Unpack Generator: Remove generator, accessories, inserts and Literature from carton. If any item is missing or damaged, contact our product service department
at 855-888-3598.

Included ItemsA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-1

Manual

WARNING

This Quick Reference Guide is not substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and underdstand the operator’s manual before using this product. All pages references to the operator’s manual.

Add Lubricant and Fuel

  • Remove maintenance cover and use a funnel to pour 10W-30 engine oil into engine. Fill to the upper mark of the oil dipstick H.A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-2
  • Use clean/fresh regular UNLEADED gasoline with a minimum 87 octane.
  • Use Propane/LPG hose with regulator to connect propane/LPG tank and generator.

Start Generator

Move generator outside to a flat, level surface, away from doors, windows and vents.

Danger

Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-3

  • NEVER use inside a home or garage, EVEN IF doors and windows are open.
  • Only use OUTSIDE and far away from windows, doors and vents.A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-4
  • Avoid other generator hazards. READ THE MANUAL BEFORE USE.
  • WARNING Do not overload generator or electrical cords. Consult operation manual.
  • Select the Fuel Source (Gasoline)A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-5
  • Add gasoline to the fuel tank
  • Make certain the propane tank is fully closed
  • Turn the starting dial switch to the START position.A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-7A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-6
  • Pull the recoil starter slowly until resistance is felt, then pull rapidly.
  • Turn the starting dial switch to the RUN A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-9positionA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-8
  • Note: For restarting a warm engine, turn the starting dial switch directly to the “RUN” A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-9 position.
  • Select the Fuel Source (Propane/LPG) A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-10
  • Connect the LPG gas hose to the propane fuel source.
  • Fully open the Propane/LPG cylinder knob.
  • Turn the starting dial switch to the START position.A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-7A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-11
  • Pull recoil starter twice
  • Turn the starting dial switch to the RUNA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-9 position.
  • Pull recoil starter slowly until resistance is felt, then pull rapidlyA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-12

Shutdown and StorageA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-13

  • Remove any load from the generator
  • Turn the starting dial switch to the OFFA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-14position.
  • Turn the fuel valve knob to the OFF positionA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-15
  • If a generator is to be stored for longer than 30 days, refer to the operator’s manual for further Instruction

Changing Fuels

  • Disconnect all electrical loads from the generatorA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-16
  • Gasoline to propane/LPGA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-17
  • Propane/LPG to GasolineA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-18
  • Connect the LPG gas hose to the propane fuel sourceA-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-19
  • Fully open the Propane/LPG cylinder knob.
  • Make certain the propane tank is fully closed.A-iPOWER-GXS4300iDC-Dual-Fuel-Inverter-Generator-FIG-20
  • Questions? Call 855-888-3598 or email [email protected] Tiene preguntas? Llame al 855-888-3598 o escriba a [email protected]
  • Des questions? Téléphoner au 855-888-3598 ou envoyer un courriel à [email protected]