N7524-716-L 165 Watt Equivalence Integrated LED Smoked Iron Pendant

Product Information: Convertible Lamps for Pendant and Semi
Flush Mount

The Item#N7524-716-L Convertible Lamps are designed for pendant
and semi-flush mount installations. The product comes with a
mounting plate, ground screw, and mounting screws for easy
installation. The fixture wires are black or smooth, white or
ribbed, and bare copper for ground connection. The product is
dimmable with ELV and/or LED compatible wall dimmer switches.

Product Usage Instructions: Pendant Installation

  1. Shut off power at the fuse box or circuit breaker box and
    remove the old fixture including the mounting hardware.
  2. Carefully unpack your new fixture and lay out all the parts on
    a clean area. Take care not to misplace any small parts necessary
    for installation.
  3. Loosen screws (K) to remove mounting plate (A) from canopy
    (L).
  4. Determine desired hanging height and thread rods (F1, F2 and
    F3) to all thread (I) on top of fixture body. Carefully pass wires
    through each rod during assembly. Secure swivels (G) onto rods
    (F1).
  5. Align canopy (L) and metal plate (H) followed by lock washer
    (E) and metal washer (D) onto swivels (G) and secure with hex nuts
    (C) via wrench (J) (Not included).
  6. Attach mounting plate (A) to junction box (Not included) with
    mounting screws (B) (Size: #8-32N*L0.5). The side of mounting plate
    (A) marked GND and two convex points must face out.
  7. Connect the electrical wires as shown in Fig. 2, making sure
    that all wire connectors are secured. If your junction box has a
    ground wire (green or bare copper), connect fixture’s ground wire
    to it. Otherwise, connect fixture’s ground wire directly to
    mounting plate (A) using green screw provided.
  8. Tuck wire connections neatly into junction box.
  9. Place canopy (L) over mounting plate (A) and secure with screws
    (K).
  10. Turn on power to the junction box and test the fixture.

Product Usage Instructions: Semi Flush Mount Installation

  1. Loosen screws (K) to remove mounting plate (A) from canopy
    (L).
  2. Secure rod (M) into all thread (I).
  3. Thread canopy (L), metal plate (H), lock washer (E), metal
    washer (D) and hex nut (C) into all thread on top of rod (M). Then
    secure hex nut (C) by using wrench (J) (Not included).
  4. Attach mounting plate (A) to junction box (Not included) with
    mounting screws (B) (Size: #8-32N*L0.5). The side of mounting plate
    (A) marked GND and two convex points must face out.
  5. Connect the electrical wires as shown in Fig. 2, making sure
    that all wire connectors are secured. If your junction box has a
    ground wire (green or bare copper), connect fixture’s ground wire
    to it. Otherwise, connect fixture’s ground wire directly to
    mounting plate (A) using green screw provided.
  6. Tuck wire connections neatly into junction box.
  7. Place canopy (L) over mounting plate (A) and secure with screws
    (K).
  8. Turn on power to the junction box and test the fixture.

INSTALLATION INSTRUCTIONS

Item#N7524-716-L (Convertible Lamps for Pendant) (New. 2022/05/19) READ AND SAVE THESE INSTRUCTIONS
W AR NI N G ! S HU T P O WE R O F F AT F U S E O R CI R C UI T B R E AK E R .

AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

MOUNTING THE FIXTURE (Fig.1)

Fig. 1

1. Shut off power at the fuse box or circuit breaker box and Set# A-021-172D

remove the old fixture including the mounting hardware. 2. Carefully unpack your new fixture and lay out all the parts

-Mounting plate -Ground screw -Mounting screws *2

on a clean area. Take care not to misplace any small parts

necessary for installation.

A

3. Loosen screws (K) to remove mounting plate (A) from

B

canopy (L).

C

J

4. Determine desired hanging height and thread rods (F1, F2

D

and F3) to all thread (I) on top of fixture body. Carefully

E

K

pass wires through each rod during assembly. Secure

H

L

swivels (G) onto rods (F1).

5. Align canopy (L) and metal plate (H) followed by lock washer (E) and metal washer (D) onto swivels (G) and

G

secure with hex nuts (C) via wrench (J) (Not included). 6. Attach mounting plate (A) to junction box (Not included)
with mounting screws (B) (Size: #8-32N*L0.5″). The side of mounting plate (A) marked “GND” and two convex points

F1
Rod# W30-1-172 *2 (F1) W30-1-172 *4 (F2) W30-H-172 *2 (F3)

must face out.

CONNECTING THE WIRES (Fig. 2)

7. Connect the electrical wires as shown in Fig. 2, making

F2

sure that all wire connectors are secured. If your junction

box has a ground wire (green or bare copper), connect

fixture’s ground wire to it. Otherwise, connect fixture’s

F3

ground wire directly to mounting plate (A) using green

I

screw provided.

8. Tuck wire connections neatly into junction box.

FINISHING THE INSTALLATION (Fig.1)

9. Place canopy (L) over mounting plate (A) and secure with

screws (K).

Your installation is now complete. Return power to the

junction box and test the fixture.

Fig. 2

Note: Illustration (Fig.1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.

FIXTURE WIRES Black or Smooth

Dimmable with ELV and/or LED compatible wall dimmer switches.

FIXTURE WIRES White or Ribbed HOUSE WIRES Black (Hot)

FIXTURE WIRES Bare Copper (Ground) HOUSE WIRES White (Neutral)

HOUSE WIRES Green (Ground)

Page:1/2

LA-3550E

INSTALLATION INSTRUCTIONS

Item# N7524-716-L (Convertible Lamps for Semi Flush Mount) (New. 2022/05/19) READ AND SAVE THESE INSTRUCTIONS
W AR NI N G ! S HU T P O WE R O F F AT F U S E O R CI R C UI T B R E AK E R .

AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEU

PREPARATION (Fig.3)

1. Loosen screws (K) to remove mounting plate (A) from Fig. 3

canopy (L). 2. Secure rod (M) into all thread (I). 3. Thread canopy (L), metal plate (H), lock washer (E), metal

Set# A-021-172D -Mounting plate -Ground screw -Mounting screws*2

washer (D) and hex nut (C) into all thread on top of rod (M).

Then secure hex nut (C) by using wrench (J) (Not included). (Fig. 3)

A

4. Attach mounting plate (A) to junction box (Not included)

B

with mounting screws (B) (Size: #8-32N*L0.5″). The side of

C

J

mounting plate (A) marked “GND” and two convex points

D

must face out.

E

K

CONNECTING THE WIRES (Fig. 2)

H

5. Connect the electrical wires as shown in Fig. 2, making

L

sure that all wire connectors are secured. If your junction

box has a ground wire (green or bare copper), connect

fixture’s ground wire to it. Otherwise, connect fixture’s

ground wire directly to mounting plate (A) using green

M

screw provided.

6. Tuck the wire connections neatly into junction box.

I

FINISHING THE INSTALLATION (Fig.3)

7. Place canopy (L) over mounting plate (A) and secure with

screws (K).

Your installation is now complete. Return power to the junction box and test the fixture.
Note: Illustration (Fig.3) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.
Dimmable with ELV and/or LED compatible wall dimmer switches.