9.250120 Provence Sink Mixer with Lever Handles
The Georgian Bathroom Collection Installation & User
Guide
Product Information
The Georgian Bathroom Collection is a 3 hole widespread bathroom
product that requires installation by a registered plumber. The
product has a maximum diameter of 1 3/4 inches and uses a 1/2 inch
NPT connection for the hot inlet. The recommended working pressure
for the product is between 1 bar/15psi and 5 bar/75psi, with ideal
performance obtained when hot and cold pressures are equal. The
product comes with ceramic disc valves as standard and requires
occasional cleaning with warm soapy water to maintain the plated
finish in good condition.
Product Usage Instructions
Before proceeding with the installation, it is recommended to
flush the plumbing system. Once unpacked, remove the large and
small base seals, rosette, hood and lever, securing nut, clamp
plate, pop-up, and top waste ready for installation.
- Spout Installation: Secure the spout with the
provided box spanner, making sure all connections are firmly
tightened. - Hood & Lever Installation: Install the
side valve from the underside of the work surface. Ensure the
connection for flexible hose is facing towards the spout. Leave the
backnut at the bottom of the valve body and place the valve body up
through the work surface hole. Before screwing down the hood &
lever, ensure that the orientation of levers is correct. Slide the
hood & lever over the top of the valve body just enough to see
if it is correctly orientated. Correct orientation can be achieved
by removing and turning the vernier insert. Screw backnut up to the
underneath of the work surface. Connect flexible hose as
shown. - Flexible Hose Connection: Connect the flexible
hose as shown and ensure that all connections are firmly
tightened. - Pop-Up Installation: Install the pop-up using
the O ring, top waste, foam seal, clamp bracket, pop-up shaft,
basin/bidet, pop-up rod, and rubber seal. Adjust the sink waste as
required.
After installation, wipe down the product after use to avoid
water spotting and mineral build-up. Avoid using proprietary
abrasive liquids, powders, or pads to clean the product, as this
will damage the plated finish and void your guarantee.
The Georgian Bathroom Collection Installation & User Guide
3 HOLE WIDESPREADS 6″ – 15″ CENTERS
· U.3712LS-2 · U.3712LSP-2
Ø1 1/8″ 1/2″ NPT Ø1 3/8″ HOLE
· U.3713X-2
1 3/4″ MAX
1/2″ NPT
Ø 2 3/8″
HOT IN
Ø 1 1/4″
11″ CENTER MAX
COLD IN
Temp Range: Min 1°C/34°F Max 85°C/185°F
Recommended Working Pressure: Min 1bar/15psi Max 5bar/75psi
Ideal performance obtained with equal hot & cold pressures.
Congratulations on the purchase of your Perrin & Rowe Bathroom Product. Correctly installed and with sensible care, this product will give you many years of trouble free service.
IMPORTANT INFORMATION
Before you proceed… We recommend you engage the services of a registered plumber to install this product.
For ease of possible future servicing, we also recommend the fitting of conveniently placed isolating valves.
In addition to the guide below it is essential that the written information overleaf is carefully read and understood.
Preparation Check Box for Installer
Flush the plumbing system before installing the bathroom product.
Once unpacked remove large & small base seals, rosette, hood & lever, securing nut, clamp plate, pop-up and top waste ready for installation.
1
Spout
Large Base Seal
WORK SURFACE
Clamp Plate
Base Ring Clamp Bolt
Securing Nuts
Box Spanner
Secure spout with supplied Box Spanner. Ensure all connections are firmly tightened
2
Hood & Lever
Rosette
Small Base Seal
Vernier Insert
Washer Backnut
Valve Body
WORK SURFACE
Flexible Hose
Sidevalve to be installed from underside of work surface as shown.
Ensure connection for flexible hose is facing towards spout.
Leave backnut at the bottom of valve body and place the valve body up through the work surface hole.
Before screwing down the hood & lever please make sure orientation of levers is correct. Slide the hood & lever over the top of valve body just enough to see if it is correctly orientated. Correct orientation can be achieved by removing and turning the vernier insert.
Screw backnut up to the underneath of the work surface.
Connect flexible hose as shown.
Hood & Lever
3
Connect flexible hose as shown.
Rosette
Small Base Seal
Connect HOT & COLD water supplies to the side valve inlets.
Ensure all connections are firmly tightened.
WORK SURFACE
Washer Backnut Valve Body
Flexible Hose
4
Pop-Up
O Ring
Top Waste
WORK SURFACE
Foam Seal
Clamp Bracket
Pop-Up Shaft
BASIN/BIDET
Pop-Up Rod. Rubber Seal
Bottom Waste
Adjusting Sink Waste
· Ensure that pop-up shaft is in position alongside pop-up rod.
· Shaft and rod can be cut if space is restricted.
· Secure pop-up using clamp bracket.
· Adjust position of clamp bracket to achieve maximum movement of pop-up shaft.
· Place pop-up into waste and adjust movement of pop-up shaft.
Please Note: Ceramic disc valves are fitted as standard to this mixer. Flow from FULLY OFF to FULLY ON is achieved by rotating the handles a quarter turn.
BEFORE USE
· Carefully check the installation for leaks. · If further building work is to be carried out in the vicinity, cover the tap with a plastic bag to avoid damaging
the finish. · Please ensure that the installation complies with local plumbing codes.
CARE & MAINTENANCE
Wipe down after use to avoid water spotting and mineral build up.
Occasional cleaning with warm soapy water, followed by a polish with a soft cloth is all that is required to keep the plated finish in good condition.
Do not use proprietary abrasive liquids, powders, or pads to clean the shower. Do not use any products with ammonia bleach or limescale remover. You will damage the plated finish and void your guarantee.