2311100 Wall Mounted Pot Filler Faucets
Product Information
| Product Name | Wall Mounted Pot Filler Faucets |
|---|---|
| Model Number | 2311100 |
| Flow Rate | 1.8 GPM (Gallons per Minute) / 6.8 L/min (Liters per Minute) |
Product Usage Instructions
- To ensure proper installation, read all instructions completely
before beginning. - Read all warnings, care, and maintenance information.
- The faucet is designed for delivering cold water from a main
supply. - The faucet can be positioned above sinks or stoves, and the
articulated spout allows for convenient positioning above pots or
pans as required. - Installation Note: When installing on
plasterboard walls (not solid walls), ensure that appropriate
reinforcement is in place to ensure sufficient strength. - Flush pipes thoroughly before installation.
- Cleaning and Care: Take care when cleaning the
product. Although the finish is extremely durable, it can be
damaged by harsh abrasives or polish. To clean, simply wipe gently
with a damp cloth and blot dry with a soft towel. - On/Off Control: Rotate the handle 90 degrees
(1/4 turn) to control the water flow. Shut off both handle
cartridges when the faucet is not in use or left unattended.
Improper use or inadequate drainage below the faucet may cause
water damage. - The faucet has a G1/2 connection to the wall and a G1/2
connection to the faucet itself. - The dimensions of the faucet are as follows:
| Dimension | Size (inch/mm) |
|---|---|
| Height | 20.7” / 527mm |
| Width | 3.5” / 88mm |
| Depth | 10.4” / 263.5mm |
- Cold Water Connection Only: The faucet is
designed for cold water connection only. - Recommended Hole Size: The recommended hole
size for the faucet is 1/2 IPS inlets. - Installation Steps:
- Wrap plumber tape around pipe threads.
- Connect to 1/2 IPS supply line.
- Push flange on pot filler and mark the locating hole on the
wall. - Drill holes and insert plugs.
- Wrap plumber tape around pipe threads. Install the gasket and
the flange using the provided screws. - Place flange trim onto the faucet. Thread the faucet onto the
pipe and tighten securely, but do not overtighten. - Screw on the pot filler using a 1.5mm allen wrench to fasten it
to the flange. - Remove the aerator and turn the faucet handles to the full on
position. - Turn on the cold water supplies and flush the water lines for
one minute to remove any debris that could cause damage to internal
parts. - Check all connections for leaks at the indicated arrow.
Re-tighten if necessary, but do not overtighten. - If the faucet water flow is unsatisfactory due to extremely low
water pressure, replace the aerator to improve water flow. - If the faucet leaks out of the spout or handle, replace the
valve cartridge. Remove the handle, ring, and screw. Unscrew and
replace the valve cartridge using a 1.5mm hex key. Assemble in
reverse order. Line up the handles with valves in the closed
position before pushing handles into place.
Note: The product is compliant with California
water efficiency regulations and complies with California
Proposition 65 and the Federal Safe Drinking Water Act.
WALL MOUNTED POT FILLER FAUCETS
2311100
You may need
1.8GPM 6.8L/min
For easy installation of your faucet you will need:
To READ ALL the instructions completely before beginning.
To READ ALL warnings, care, and maintenanceinformation.
Application Faucet are designed for delivering cold water from a main supply. Faucet can be positioned above sinks or stoves and the articulated nature of the spout enables the outlet to be conveniently positioned above pots / pans as required.
Installation Note: When installing on plasterboard walls (not solid walls) it must be assured that an appropriate reinforcement is in place to ensure sufficient strength.
Flush pipes thoroughly!
Cleaning and Care Care should be given to the cleaning of this product. Although its finish is extremely durable, It can be damaged by harsh abrasives or polish. To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.
OFF
OPEN
Notice:
Simple on/off control by rotating handle 90 (1/4 turn) Shut off both handle cartridges when not in use or left unattended. Improper use or inadequate drainage below faucet may cause water damage.
G1/2″
7.8”(198mm)
unit:inch(mm)
Ø2.6” (65mm)
3.5” (88mm)
10.4”(263.5mm)
20.7”(527mm)
2.6”(67mm)
NPT 1/2 (To Wall)
0.9″(23mm) 2.2″(55mm)
G1/2 (To faucet)
M24x1mm 20
1.9″ (49mm) 0.85″ (21.5mm)
Notice:
Cold water connection only 1″ recommended hole size 1/2″ IPS inlets
M20x1.5 mm
1 WARNING: Connect to
2
Cold Water Only.
MIN1/2″ MAX 1.2″(30MM)
Wrap plumber tape around pipe threads Connect to 1/2″ IPS supply line.
3
Push flange on pot filler,mark locating hole on wall
4 Teflon tape
Ø15/64″ (Ø6MM)
12
Drill holes and insert plugs
5
Wrap plumber tape (1) around pipe threads. Install the gasket (2) and the flange (3) using the 4 screws provided.
6
Place flange trim (1) onto the faucet . Thread faucet ontopipe. Tighten securely, but do not overtighten.
Screw on pot filler Screw in screw by using an 1.5mm allen wrench to fasten pot filler to flange .
2 1
2
Remove aerator (1) and turn faucet handles (2) to the full on position. Turn on cold water supplies and flush water lines for one minute. Important: This flushes away any debris that could cause damage to internal parts. Check all connections at arrow for leaks. Re-tighten if necessary, but do not overtighten.
With 1.8 gpm are compliant with California water effi ciency regulations, Complies with California Proposition 65 and with the Federal Safe Drinking Water Act. In areas with extremely low water pressure causing the faucet water flow to be unsatisfactory , replace the aerator to improve the water flow in the faucet.
1 2 3 4
34
12
If faucet leaks out of spout or handle – Replace valve cartridge (4). Remove handle(1), ring(3)and screw (2). Unscrew and replace valve cartridge, 1.5 mm hex. Assemble in reverse order. Line up handles with valves in closed position before pushing handles into place.