Minka Lavery 2663-723 Colonial Charm 3 Light Old World Bronze Candlestick Chandelier Instruction Manual

2663-723 Colonial Charm 3 Light Old World Bronze Candlestick Chandelier

Product Information

The product is identified as item#2663-723, and the user manual
is dated 04/02/2022. The product is a fixture that requires
installation and can be used with candelabra base bulbs up to 60
watts each or CFL or LED equivalent bulbs. The fixture comes with
wooden drops, bobeches, candle covers, a ground screw, two mounting
screws, and a crossbar. The fixture has adjustable arms and a loop
for coupling. The fixture also includes a chain that needs to be
opened and closed using proper chain pliers, which are not included
in the package.

Product Usage Instructions

  1. Shut off the power at the fuse box or circuit breaker before
    starting the installation process.
  2. If necessary, remove the old fixture, including mounting
    hardware.
  3. Take the new fixture out of the carton and check that all parts
    are included as shown in the illustration.
  4. Adjust the arms (I) to the proper position as shown in the
    illustration (L).
  5. Screw the fixture loop (A) to coupling (B).
  6. Thread all thread into the ceiling loop until snug.
  7. Thread the other end of the all thread into the crossbar.
  8. Connect the electrical wires as shown in Fig. 3 making sure
    that all wire connectors are secured.
  9. If your outlet box has a ground wire (green or bare copper),
    connect the fixture’s ground wire to it. Otherwise, connect the
    fixture’s ground wire directly to the crossbar using the green
    screw provided.
  10. Tuck wire connections neatly into the outlet box.
  11. Raise canopy to ceiling and secure with lock collar.
  12. Place bobeches (K) over candle covers (J).
  13. Hang wooden drops (D, M, N, O) onto fixture body in the proper
    position.
  14. Thread finial (H) to fixture body and attach wooden drop
    (O).
  15. Install (3) three candelabra base bulbs up to 60 watts each, or
    CFL or LED equivalent bulbs (not included), in accordance with the
    fixture specification–DO NOT EXCEED THE MAXIMUM WATTAGE RATING!
    (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).
  16. Return power to the outlet box and test the fixture.

Note: The illustration (Fig. 1) in the manual is for
installation purposes only and may or may not be identical to the
fixture purchased. It is important to use proper chain pliers to
open and close the chain included with this fixture. Do not open
them with other tools that may twist or stress the chain links.

INSTALLATION INSTRUCTIONS
Item#2663-723 (New. 04/02/2022) READ AND SAVE THESE INSTRUCTIONS
W ARNI N G ! S HU T PO WE R O F F AT F US E OR CI RC UI T BR E AK E R.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

ASSEMBLING THE FIXTURE (Fig. 1) 1. Shut off the power at the fuse box or circuit breaker. If
necessary, remove old fixture, including mounting hardware. 2. Carefully remove fixture from carton and check that all parts are
included as shown in the illustration. 3. Adjust the arms (I) to proper position. Refer to illustration (L).
4. Screw fixture loop (A) to coupling (B).
MOUNTING THE FIXTURE (Fig. 2) 5. Thread all thread into ceiling loop until snug. 6. Thread the other end of the all thread into crossbar. Note: The
length of the all thread into crossbar may be adjusted if necessary. 7. Secure all thread to crossbar with hex nut. 8. Take crossbar assembly and mount it to outlet box using the mounting screws (Size: #8-32N*L1″). The side of crossbar marked “GND” must face out. 9. Open quick link and connect to fixture loop, then close quick link. 10. By measuring, determine the correct number of links needed for desired hanging height. Using chain pliers, disconnect and discard excess chain. 11. Carefully lace fixture wires through chain. 12. Slip lock collar and canopy over chain and allow them to rest on fixture body. 13. Open the quick link and attach it to the ceiling loop, then close quick link. 14. Carefully feed fixture wires through ceiling loop and all thread and pull until tight.
CONNECTING THE WIRES (Fig. 3) 15. Connect the electrical wires as shown in Fig. 3 making sure that
all wire connectors are secured. If your outlet box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the crossbar using the green screw provided. 16. Tuck wire connections neatly into outlet box. Raise canopy to ceiling and secure with lock collar.
FINISHING THE INSTALLATION (Fig.1) 17. Place bobeches (K) over candle covers (J). 18. Hang wooden drops (D,M,N,O) onto fixture body in proper
position. 19. Thread finial (H) to fixture body and attach wooden drop (O).
20. Install (3) three candelabra base bulbs up to 60 watts each or
CFL or LED equivalent (not included) in accordance with the
fixture specification–DO NOT EXCEED THE MAXIMUM
WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE
NOMINALE MAXIMALE!).

Fig. 1

Code D M N O

Wooden Drop# WD2669-P1 WD2663-P1 WD2663-P2 WD2663-P3

Set# A-010 -Crossbar -Ground screw -Mounting Screw *2 Candle Cover # CCV21080P-737
Fig. 2

Chain # HCH1072-737

Your installation is now complete. Return power to the outlet box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.

Fig. 3
FIXTURE WIRES Black or Smooth

FIXTURE WIRES White or Ribbed HOUSE WIRES Black (Hot)

FIXTURE WIRES Bare Copper (Ground) HOUSE WIRES White (Neutral)

QTY/Item 3 3 6 4
HOUSE WIRES Green (Ground)

Notice: It is important to use proper chain pliers (not included) To OPEN and CLOSE the chain included with this fixture. Do not open them with other tools that may twist or stress the chain links. It is important to use proper chain pliers like the ones shown in the diagram.
LA-3499E

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals