20351-05 2 Light Bathroom Mate
Product Information: NEWTON Bathroom Heaters
The NEWTON Bathroom Heaters are designed to provide instant heat
to persons standing directly underneath them. The package includes
a bathroom heater, a 9W R63 LED Globe Cool White, 275W heat lamps,
an exterior vent, and a switch plate. This product is designed for
installation in flat ceilings only and should not be mounted on a
sloping ceiling or vertical wall. The heater lamps are not meant
for extended periods of operation.
Product Usage Instructions
- Read all instructions before commencing installation, even if
you are familiar with this type of product. - Ensure that the fitting is installed by a qualified electrical
contractor in accordance with the latest edition of AS/NZS
3000. - Operate the product from a power source of the same voltage,
frequency, and rating as indicated on the rating label. - Install the unit above an area where “drying off” usually
occurs for effective heat distribution. - Do not install the product in a location where there is a
possibility of water splashing onto the lamps. - Locate and install the product in accordance with the
requirements of AS/NZS 3000 and local building codes. - Ensure adequate ventilation by allowing replacement air to
enter the room equivalent to what is being extracted by the exhaust
fan. - If the room is airtight, ensure that there is airflow under the
door or through a slightly open window. - Ensure that there is enough space within the roof cavity for
steam dissipation. - If the roof cavity is restricted or not well ventilated, it is
recommended to use duct and vent to extract steam to an outside
area. - Mount the unit at least 250mm away from vertical walls.
- Provide a minimum clearance of 100mm above the top of the
unit. - Ensure a minimum of 50mm clearance between the sides of the
unit and joists, walls, or insulation. - Follow the provided electrical wiring diagram for proper
installation. - Fix and tighten the clamps firmly to hold the flexible duct to
the unit and the outer wall vent during installation. - Ensure that the flexible duct does not obstruct or block the
anti-draft stopper, as it would reduce overall airflow.
NEWTON Bathroom Heaters
20351/05 2 Heat Lamps 20352/05 4 Heat Lamps
Please read all instructions before commencing installation even if you are familiar with this type of product.
THIS FITTING MUST BE INSTALLED BY A QUALIFIED ELECTRICAL CONTRACTOR in accordance with the latest edition of AS/NZS 3000
Parts List
1. Bathroom Heater
2. 9W R63 LED Globe Cool White
3. 275W Heat Lamps
4. Ø100mm Duct 1.5m Length
5. Exterior Vent
6. Switch Plate
For your Safety
· To prevent electrical shock, please ensure that power is DISCONNECTED before installing.
· Be aware of the height of your installation. Refer to `Working at Heights ” guide from your local or State
Authorities.
· This product must be used only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to persons. If you have questions, contact the supplier
or local agent.
· All wiring must be carried out by a licensed electrician in accordance with all applicable national / local codes
and standards. Also check with the local council regulations regarding installation of exhaust fans.
· When cutting into the ceiling material, care must be taken to ensure you do not damage the existing ceiling
structure, existing electrical wiring and other hidden utilities.
· This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
· Children should be supervised to ensure that they do not play with the unit.
· The lamps are extremely hot when in use. Allow all lamps to cool sufficiently before touching or replacement.
· For the purpose of avoiding any fumes leaking into your bathroom, the duct for the heater must not be laid
together with ducts for air-fuelled water heaters or other open-fire appliances.
· Any alterations or additions to building wiring must be completed by a licensed electrician or person
1
authorised by legislation to work on the fixed wiring of any electrical installation
NEWTON Bathroom Heaters
20351/05 2 Heat Lamps 20352/05 4 Heat Lamps
Introduction and Considerations
Read these instructions carefully before installing & using the product.
Always operate this product from a power source of the same voltage, frequency and rating as indicated on rating label.
The Infra-Red lamps are not designed to heat the entire room area, they provide instant heat to persons standing directly underneath them. Install the unit above an area where `drying off’ usually occurs.
This product is designed for installation in flat ceilings only. Don’t mount on a sloping ceiling or a vertical wall.
Heater lamps are not designed for extended periods of operation.
Locate and install the product in accordance with the requirements of AS/NZS 3000 and local building codes. Do not install in a location where there is a possibility of water splashing onto the lamps.
Ventilation Requirements
For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room.
Generally, air would be drawn under the door, or through a slightly open window. If the room is airtight, the fan will operate poorly. Air flow path should ideally pass over the steam source.
It is also essential the there is adequate space within the roof cavity so the steam can dissipate.
If roof cavity is restricted or not well ventilated it is recommended that duct and vent be used to extract steam to an outside area.
Door Airflow
Window
280mm
100mm
Joist
250mm
50mm
Clearance Requirements
This unit must be mounted at least 250mm away from vertical walls.
A minimum clearance of 100mm is required above the top of the unit.
Additionally a minimum of 50mm clearance is required between the sides of unit and joists, walls or insulation.
2
Wall
NEWTON Bathroom Heaters
20351/05 2 Heat Lamps 20352/05 4 Heat Lamps
Installation
1) This unit must be mounted at least 2 metres above the floor and at least 250mm away from vertical walls. 2) Remove the heat globes from the unit to prevent breakages. 3) Remove the grille by releasing 4 springs in each corner of the unit. 4) Ensure area behind the installation location is clear of all cables, pipes, joists or hidden utilities. 5) Use the template provided to mark and cut a hole in the ceiling (Refer specifications for hole size). 6) Remove rear terminal cover and connect wires as per wiring diagram on page 3. Refit terminal cover. 7) Push the unit into the ceiling hole ensuring inbuilt clip fasteners hold unit securely in place. 8) Additional screws can be applied around the metal flange plate to hold the unit to the ceiling. 9) Secure grille with springs and insert lamps. 10) Attach ducting if required to extract the air to the outer wall using 1.5 long flexible ducting, clamps and vent
outlet grille provided. Fix and tighten the clamps firmly to hold the flexible duct to the unit and the outer wall vent. 11) Ensure that the flexible duct, when connected to the unit doesn’t obstruct or block the anti-draft stopper, as it would reduce the overall airflow.
Electrical wiring diagram
* * Second heat switch not required for model with 2 heat lamps
Operation
The unit requires `permanent active’. The fitting is fitted with a thermal cut-out which will turn the motor (FAN) `ON’ when them internal temperature exceeds 80°C.
1) Double pole disconnecting device must be fitted in the circuit. 2) Ensure the power is switched “OFF” at the mains before
commencing installation. 3) Remove the cover on the back of the enclosure to access the
terminals. 4) Connect wires as per electrical wiring diagram and markings
adjacent to terminal block. 5) Replace the cover removed earlier.
This unit uses Infrared heating lamps as a heat source. It also has an exhaust fan and an LED light.
· Heating: Switch the `Heat’ button `ON’ on the wall switch. The heat globes provide instantaneous heat from the moment they are switched `ON’.
· Exhaust Fan: Use the switch button `Fan’ to turn it ON and Off. · LED Light: Operate the LED light independently from heat globes, using `Light’ On /Off switch button.
Cleaning
· Switch off the power before commencing cleaning and wait until the globes cool down. · Regularly wipe globes and front fascia with soft cloth soaked with water or neutral detergent if required. · Clean the exhaust fan from dust and dirt with dry or wet cloth if required. · Clean the exhaust ducting kit and ensure airways are clean and there are no obstructions at the exit
from the wall.
Replacement Lamps
· Heat Lamps Hard Glass, Infrared, R125, 240V, 275W
· Light Lamp R63, 240V, 9W Max
3
NEWTON Bathroom Heaters
20351/05 2 Heat Lamps 20352/05 4 Heat Lamps
Specifications
Model No Fascia colour Rating Heat Lamps LED Lamp Airflow Cut out hole size
Dimensions Noise IP rating Weight
20351/05 (2 Heat Lamps), 20352/05 (4 Heat Lamps)
/05 – White
240V, 50Hz, 594W (20351/05), 1144W (20352/05) 240VAC, R125, E27, 275W 9W, 860lm, Cool White, Non dimmable 240m3/h (at exit point from the unit)
345mm x 185mm (20351/05), 295mm x 295mm (20352/05) 20351/05 – 400mm L x 225mm W x (180mm H excluding grille) 20352/05 – 362mm L x 362mm W x (175mm H excluding grille) <45dB IPX2 3.0kg (20351/05), 3.6kg (20352/05)
Warranty:
Brilliant Lighting warrants this product against defects in manufacture and workmanship for a period of 3 years from date of purchase.. This warranty is only valid for products installed by a qualified electrical contractor and operated within the guidelines specified by Brilliant Lighting, and within the correct operating voltage ranges as stated on the product’s rating label.
Warranty does not include damage or loss arising from incorrect installation, operation or maintenance of this product, damage caused through modification, incorrect installation, service by unqualified or unauthorised personnel or lack of regular maintenance and cleaning. Proof of installation by qualified personnel may be required, e.g.. Electrical Safety Certificate. Proof of purchase must be supplied with all warranty claims.
This warranty is provided in addition to any other rights and remedies of the customer under any law. In applications not intended for household, personal or domestic use, liability is limited to replacement or reimbursement of product only.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure.
Any claim under this warranty must be made within the specified warranty period from date of purchase of this
product. To make a claim under the warranty, take the product (with proof of purchase receipt or similar) to the store where you purchased the product or contact Brilliant Lighting at the address below.
This warranty is given by:
Brilliant Lighting (Aust) Pty. Ltd.
ABN 37 006 203 694
956 Stud Road Rowville, VIC 3178
Phone: 03 9765 2555
Email: [email protected]
Made in China
4