Perrin Rowe 9.250120 Provence Sink Mixer With Lever Handles User Guide

9.250120 Provence Sink Mixer with Lever Handles

The Georgian Bathroom Collection Installation & User
Guide

Product Information

The Georgian Bathroom Collection is a 3 hole widespread bathroom
product that requires installation by a registered plumber. The
product has a maximum diameter of 1 3/4 inches and uses a 1/2 inch
NPT connection for the hot inlet. The recommended working pressure
for the product is between 1 bar/15psi and 5 bar/75psi, with ideal
performance obtained when hot and cold pressures are equal. The
product comes with ceramic disc valves as standard and requires
occasional cleaning with warm soapy water to maintain the plated
finish in good condition.

Product Usage Instructions

Before proceeding with the installation, it is recommended to
flush the plumbing system. Once unpacked, remove the large and
small base seals, rosette, hood and lever, securing nut, clamp
plate, pop-up, and top waste ready for installation.

  1. Spout Installation: Secure the spout with the
    provided box spanner, making sure all connections are firmly
    tightened.
  2. Hood & Lever Installation: Install the
    side valve from the underside of the work surface. Ensure the
    connection for flexible hose is facing towards the spout. Leave the
    backnut at the bottom of the valve body and place the valve body up
    through the work surface hole. Before screwing down the hood &
    lever, ensure that the orientation of levers is correct. Slide the
    hood & lever over the top of the valve body just enough to see
    if it is correctly orientated. Correct orientation can be achieved
    by removing and turning the vernier insert. Screw backnut up to the
    underneath of the work surface. Connect flexible hose as
    shown.
  3. Flexible Hose Connection: Connect the flexible
    hose as shown and ensure that all connections are firmly
    tightened.
  4. Pop-Up Installation: Install the pop-up using
    the O ring, top waste, foam seal, clamp bracket, pop-up shaft,
    basin/bidet, pop-up rod, and rubber seal. Adjust the sink waste as
    required.

After installation, wipe down the product after use to avoid
water spotting and mineral build-up. Avoid using proprietary
abrasive liquids, powders, or pads to clean the product, as this
will damage the plated finish and void your guarantee.

The Georgian Bathroom Collection Installation & User Guide

3 HOLE WIDESPREADS 6″ – 15″ CENTERS

· U.3712LS-2 · U.3712LSP-2

Ø1 1/8″ 1/2″ NPT Ø1 3/8″ HOLE
· U.3713X-2

1 3/4″ MAX

1/2″ NPT

Ø 2 3/8″

HOT IN

Ø 1 1/4″

11″ CENTER MAX

COLD IN

Temp Range: Min 1°C/34°F Max 85°C/185°F
Recommended Working Pressure: Min 1bar/15psi Max 5bar/75psi
Ideal performance obtained with equal hot & cold pressures.

Congratulations on the purchase of your Perrin & Rowe Bathroom Product. Correctly installed and with sensible care, this product will give you many years of trouble free service.
IMPORTANT INFORMATION

Before you proceed… We recommend you engage the services of a registered plumber to install this product.

For ease of possible future servicing, we also recommend the fitting of conveniently placed isolating valves.

In addition to the guide below it is essential that the written information overleaf is carefully read and understood.

Preparation Check Box for Installer
Flush the plumbing system before installing the bathroom product.

Once unpacked remove large & small base seals, rosette, hood & lever, securing nut, clamp plate, pop-up and top waste ready for installation.

1

Spout

Large Base Seal

WORK SURFACE

Clamp Plate

Base Ring Clamp Bolt

Securing Nuts

Box Spanner

Secure spout with supplied Box Spanner. Ensure all connections are firmly tightened

2

Hood & Lever

Rosette
Small Base Seal
Vernier Insert
Washer Backnut
Valve Body

WORK SURFACE

Flexible Hose

Sidevalve to be installed from underside of work surface as shown.
Ensure connection for flexible hose is facing towards spout.
Leave backnut at the bottom of valve body and place the valve body up through the work surface hole.
Before screwing down the hood & lever please make sure orientation of levers is correct. Slide the hood & lever over the top of valve body just enough to see if it is correctly orientated. Correct orientation can be achieved by removing and turning the vernier insert.
Screw backnut up to the underneath of the work surface.
Connect flexible hose as shown.

Hood & Lever

3

Connect flexible hose as shown.

Rosette
Small Base Seal

Connect HOT & COLD water supplies to the side valve inlets.
Ensure all connections are firmly tightened.

WORK SURFACE

Washer Backnut Valve Body
Flexible Hose

4

Pop-Up

O Ring

Top Waste

WORK SURFACE

Foam Seal

Clamp Bracket
Pop-Up Shaft

BASIN/BIDET

Pop-Up Rod. Rubber Seal

Bottom Waste

Adjusting Sink Waste
· Ensure that pop-up shaft is in position alongside pop-up rod.
· Shaft and rod can be cut if space is restricted.
· Secure pop-up using clamp bracket.
· Adjust position of clamp bracket to achieve maximum movement of pop-up shaft.
· Place pop-up into waste and adjust movement of pop-up shaft.
Please Note: Ceramic disc valves are fitted as standard to this mixer. Flow from FULLY OFF to FULLY ON is achieved by rotating the handles a quarter turn.

BEFORE USE
· Carefully check the installation for leaks. · If further building work is to be carried out in the vicinity, cover the tap with a plastic bag to avoid damaging
the finish. · Please ensure that the installation complies with local plumbing codes.

CARE & MAINTENANCE
Wipe down after use to avoid water spotting and mineral build up.
Occasional cleaning with warm soapy water, followed by a polish with a soft cloth is all that is required to keep the plated finish in good condition.
Do not use proprietary abrasive liquids, powders, or pads to clean the shower. Do not use any products with ammonia bleach or limescale remover. You will damage the plated finish and void your guarantee.

References