Lennox Kg-kc-kh Landmark And Raider Rooftop Units User Manual

KG-KC-KH Landmark and Raider Rooftop Units

Product Information: Commercial Training Toolbox Tips

The Commercial Training Toolbox Tips is a resource for Lennox
Landmark and Raider Rooftop Units that have a factory or
field-installed economizer with a Honeywell W7220 controller. An
economizer uses a combination of sensible and enthalpy sensors to
determine when outside air is suitable for free cooling. The type
and number of sensors depends on the controller.

Honeywell Jade W7220 Economizer Controller Sensors

The Honeywell Jade W7220 Economizer Controller Sensors are used
for KG/KC/KH and ZG/ZC/ZH Units with a Honeywell W7220 Economizer
Controller. The sensors include:

  • Enthalpy Return Air Sensor (11G21): Measures return air
    enthalpy for dual enthalpy (differential enthalpy) functions.
    Compares with Outside Air enthalpy sensor for control.
  • Sensible Return Air Sensor (11G26): Measures return air
    temperature for differential sensible control. Measures outside air
    enthalpy for dual enthalpy (differential enthalpy) functions. In
    single enthalpy applications, it compares the enthalpy to the ES
    Curve Setting to enable free cooling. Enables free cooling
    operation when conditions are favorable.
  • Sensible Outside Air Sensor (11G26): Measures outside air
    temperature for single and differential sensible control.
  • Sensible Discharge Air Sensor (11G26): Measures discharge air
    after the cooling coil.

Helpful Resources

For installation and service literature, visit
LennoxCommercial.com or LennoxPros.com. You can also access
self-service technical support with no wait times by downloading
the apps on the Lennox Commercial YouTube Channel and registering
for Technical Training Webinars.

Product Usage Instructions

To use the Commercial Training Toolbox Tips, follow the below
instructions:

  1. Ensure that your Lennox Landmark or Raider Rooftop Unit has a
    factory or field-installed economizer with a Honeywell W7220
    controller.
  2. Refer to the Honeywell Jade W7220 Economizer Controller Sensors
    section to understand the type and number of sensors required for
    your unit.
  3. Use the sensors to determine when outside air is suitable for
    free cooling and enable free cooling operation when conditions are
    favorable. The specific instructions for using the sensors will
    depend on the type of sensor and the controller being used.
  4. If you require additional assistance, visit
    LennoxCommercial.com or LennoxPros.com for installation and service
    literature or access self-service technical support through the
    apps on the Lennox Commercial YouTube Channel and Technical
    Training Webinars.

COMMERCIAL TRAINING TOOLBOX TIPS
Economizer Setup for KG/KC/KH and ZG/ZC/ZH Units with a Honeywell W7220 Economizer Controller
Applies to Lennox Landmark and Raider Rooftop Units that have a factory or field-installed economizer with a Honeywell W7220 controller
Helpful Resources 1. Installation and service literature on LennoxCommercial.com or LennoxPros.com
An economizer uses a combination of sensible and enthalpy sensors to determine when outside air is suitable for free cooling. The type and number of sensors depends on the controller.

Self-Service Technical Support with No Wait Times Click on the black logos below to download these apps

View Service Videos Lennox Commercial YouTube Channel Download all Training Toolbox Tips Register for Technical Training Webinars
COM-01-044

Honeywell Jade W7220 Economizer Controller Sensors

Type Sensor

Cat # Action

Image

Enthalpy Return Air

11G21

Measures return air enthalpy for dual enthalpy(differential enthalpy) functions. Compares with Outside Air enthalpy sensor for control.

Sensible Return Air

11G26

Measures return air temperature for differential sensible control.

Measures outside air enthalpy for dual enthalpy(differential enthalpy) functions.

In single enthalpy applications, it compares Enthalpy Outside Air 11G21 the enthalpy to the ES Curve Setting to enable
free cooling.
Enables free cooling operation when conditions are favorable.

Sensible Outside Air

11G26

Measures outside air temperature for single and differential sensible control.
Enables free cooling operation when conditions are favorable.

Sensible Discharge Air 11G26 Measures discharge air after the cooling coil.