LLP100 Power Supply
Product Information:
- Product Name: LLP100 CV+CC
- Manufacturer: Shenzhen SANPU Intelligent Technology Co.,
Ltd. - Features:
- 100% full load burn-in test
- Universal AC input
- Small size and high efficiency
- Conforms to EMC EN5502 GB9254
- Built-in EMI filter with tiny ripple
- Complies with safety standards UL60950 GB4943 EN60850
- Protection against short circuit, over voltage, over load, and
temperature
Product Usage Instructions:
The LLP100 CV+CC is a power supply unit that provides a
regulated output voltage for various applications. Please follow
the instructions below for proper usage:
- Check the model number on the product to ensure it is the
correct version for your requirements. The available models are
LLP100-W1V12 (12V output) and LLP100-W1V24 (24V output). - Connect the AC input to a universal power source within the
specified input voltage range. - Ensure the AC input current is within the recommended
limits. - Connect the output of the power supply to your device or
circuit, making sure to match the required voltage (12V or 24V) and
current specifications. - Verify that the output voltage error is within acceptable
limits. If not, please contact the manufacturer for
assistance. - Monitor the output current to ensure it stays within the rated
output current range. Do not exceed the maximum output power. - Check for any ripple and noise in the output and take
appropriate measures if necessary. - Ensure proper power factor by maintaining the recommended input
voltage range. - During cold start, monitor the current and ensure it is within
expected levels. Also, note the start, rise, and hold time for
reference. - Monitor the static current to ensure it is within acceptable
limits. - Take note of the overload protection feature, which safeguards
against excessive current. - Be aware of the short circuit protection and the over
temperature protection features to prevent any damage to the power
supply or connected devices.
Environment and Safety Standards:
- Working Temperature: [Provide temperature range]
- Working Humidity: [Provide humidity range]
- Storage Temperature: [Provide temperature range]
- Storage Humidity: [Provide humidity range]
- Withstand Voltage: [Provide voltage]
- Insulation Resistance: [Provide resistance]
- Safety Standards: [Provide safety standards]
- EMC Standards: [Provide EMC standards]
LLP100 CV+CC
Shenzhen SANPU Intelligent Technology Co., Ltd.
FEATURES 100% full load burn-in test Universal AC input Small size and high efficiency Conform to EMC EN5502 GB9254
Built-in EMI filter with tiny ripple Comply with the safety standards UL60950 GB4943 EN60850 Protection: short circuit/over Voltage/over/load temperature
OUTPUT INPUT
MODEL Rated Voltage No-load voltage
Output voltage error Rated output current Output current range Rated output power Maximum Output Power
Ripple and Noise POWER FACTOR(Typ.) Input Voltage Range
AC input current Efficiency
Cold start current Start, rise, hold time
Static current
Overload protection
PROTECTION
Overcurrent protection Short circuit protection
Over temperature protection
ENVIRONMENT SAFETY
STANDARDS
WORKING TEMP, HUMIDITY WORKING HUMIDITY
STORAGE TEMP, HUMIDITY WITHSTAND VOLTAGE Insulation resistance Safety Standards EMC standards
LLP100-W1V12
LLP100-W1V24
12V
24V
<12.6V 12V±5% 8.3A±10% 08.3A
100W
<24.6V 24V±3% 4.2A±10% 04.2A
100W
105W
105W
120mVp-p 0.6
150mVp-p 0.6
AC 110240V; 47Hz63Hz 1.0A/AC 115V; 0.5A/AC 230V
86%
30A/AC230V
2000ms,50ms,20ms
<10mA/240VAC
105-120% of rated power 100W Hiccup mode, the circuit returns to normal after the abnormal condition is removed
Circuit protection is when the maximum voltage exceeds the circuit; when the abnormality is removed, the circuit returns to normal.
Short circuit more than 3 times, no damage, can automatically recover.
105 start protection; circuit output normal after temperature returns to normal
-206020%90%RH
-408510%95%RH
10500Hz 2G 10.min/1 cycle Time duration 60 minutes Each axis
AC/DC: 3KV
Between input and output 100M ohm s/DC500V
EN62368;EN61347
EN55032
Tel: 086 755 2306 0905
Fax: 086 755 2304 1269
Website: www.smpspower.com
Add: 5th Floor, B3 Building, Huafeng Shiji Industrial park, Hangcheng Road, Xixiang, Bao’an district, Shenzhen P.R.C.
LLP100 CV+CC
Shenzhen Sanpu Intelligent Technology Co., Ltd.
PACKAGE
Weight Packing
Product Net Weight Kg Carton Size: 395*295*210mm 100PCS/CTNS
1. all parameters are measured at AC220V voltage input, rated load and 25°C, when not specified otherwise. Special Instructions 2. ripple and noise voltages are measured at the end of a 20 MHz bandwidth oscilloscope with 12″ twisted pair plus 0.1
uF and 47 uF.
Structural Parameters and Guidance for use: Power Supply Appearance and Dimensions.
Derating Curve
Static Characteristics(12V)
REMARKS:
1, The above mentioned data were measured at 230VAC input and 25°C. 2, Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3, Cut the AC input before checking any mal-phenomenons. 4, Make sure the INPUT&OUPUT were in right situation before connected to power supply. 5, Be ware of high power pressure may caused by short circut when installing metal casing products. 6, Please contact us at [email protected] for further solution if any unforeable problem happens.
Tel: 086 755 2306 0905
Fax: 086 755 2304 1269
Website: www.smpspower.com
Add: 5th Floor, B3 Building, Huafeng Shiji Industrial park, Hangcheng Road, Xixiang, Bao’an district, Shenzhen P.R.C.