T0566 Kinzie 1 Light 19 In Textured Black Outdoor Wall Light
Product Information: ASSEMBLY AND INSTALLATION
INSTRUCTIONS
The product is a fixture that needs to be assembled and
installed. It comes with a hardware package that includes a
mounting plate unit, mounting screws, wire connector, set screw,
outlet box, photocell backplate, house grounding wire, green
grounding screw, fixture grounding wire, and fixture wire. The
fixture can hold a max 60W Type T10 bulb (not included). The
installation process involves turning off the main power at the
circuit breaker, attaching the mounting plate unit to the outlet
box, securing the backplate of the fixture to the mounting plate
unit, inserting the glass panels into the bottom clips of the
fixture, and installing the bulb. The product can also be installed
with a dimmer switch when the photocell is disconnected.
Product Usage Instructions:
- Before installing the fixture, consult local electrical codes
for wiring and grounding requirements. - Turn off the main power at the circuit breaker before
installing the fixture. - Unscrew the two set screws (D) and remove the mounting plate
unit (A) from the backplate. - Attach the mounting plate unit (A) to the outlet box using two
mounting screws (B). - Secure the two set screws (D) from the side hole of the
backplate into the hole in the side of the mounting plate unit
(A). - Caulk completely around where the backplate meets with the wall
surface using silicone caulking compound to prevent water from
seeping into the outlet box. - Insert the glass panels into the bottom clips of the fixture
then press the top clips to secure them. - Install a max 60W Type T10 bulb (not included) and check the
relamping label at the socket area or packaging for the maximum
wattage allowed. - Turn on the main power at the circuit breaker.
Optional Installation: Disconnect Dusk-to-Dawn Photocell
- Turn off the main power at the circuit breaker before starting
installation. - Loosen the wire connector connected with the wires from
photocell. Do not remove the photocell to prevent water from
seeping into the outlet box. - Take a white pigtail and black pigtail and make wire
connections using wire connector (C). - The black wire from the fixture to one end of the black
pigtail. - The white wire from the fixture to one end of the white
pigtail. - The other end of the black pigtail to the black wire from the
power source. - The other end of the white pigtail to the white wire from the
power source. - Put all wires back into the backplate of the fixture.
- Turn on the main power at the circuit breaker.
If any parts are damaged or missing, they can be re-ordered
using the spare parts list provided.
ASSEMBLY AND INSTALLATION INSTRUCTIONS
T0566 / T0567 / T0628 / T0645
WARNING: Turn off the main power at circuit breaker before installing fixture. AVERTISSEMENT: Coupez la source d’alimentation principale au panneau central de disjoncteurs avant d’installer le luminaire.
NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS.
Hardware Package (included):
Mounting Plate Unit (A)
Mounting Screw (B)
Wire Connector (C)
Set screw (D)
Outlet Box
Photocell Backplate
House Grounding Wire Green Grounding Screw Mounting Plate Unit (A)
Mounting Screw (B) Fixture Grounding Wire
Wire Connector (C) Fixture Wire
Installation Steps
Turn off the power at fuse or circuit box
1. Unscrew the two set screws (D) and remove the mounting plate unit (A) from the backplate.
2. Attach the mounting plate unit (A) to the outlet box by using two mounting screws (B).
Socket Glass Panel
Fixture Set Screw (D)
Max.60W Type T10 Bulb (not included)
Page 1 / 3
220316
3. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows: · Connect the hot wire (usually black insulation) from the fixture to the black wire from the power source. · Connect the neutral wire (usually white insulation) from the fixture to the white wire from the power source. · Attach the fixture grounding wire (usually green insulation or bare wire) to the mounting plate unit (A) with the green grounding screw, then connect it to the house grounding wire with the wire connector (C). Carefully put all of the wires back into the outlet box.
4. Attach the backplate of the fixture to the mounting plate unit (A) by aligning holes, secure the two set screws (D) from the side hole of the backplate into the hole in the side of the mounting plate unit (A). Note: With silicone caulking compound, caulk completely around where the backplate meets with the wall surface to prevent water from seeping into the outlet box.
5. Gently insert the glass panels into the bottom clips of fixture
then press the top clips to secure the glass panels. (See Fig.1 and Fig.2)
6. Install the bulb (not included). Check relamping label at socket area or packaging for maximum wattage allowed.
Turn on the power at fuse or circuit box
Fixture
Glass Panel
Bottom Clip
Fig.1
Glass Panel
Top Clip Fixture
Fig.2
Optional Installation: Disconnect Dusk-to-Dawn Photocell
IMPORTANT: Compatible with dimmer when photocell is disconnected. * Requires dimmable bulb and compatible dimmer switch.
Photocell Black wires From Photocell White Wires From Photocell Red Wires From Photocell
Wire Connector
Wires From Fixture Wires From Main Power
Pigtail
Wires From Fixture
White Pigtail
Fig.3
Wire Connector (C)
Fig.4
1. Turn off the power at the fuse or circuit box before starting installation.
2. Loosen the wire connector connected with the wires from photocell. (See Fig.3) Note: Do not remove the photocell to prevent water from seeping into the outlet box.
3. Take a white pigtail and black pigtail and make wire connections using wire connector (C): (See Fig.4) a. The black wire from the fixture to one end of the black pigtail. b. The white wire from the fixture to one end of the white pigtail. c. The other end of the black pigtail to the black wire from the power source. d. The other end of the white pigtail to the white wire from the power source. Put all wires back into the backplate of the fixture.
Turn on the power at fuse or circuit box.
Page 2 / 3
220316
The following parts are available for re-order if damaged or missing. Spare Parts List:
Mounting Plate Unit (A) Mounting Screw (B) Wire Connector (C)
Set screw (D)
Mounting Hardware 6205MM (1SET) for T0566 / T0567 6446MM (1SET) for T0628 6503MM (1SET) for T0645
T0566 / T0628 Glass Panel X4 PCS 10151CS
T0567 Glass Panel X4 PCS 10152CS
T0645 Glass Panel X4 10292CG
B A
T0566 / T0628
A: 14-1/4″ B: 5″ C: 6″
T0567
T0645
A: 16-3/4″ B: 6″ C: 7″
A: 19″ B: 7″ C: 8″
C
Page 3 / 3
220316