Sargent 1130 Series Non Handed Door Closer Instruction Manual

1130 Series Non Handed Door Closer

Product Information: 1130 Series Non-Handed Door Closer Arm
Model 1131

The 1130 Series Non-Handed Door Closer Arm Model 1131 is a
non-hold open arm model that comes with adjustable size 1-6. The
product is available in four types of installation – Regular Arm,
Top Jamb Mount, Parallel Arm, and Right Hand Door – RH Left Hand
Reverse – LHR. The product comes with a warning that it contains
lead which is known to the state of California to cause cancer and
birth defects or other reproductive harm. The product includes a
closer, pinion cap, 1/8 hex wrench, and screw pack. The product
also has optional components such as Main Arm Pinion Screw Regular
Arm/ Top Jamb Shoe, Arm Assembly, Main Arm, RU Soffit Plate (Used
with Parallel Arm Installation Only), Connecting Rod Forearm Screw,
Arm Slide, 60-0535 Cover, and 6-32 x 5/16 Pan Head Self Tapping
Screw. The product can be used for both exterior and interior
doors.

Product Usage Instructions: 1130 Series Non-Handed Door Closer
Arm Model 1131

Before starting the installation process, it is important to
determine the hand of the door and identify your model. For
determining the hand of the door, follow these instructions:

  • Right Hand Reverse – LEFT HAND DOOR
  • Left Hand Reverse – RIGHT HAND DOOR

To identify your model, refer to the product information section
of the user manual.

Follow these instructions for the installation process:

  • Read and follow all instructions given in the user manual. Save
    the instructions for future reference.
  • An incorrectly installed or improperly adjusted door closer can
    cause property damage or personal injury. Follow the installation
    instructions carefully to avoid the possibility of misapplication
    or misadjustment.
  • Doors should be hung on ball bearing or anti-friction hinges. A
    separate door stop is recommended.
  • Use the provided hardware for mounting the product.
  • Drill holes in the door or frame as per the given dimensions in
    inches (millimeters).

The product comes with closer adjustments that can be made using
the provided hex wrench. Never force valves out of the closer and
never completely close backcheck valve. Door must be open to adjust
spring closing power. Refer to the chart given in the user manual
for making adjustments.

Note: The use of a power drill will void the Warranty.

The product can be used for both exterior and interior doors.
Refer to the table given in the user manual for maximum door size
and type of installation.

1130 Series Non-Handed Door Closer Arm Model 1131 Installation Instructions
Non-hold Open arm model, adjustable size 1-6 ( )
WARNING
This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm. For more information go to: www.P65warnings.ca.gov.

READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

Regular Arm

Top Jamb Mount

Parallel Arm

Right Hand Door – RH Left Hand Reverse – LHR

Right Hand Door – RH Left Hand Reverse – LHR

Right Hand Door – RH Left Hand Reverse – LHR

Left Hand Door – LH Right Hand Reverse – RHR

Left Hand Door – LH Right Hand Reverse – RHR

Left Hand Door – LH Right Hand Reverse – RHR

Included Components Closer
Pinion Cap 1/8″ Hex Wrench
Screw Pack
(Refer to page 2 for a list of contents)

Optional Components

Main Arm Pinion Screw Regular Arm/ Top Jamb Shoe

Arm Assembly
Main Arm

RU Soffit Plate (Used with Parallel Arm Installation Only)

Connecting Rod Forearm Screw

Arm Slide

60-0535 Cover

6-32 x 5/16″ Pan Head Self Tapping Screw

To Determine Your Hand of Door:

Right Hand Reverse
LEFT HAND DOOR

Left Hand Reverse
RIGHT HAND DOOR

To Identify Your Model:
Spring Power Adjustment

Tools Needed:

Size Code

BC Valve

Date Code

Copyright © 2016, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
A7674D 80-9311-0011-021 Rev 4 02/23 Approved 2023-02-24

1130 Series Non Hold Open Closer

ATTENTION:
An incorrectly installed or improperly adjusted door closer can cause property damage or personal injury. These installation instructions should be followed to avoid the possibility of misapplication or misadjustment.
y For special applications, a separate door and frame preparation template is packed with these instructions. Use this instruction sheet for installation sequence and closer adjustments only.
y Doors should be hung on ball bearing or anti-friction hinges.
y A separate door stop is recommended.
Supplied Hardware
Mounting Hardware
Closer, PA Bracket: 1/4-14 x 1-1/2 Oval Flat Head Self Drilling Screw
Closer, PA Bracket: 1/4-20 x 3/4 Oval Flat Head Mach. Screw
Arm Shoe to Jamb or Door: 1/4-20 x 5/8 Round Head Mach. Screw
Arm Shoe to Jamb or Door: 1/4-14 x 1-1/2 Round Head Self Drilling Screw
Closer: Sleeve Nut and Bolt (SNB) (optional) with 1/4-20 x 3/4 Oval Flat Head Mach. Screw
(recommended)
Closer: Thru Bolt and Grommet Nut (TBGN) (optional)

y Always consult door/frame manufacturer for fastener compatibility. y Door and frame must be properly reinforced. y Adjust closing time speed between 3 and 7 seconds from 90° to 0°. y These door closers should NOT be installed on exposed side
(weather side) of exterior doors. y Dimensions are given in inches (millimeters).

Door or Frame Wood/Metal

Drill 3/16″ (4.8mm) for wood

Metal

Drill #7 (.201 dia. or 5.1mm) Tap 1/4-20

Wood/Metal Hollow Metal Aluminum or Wood
All

3/16″ (4.8mm) for wood
9/32″ (7.0mm) thru 3/8″ (9.5mm) door face opposite to closer
3/8″ (9.5mm) thru
9/32″ (7.0mm) thru 3/8″ (9.5mm) dia. x 3/8″ (9.5mm) deep, door face opposite to closer

Closer Adjustments

Use provided hex wrench to turn valves. NEVER force valves out of closer. NEVER completely close backcheck valve. Door must be open to adjust spring closing power. Refer to the chart.

Use of a power drill will void the Warranty.

Spring Closing Power

Number of Turns Required

Latch Slower

Sweep Slower

Faster

Faster

Backcheck Stronger
Weaker

1131 Exterior Interior Door
Full 360° Turns

Type of Installation

Maximum Door Size

* 34″

36″

40″

44″

48″

(0.85M) (0.90M) (1.00M) (1.10M) (1.20M)

Regular Arm Top Jamb

2

4

6

10

12

Parallel Arm

3

5

8

11

14

Regular Arm Top Jamb

3

5

8

11

14

Parallel Arm

5

8

11

16

19

*30 Full (360°) turns maximum available = turns as shipped

Pinion Cap or Cover
or Do not over tighten cap or cover screws.

or

or

Regular Arm

Top Jamb Mount

Parallel Arm

Copyright © 2016, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part without the

express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.

2 Approved 2023-02-24

A7674D 80-9311-0011-021 Rev 4 02/23

1130 Series Non Hold Open Closer

1130 Regular Arm Installation (Right Hand Shown)
1. Prepare door and frame.

A
1-1/4 (32)

6 (152)

1-3/4 (44)

3

7/8 (22)

3/4

(19)

9-1/16

(230)

Opening

Dimension “A”

to 100°

7 (178)

101° to 120°

6 (152)

*121° to 180°

3-1/2 (89)

*Door/Wall/Hardware/Jamb conditions permitting

2. Mount closer to door.
or
x4

3. Choose arm placement in shoe and install arms.

1st

2nd

RH and LH:

Position flat at S

7-1/2% Stronger +

­

or

7-1/2%

Weaker

x2

4. Connect arms and install forearm screw.

5. Preload spring and tighten forearm screw.

1st 2nd

Rotate elbow until

1st

Connecting Rod is

perpendicular to frame.

Rotating arm preloads closer spring power.
2nd

The 1130 Non Hold Open Closer – Regular Arm has now been installed.
Go to page 2 for closer adjustments and decorative cap or cover installation.

Copyright © 2016, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole

or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.

A7674D 80-9311-0011-021 Rev 4 02/23 Approved 2023-02-24

3

S Z
A

1130 Series Non Hold Open Closer

1130 Top Jamb Arm Installation (Right Hand Shown)
1. Prepare door and frame.

9-1/16 (230)

1-1/2 (38)
1-3/4 (44)

6 (152)

3/4 (19)
1/2 (13)

Top of Door
CL

Opening

Dimension “A”

to 100°

7-1/2 (191)

101° to 120°

6 (152)

*121° to 180°

3-1/2 (89)

*Door/Wall/Hardware/Jamb conditions permitting

A longer connecting rod is required for reveals
greater than 3″ (76mm)

Reveal

2. Mount closer to frame.

3. Choose arm placement in shoe and install separate arms.

or
x4
4. Connect arms and install forearm screw.

­ 7-1/2% Weaker
or
or + 7-1/2% Stronger

or
x2
L
RH and LH: Position flat at S

R

Y

5. Preload spring and tighten forearm screw.

Rotating arm preloads closer spring power.

1st 2nd

2nd

1st
Rotate elbow until Connecting Rod is perpendicular to frame.

The 1130 Non Hold Open Closer – Top Jamb Mount has now been installed. Go to page 2 for closer adjustments and decorative cap or cover installation.

Copyright © 2016, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part without the

express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.

4 Approved 2023-02-24

A7674D 80-9311-0011-021 Rev 4 02/23

1130 Series Non Hold Open Closer

1130 Parallel Arm Installation (Right Hand Shown)

1. Prepare door and frame.

A

2-3/4

(70)

3/8

(10)

2 (50)

7/16

1/2

(11)

(13)

Door Opening

Dimension Dimension

“A”

“B”

to 100°

9-1/4 (235)

7-5/8 (194)

101° to 130° 7-3/4 (197)

6-1/8 (156)

*131° to 180° 5-3/4 (146)

4-1/8 (105)

*Door/Wall/Hardware/Jamb conditions permitting

Top of Door
9-1/16 (230)

B
Frame 3-1/4 (83)
3/4 (19)
CL

2. Close latch and sweep valves.
IMPORTANT

3. Install soffit plate and mount closer.
or
x4
or
x4

4. Remove arm shoe and install forearm to plate.
2nd 1st

5. Place main arm on closer spindle and rotate

Copyright © 2016, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole

or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.

A7674D 80-9311-0011-021 Rev 4 02/23 Approved 2023-02-24

5

1130 Parallel Arm Installation (Right Hand Shown) cont.

6. Remove arm and attach as shown.

7. Open latch and sweep valves.

Right Hand Door
or Left Hand Door
Flat

1st Flat

2nd

RH: Position flat at R LH: Position flat at L

8. Connect arms and install forearm screw.
1st

3rd 2nd

Do not completely open valves. Valves
will leak. Arm under tension. Keep fingers away from moving parts.

9. Preload spring and tighten forearm screw.

1-1/2 (38)
2nd
By hand, rotate arm elbow to be 1-1/2″ from
door face.

1st 3rd

Rotating arm preloads closer spring power.

The 1130 Non Hold Open Closer – Parallel Arm Mount has now been installed. Go to page 2 for closer adjustments and decorative cap or cover installation.

WARNING
This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov.
1-800-727-5477 · www.sargentlock.com Copyright © 2016, 2023, SARGENT Manufacturing Company. All rights reserved. Reproduction in whole or in part without the express written permission
Approved 2023-02-24 of SARGENT Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents.

WARNING
Attention Installer: Improper installation may result in damage to the product and void the factory warranty.
A7674D 80-9311-0011-021 Rev 4 02/23

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals