American Lighting Association 71265-66 Harbor View 1-light Black Outdoor Wall Light Instruction Manual

71265-66 Harbor View 1-Light Black Outdoor Wall Light

Product Information

The product is a Model# 71265-66 fixture that is suitable for
wet location applications. It comes with a mounting plate, ground
screw, mounting screws, back plate, gaskets, screws, and a medium
base bulb. The fixture should be connected to an outlet box and the
electrical wires should be connected with connectors. The fixture
has a maximum wattage rating of 60 Watts, and the glass can be
replaced if needed.

Product Usage Instructions

  1. Ensure that the power is shut off at the fuse box or circuit
    breaker box before starting the installation.
  2. Remove the old fixture including the mounting hardware and
    carefully unpack the new fixture, laying out all the parts in a
    clear area.
  3. Attach the mounting plate to the outlet box using outlet box
    screws. The side of the mounting plate marked GND must face
    out.
  4. Connect the electrical wires as shown in Fig.2 with connectors,
    making sure that all wire connectors are secured. Connect the
    fixture’s ground wire to the outlet box’s ground wire or directly
    to the mounting plate using the green screw provided.
  5. Place the back plate over the mounting plate and secure it with
    two screws.
  6. To prevent moisture from entering the outlet box, use clear
    silicone sealant to outline the outside of fixture back plate where
    it meets the wall leaving a space at bottom to allow moisture a
    means to escape.
  7. To replace the glass, remove gaskets and loosen the screws to
    remove cover. Insert the new glass into the fixture frame from the
    bottom and secure the lower cover by screwing screws until tight
    and reinstalling gaskets on the lower cover.
  8. Install one medium base bulb up to 60 Watts, or CFL or LED
    equivalent, in accordance with the fixture specification. DO NOT
    EXCEED THE MAXIMUM WATTAGE RATING.
  9. Ensure that the installation is complete and return power to
    the outlet box. Test the fixture to ensure it is working
    correctly.

INSTALLATION INSTRUCTIONS
Model# 71265-66 READ AND SAVE THESE INSTRUCTIONS
W ARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

PREPARING FOR INSTALLATION (Fig. 1)

1. Shut off power at the fuse box or circuit breaker box and remove the

old fixture including the mounting hardware. 2. Carefully unpack your new fixture and lay out all the parts in a clear
area. Take care not to misplace any small parts necessary for installation.

Fig. 1

Mounting plate (1) (Part#A-020-108A) Ground screw (1) Mounting screws (2)

3. Attach mounting plate (B) using outlet box screws (F) to the outlet box

(A) (not supplied). The side of mounting plate marked “GND” must

face out. (Fig 1)

CONNECTING THE WIRES (Fig. 2)

B

4. Connect the electrical wires as shown in Fig.2 with connectors (E),

making sure that all wire connectors are secured. If your outlet box (A)

has a ground wire (green or bare copper), connect the fixture’s ground

G

wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (B) using the green screw (D) provided. After the wires

CD

E

are connected, carefully tuck them inside the outlet box (A).

FINISHING THE INSTALLATION (Fig. 1)

5. Place the back plate (G) over mounting plate (B) and secure with two

screws (C). Tighten until snug (Fig 1).

6. To prevent moisture from entering the outlet box (A) and causing a

short, use clear silicone sealant to outline the outside of fixture back

plate (G) where it meets the wall leaving a space at bottom to allow

F

moisture a means to escape. (Fig.3) 7. To replace the glass, remove gaskets (M, 8pcs) and loosening the

I

screws (L, 8pcs) to remove cover (K). Insert the new glass (J) into the

fixture frame from the bottom. Secure the lower cover (K) by screwing

screws (L, 8pcs) until tight and reinstalling gaskets (M, 8pcs) on the

J

lower cover (K).

8. Install (1) one medium base bulb (I) up to 60 Watts, or CFL or LED

equivalent (not included), in accordance with the fixture specification.

K

(DO NOT EXCEED THE MAXIMUM WATTAGE RATING) (NE PAS

DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)

L

9. This fixture is ETL listed for wet location applications.

M

Your installation is now complete. Return power to the outlet box and test the fixture.

F ig.2
FIXTURE WIRES BLACK

FIXTURE WIRES WHITE

FIXTURE WIRES GREEN OR BARE
COPPER (GROUND)

HOUSE
WIRES BLACK (HOT)

HOUSE
WIRES WHITE
(NEUTRAL)

HOUSE
WIRES GREEN OR
BARE COPPER(GROUND)

Fig 3

“CAUTION-RISK OF FIRE CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR”
ATTENTION ­ RISQUE D’INCENDIE, CONSULTER UN ÉLECTRICIEN QUALIFIÉ POUR VOUS ASSURER QUE LES CONDUCTEURS DE LA DÉRIVATION SONT ADÉQUATS.

Backplate

Caulking

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals