Orion Instruments Mt Hydraulic Diaphragm Switch Instructions

MT Hydraulic Diaphragm Switch

Product Information:

The MD/MT Hydraulic Diaphragm Switch MT is a pressure capsule
used in hydraulic systems. It is designed to measure and control
pressure in industrial applications. The wetted parts of the
pressure capsule are made of high-quality materials to ensure
durability and reliability.

Product Usage Instructions:

  1. Installation:

    Refer to the installation drawing provided in the user manual
    for proper installation of the MD/MT Hydraulic Diaphragm Switch MT.
    Ensure that all connections are securely tightened to prevent
    leaks.

  2. Pressure Ports:

    The pressure ports of the switch are brazed with a flange.
    Connect the appropriate hydraulic lines to these ports. The wetted
    parts of the pressure capsule are specifically designed to handle
    hydraulic fluids.

  3. Cable Entry:

    The MD/MT Hydraulic Diaphragm Switch MT has a cable entry point
    of 1/2 NPT or M20x1.5. Choose the appropriate cable entry option
    based on your specific requirements.

  4. Pressure Port:

    The pressure port size of the switch is 1/4 BSP (F). Use
    compatible fittings to connect the switch to the hydraulic
    system.

  5. Dimensions:

    The approximate dimensions of the MD/MT Hydraulic Diaphragm
    Switch MT are as follows:

  • Length: 98.0 mm (3.85 inches)
  • Width: 130.0 mm (5.11 inches)
  • Height: 87 mm (3.42 inches)
  • Cable Entry A/F: 19 mm (0.74 inches)
  • Pressure Port Length: 149 mm (5.86 inches)
  • Pressure Port A/F: 18 mm (0.70 inches)

For further information and detailed instructions, please refer
to the user manual provided with the MD/MT Hydraulic Diaphragm
Switch MT. If you have any questions or need assistance, please
contact our customer support.

MD/MT HYDRAULIC DIAPHRAGM SWITCH MT

PRESSURE CAPSULE DETAILS

Note : wetted parts are mentioned in italics.
INSTALLATION DRAWING
98.0 (3.85)

MOUNTING HOLES 2NOS Ø7
(0.27)

No. Description 1. Transfer Pin (SS) 2. Cushioning Pad 3. `O’ ring (PTFE®) 4. Diaphragm (PTFE®) 5. Pressure Housing (SS316)
1 2
3 4 5
*Pressure ports are brazed with flange
130.0 (5.11)

87 (3.42)

51 (2.0)

51 (2.0)

31 (1.22)

136 (5.35)

48.0 (1.88)

Cable Entry 1/2″ NPT or M20x1.5
A/F 19 (0.74)

Pressure Port 1/4″ BSP (F)

149 (5.86)

18 (0.70)
APPROX. DIMENSIONS IN

mm inches