EST-AH Door Type Single Rack Low Temperature Straight Dishwasher
Product Information
The product is available in two models: EST-AH and EST-C. The
product comes with a delimer switch, on/off power switch, detergent
switch, drain switch, rinse switch, and a sani switch. It has a 1
1/2 water inlet and a 2 drain outlet. The product has a peristaltic
pump and a CMA energy saver. It also has a poly proTM scrap
accumulator and 4 leveling legs. The product is shipped without a
thermometer installed, but a thermometer is included in the
dishwasher, zip-tied to the dishrack. The dishwasher requires a
hard wire power supply and compliance with all Federal, State, and
Local Health, Electrical, Plumbing, and Safety codes.
Product Usage Instructions
- Connect the dishmachine to a hot water source recommended at
140 degrees Fahrenheit (minimum temperature required is 120 degrees
Fahrenheit). - Connect a 2 drain pipe (not supplied) from the scrap
accumulator to the floor or wall drain. - Insert tube stiffener with chemical tubing into each
corresponding chemical dispensers. - Level the dishmachine by adjusting the leveling legs. The
dishmachine must be level front and back to ensure proper
performance. - Press the FILL/START switch and hold it in the FILL position
until the water overflows into the scrap accumulator. - Open the dishmachine doors completely. Closing the doors will
automatically activate the machine.
Note: All electrical and plumbing connections should be made by
a licensed service person and comply with all Federal, State, and
Local Health, Electrical, Plumbing, and Safety codes. The
thermometer needs to be installed using Teflon tape to prevent
leaking.
Models EST-AH , EST-C EST-AH-(EXT) & EST-C-(EXT) Quick Setup Instructions
WARNING: Electrical and plumbing connections need to be made by a licensed service person and comply with all Federal, State and Local Health, Electrical, Plumbing and Safety codes.
NORMAL-OFF DELIMER SWITCH
ON/OFF POWER SWITCH
1 1/2″ WATER INLET
MODEL EST REAR VIEW
HARD WIRE POWER SUPPLY
3 TUBE STIFFENER
3 CHEMICAL TUBING
STEP
1
2 2″ DRAIN OUTLET
STEP
2
STEP
3 RED
WHITE
BLUE
Connect dishmachine to hot water source recommended 140 temperature (120 minimum temperature required).
PN: 10130.13
8″
WALL DRAIN
FLOOR DRAIN
Connect a 2″ drain pipe (not supplied) from scrap accumulator to floor or wall drain.
Insert tube stiffener with chemical tubing into each corresponding chemical dispensers.
07-2021
Models EST-AH
EST-C, EST-AH-(EXT) & EST-C-(EXT)
Quick Setup
Instructions
DETERGENT SWITCH
WARNING: Electrical and plumbing connections need to be made by alicensed service person and comply with allFederal, State and Local Health, Electrical, Plumbing and Safety codes.
PERISTALTIC PUMP
THERMOMETER NEEDS TO
BE INSTALLED:
The Models EST-AH and EST-C are Shipped from CMA without thermometer being installed. To prevent leaking, the installation Team will need to install it on the dishwasher using TEFLON TAPE. So the thermometer for this unit is not misplaced during shipment, please find thermometer shipped inside the dishwasher, zip-tied to the dishrack.
MODEL EST FRONT VIEW
CMA ENERGY SAVER
000000
POLY PROTM SCRAP ACCUMULATOR
STEP
4
STEP
5 CMA ENERGY SAVER
000000
STEP
6
SANI SWITCH
DRAIN SWITCH
RINSE SWITCH
5 FILL/START SWITCH
CYCLE LIGHT
DOOR HANDLE
6
4 LEVELING LEGS
000000
Level dishmachine by adjusting leveling legs. Dishmachine must be level front and back to ensure proper performance.
Press the “FILL/START” switch. Hold in the “FILL” position until the water overflows into the scrap accumulator.
an Ali Group Company
Open dishmachine doors completely. Closing the doors will automatically activate the machine.
07-2021
The Spirit of Excellence