Velleman K4006 Power Supply User Manual

K4006 Power Supply

Product Information:

  • Total solder points: 36
  • Difficulty level: beginner 1 2 3 4 5 advanced
  • Power supply for K4004B and K4005B
  • K4006
  • ILLUSTRATED ASSEMBLY MANUAL H4006IP-1

Product Usage Instructions:

  1. Assembly Hints:
  • Make sure you have the right tools, including a basic
    multi-meter for some projects.
  • Always look for possible last minute manual updates indicated
    as ‘NOTE’ on a separate leaflet.
  • Soldering Hints:
    1. Mount the component against the PCB surface and carefully
      solder the leads.
    2. Make sure the solder joints are cone-shaped and shiny.
    3. Trim excess leads as close as possible to the solder
      joint.
  • Construction:
  • Connection:
    • Refer to the provided table for the connection details based on
      the specific product model (K4004B, K4005B).
    • Ensure correct polarity for LEDs, bridge rectifier, and
      electrolytic capacitors.

    For any further assistance or inquiries, please contact VELLEMAN
    Components NV:

    Address: Legen Heirweg 33, 9890 Gavere, Belgium, Europe

    Website: www.velleman.be,
    www.velleman-kit.com

    Product Support: +32 410329 311575

    Total solder points: 36 Difficulty level: beginner 1 2 3 4 5 advanced
    Power supply for K4004B and K4005B
    K4006

    ILLUSTRATED ASSEMBLY MANUAL

    H4006IP-1

    Assembly hints
    1. Assembly (Skipping this can lead to troubles ! ) Ok, so we have your attention. These hints will help you to make this project successful. Read them carefully.
    1.1 Make sure you have the right tools:
    · A good quality soldering iron (25-40W) with a small tip. · Wipe it often on a wet sponge or cloth, to keep it clean; then apply solder to the tip, to give it a wet look. This is called `thinning’ and will
    protect the tip, and enables you to make good connections. When solder rolls off the tip, it needs cleaning. · Thin raisin-core solder. Do not use any flux or grease. · A diagonal cutter to trim excess wires. To avoid injury when cutting excess leads, hold the lead so they
    cannot fly towards the eyes. · Needle nose pliers, for bending leads, or to hold components in place. · Small blade and Phillips screwdrivers. A basic range is fine.
    0.000
    For some projects, a basic multi-meter is required, or might be handy
    1.2 Assembly Hints :
    Make sure the skill level matches your experience, to avoid disappointments. Follow the instructions carefully. Read and understand the entire step before you perform each operation. Perform the assembly in the correct order as stated in this manual Position all parts on the PCB (Printed Circuit Board) as shown on the drawings. Values on the circuit diagram are subject to changes. Values in this assembly guide are correct* Use the check-boxes to mark your progress. Please read the included information on safety and customer service
    * Typographical inaccuracies excluded. Always look for possible last minute manual updates, indicated as `NOTE’ on a separate leaflet.
    2

    1.3 Soldering Hints : 1- Mount the component against the PCB surface and carefully solder the leads
    2- Make sure the solder joints are cone-shaped and shiny 3- Trim excess leads as close as possible to the solder joint

    Assembly hints

    REMOVE THEM FROM THE TAPE ONE AT A TIME !
    AXIAL COMPONENTS ARE TAPED IN THE CORRECT MOUNTING SEQUENCE !
    You will find the colour code for the resistances and the LEDs in the HALG (general manual) and on our website: http://www.velleman.be/common/service.aspx
    3

    Construction
    1. 1W Resistors
    R…

    4. Fuse + fuseholder
    F…

    R1 : 2K7 (2 – 7 – 2 – B) R2 : 2K7 (2 – 7 – 2 – B)
    2. LEDs. Watch the polarity!

    LD1 LD2

    CATHODE

    LD…

    F1 : 6,3A slow F2 : 6,3A slow
    5. PCB mounting tab
    -V (2x) GND (2x) +V (2x)

    3. Screw terminal
    J1 4

    6. Bridge rectifier B1 : RS603
    (6A – 200V)
    Watch the polarity!

    7. Electrolytic Capacitors. Watch the polarity !
    C3 : 10.000µF C4 : 10.000µF
    C…
    C1 : Optional C2 : Optional
    Ordernr C1 & C2 : 10000LPOJ
    8. Flat receptacle

    6 x

    Wire Insulation sleeve Flat receptacle

    9. Connection +V
    K4006 GND -V
    Needs transformer :
    K4005B K4005B K4005B K4004B K4004B K4004B

    Connection

    +V GND -V

    K4004B, K4005B

    Speaker 2 x 8 ohm 2 x 4 ohm 1 x 8 ohm

    Power supply 2 x 30VAC / 225VA 2 x 21VAC / 300VA 2 x 21VAC / 300VA

    Transformer Type 22530 Type 30021 Type 30021

    2 x 8 ohm

    2 x 18VAC / 160VA

    Type 16018

    2 x 4 ohm

    2 x 18VAC / 225VA

    Type 22518

    1 x 8 ohm

    2 x 18VAC / 225VA

    Type 22518

    5

    PCB 10. PCB layout.
    6

    11. Diagram

    Diagram 7

    VELLEMAN Components NV Legen Heirweg 33 9890 Gavere Belgium Europe www.velleman.be
    www.velleman-kit.com
    Modifications and typographical errors reserved © Velleman Components nv. H4006IP – 2004 – ED1