Jonathan Y Jyl7204a 24 Inch Chandelier Instruction Manual

JYL7204A 24 Inch Chandelier

Product Information

The JYL7204A lighting fixture is a ceiling-mounted lamp that
comes with a mounting bracket, canopy, wire connectors, wire,
driver, regulator, and lamp body. It is 24 x 24 x 12-72 1/2 inches
in size. The external flexible cable or cord of this lamp cannot be
replaced if damaged. The product should be assembled on a soft
surface to prevent scratching the finish during assembly.

Part and Hardware List

Part List:

  • A – Mounting screw
  • B – Mounting bracket
  • C – Machine screw
  • D – Wire connector
  • E – Driver
  • F – Wire
  • G – Regulator
  • H – Canopy
  • I – Lamp body

Hardware List:

  • 6x wire connectors (D)
  • 4x wire (F)
  • 2x regulator (G)
  • 2x canopy (H)
  • 1x driver (E)
  • 2x mounting screws (A)
  • 1x mounting bracket (B)

Product Usage Instructions

WARNING: We recommend installation of this lighting
fixture be done by a licensed electrician. Switch off the main
electrical supply from the main fuse box/circuit breaker before
installation. Inspect item carefully before attempting to install.
If there is any damage or obvious defect, do not install. Item may
not be returned once it has been installed.

Preparation

Before beginning assembly of the product, make sure all parts
are present. Compare parts with package contents list and hardware
contents list. If any part is missing or damaged, do not attempt to
assemble the product. Estimated assembly time is 20 minutes.

Assembly Steps

  1. Take out machine screw (A) and mounting bracket (B) from canopy
    (H).
  2. Fix the mounting bracket (B) to the outlet box with machine
    screw (C).
  3. Make wire connections, with wire connectors (D), following the
    reference chart listed in the instructions.
  4. Fix the ceiling canopy (H) so that the screws protruding from
    the mounting bracket go into the holes in the canopy, then secure
    it with the machine screw (A).
  5. Use regulator (G) to adjust the length of wire, put the wire
    into regulator (G) can be shorter, press regulator (G) and take out
    wire from regulator (G) can be longer.
  6. Turn on switch, light up.

Care and Maintenance

NOTICE & IMPORTANT SAFETY INSTRUCTIONS:

  • Please make sure that you have all parts indicated before you
    begin assembly of this item.
  • To reduce the risk of fire, electrical shock, or injury to
    persons or property, please follow the guidelines below for safe
    use and installation.
  • The external flexible cable or cord of this lamp cannot be
    replaced. If the cord is damaged, the lamp shall be destroyed.

Grounding Instructions

For installation in the United States: Wrap ground wire
from outlet box around green on mounting bracket, no less than 2
inches from wire end. Tighten ground screw. If fixture is supplied
with a ground wire, connect to outlet ground wire with a wire
connector.

For installation in Canada: If fixture is supplied with
ground wire, wrap ground wire around green grounding screw on
mounting bracket. Tighten ground screw.

WARNING
WE RECOMMEND INSTALLATION OF THIS LIGHTING FIXTURE BE DONE BY A LICENSED ELECTRICIAN. WARNING *** SWITCH OFF THE MAIN ELECTRICAL SUPPLY FROM THE MAIN FUSE BOX/CIRCUIT BREAKER BEFORE INSTALLATION. INSPECT ITEM CAREFULLY BEFORE ATTEMPTING TO INSTALL. IF THERE IS ANY DAMAGE OR OBVIOUS DEFECT, DO NOT INSTALL. ITEM MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED.
CARE AND MAINTENANCE
To clean the outside of the fixture, use a dry or slightly dampened clean cloth (use clean water, never a solvent) to wipe the surface of the fixture. To clean the inside of the fixture, first disconnect power to the fixture by turning off the circuit breaker or by removing the fuse at the fuse box. Next, use a dry or slighly damperned clean clorth (use clean water, never a solvent) to wipe the interior surface of the fixture. Do not use any cleaners with chemical, solvents or harsh abrasives. Use only a dry soft cloth to dust or wipe carefully.
NOTICE& IMPORTANT SAFETY INSTRUCTIONS
* Please make sure that you have all parts indicated before you begin assembly of this item * This item should be assembled on a soft surface to prevent scratching the finish during assembly * To reduce the risk of fire, electrical shock or injury to persons or property, please follow the guideline below for safe use and installation *The external flexible cable or cord of this lamp cannot be replaced If the cord is damaged, the lamp shall be destroyed
Part List and Hardware List

PIECE DESCRIPTION

A

mounting screw

B

mounting bracket

C machine screw

PICTURE

QUANTITY PIECE DESCRIPTION

2X

F

wire

1X

G

regulator

2X

H

canopy

PICTURE

QUANTITY 6X 4X 1X

D wire connector

3X

I

lamp body

2X

E

driver

1X

Model#: JYL7204A Product Dimensions: 24 x 24 x 12-72″

1/2

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product. Estimated Assembly Time: 20 minutes.

1.Take out machine screw (A) and mounting bracket (B) from canopy (H) 2. Fix the mounting bracket(B) to the outlet box with machine screw(C).

3. Make wire connections, with wire connectors(D), following the reference chart listed below.

Connect, Hot, Black or Red Outlet Supply Wire to:

Connect, Neutral, White Outlet Supply Wire to:

Black * Parallel Cord (round & smooth)
Clear, Brown, Gold or Black without Tracer stripes)

(colored

White * Parallel Cord (square & ridged)
Clear, Brown, Gold or Black with Tracer (colored stripes)

Insulated Wire (not green) with copper metal conductor

Insulated Wire (not green) with Silver metal conductor.

*Note: When parallel wire ( SPT I & SPT II ) is used. The neutral wire is square shaped
and ridged and the hot wire will be round in shape and smooth. ( See Illustration on left. )
Grounding Instructions: a) For installation in the United States: Wrap ground wire from outlet box around green
on mounting bracket, no less than 2″ from wire end. Tighten ground screw. If fixture is supplied with a ground wire, connect to outlet ground wire with a wire connector. b) For installation in Canada: If fixture is supplied with ground wire, wrap ground wire around green grounding screw on mounting bracket. Tighten ground screw.
4. Fix the ceiling canopy (H) , so that the screws protruding from the mounting bracket go into the holes in the canopy,then secure it with the machine screw (A).
5. Use regulator (G) to adjust long of wire, put the wire into regulatior(G) can be shorter, press regulatior (G) and take out wire from regulator (G) can be longer.
6. Turn on switch, light up.

ENJOY YOUR LAMP