in low speed Random strobe in middle speed Random strobe in high speed
on Linear dimmer from dark-bright
Dimmer fine pan
Pan fine tilt
Tilt fine
invalid Reset after 5 seconds
invalid zoom 0~60 degree Forward limitless rotate Reverse limitless rotate Pattern rotate Pattern speed
Pattern 0-100% dimmer Background 0-100% dimmer
Pattern design Prospect strobewith 11 chs Background strobewith 11 chs

8

selection

Channel list(51 channels)

chs

function

DMX value

1

X

0-255

2

X fine

0-255

3

Y

0-255

4

Y fine

0-255

5

XY speed

0-255

6

zoom

0-255

0-127

7

rotating

128-191

200-255

8

dimmer

0-255

0-3

4-200

9

strobe

201-215

216-234

235-255

10

R dimmer

0-255

11

G dimmer

0-255

12

B dimmer

0-255

13

W dimmer

0-255

14

CT

0-255

15

Wash

0-255

16

Static effect

0-255

17 Dynamic effect

0-255

18

Dynamic effect speed

0-127 128-255

19 Background R

0-255

20 Background G

0-255

21 Background B

0-255

22 Background W

0-255

0-199

23

reset

200-205

206-255

description 0-540 degree
16 bit 0-205 degree
16 bit Fast-slow Small-big 0~60 degree Forward fast-slow Reverse slow-fast Dark-bright
on Synchronous strobe slow-fast Random strobe in low speed Random strobe in midlle speed Random strobe in high speed
Linear CT control
5 no. One effect 5 no. One effect Forward fast-slow Reverse slow-fast
Dark-bright Dark-bright Dark-bright Dark-bright
invalid Reset after 5s
invalid

9

24 R1 LED dimmer

25 G1 LED dimmer

26 B1 LED dimmer

27 W1 LED dimmer

48 R7 LED dimmer

49 G7 LED dimmer

50 B7 LED dimmer

51 W7 LED dimmer

0-255 0-255 0-255 0-255 …… …… 0-255 0-255 0-255 0-255

R1 LED dimmer G1 LED dimmer B1 LED dimmer W1 LED dimmer
…… …… R7 LED dimmer G7 LED dimmer B7 LED dimmer W7 LED dimmer

10

4 Trouble shooting
Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:
· The unit does not work, no light and the fan does not work
· Check the connection of power and main fuse. · Measure the mains voltage on the main connector. · Check the power on LED.
· Not responding to DMX controller
· DMX LED should be on. If not, check DMX connectors, cables to see if link properly. · If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. · If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one. · Try to use another DMX controller. · Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference
to DMX interface circuit.
· One of the channels is not working well
· The stepper motor might be damaged or the cable connected to the PCB is broken.
6. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding cancause greateraccumulationofdirtontheunit’soptics. 1. Clean with soft cloth using normal glass cleaning fluid. 2. Always dry the parts carefully. 3. Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
11

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals