T0638 Outdoor Wall Light
Product Information:
The T0638/T0639 fixture is a wall-mounted light that requires a
Type A bulb (maximum wattage of 60W, not included). The fixture
comes with a hardware package that includes a mounting plate unit,
mounting screw, wire connector, bolt nut, and rubber pad. The
fixture also has a grounding wire and a green grounding screw for
safety. The installation process should be done in accordance with
local electrical codes for wiring and grounding requirements. The
fixture should be turned off from the main power at the circuit
breaker before installation.
Product Usage Instructions:
- Consult local electrical codes for wiring and grounding
requirements before installing the fixture. - Turn off the main power at the circuit breaker before
installation. - Unscrew the two bolt nuts (D) and remove the two rubber pads
(E) and the mounting plate unit (A) from the backplate. - Attach the mounting plate unit (A) to the outlet box by using
two mounting screws (B). Adjust the length of the preinstalled
headless screws if necessary. Note: Make sure that two headless
screws are lined up horizontally to make the fixture level. - Install the bulb (not included). See relamping label at socket
area or packaging for maximum wattage allowed. - Attach the backplate of the fixture to the mounting plate unit
(A) by aligning and inserting the two headless screws into set
holes on backplate, then secure it with two rubber pads (E) and two
bolt nuts (D). Note: With silicone caulking compound, caulk
completely around where the backplate meets with the wall surface
to prevent water from seeping into the outlet box. - Turn on the power at the circuit breaker.
Note: The fixture should be caulked completely around where the
backplate meets with the wall surface to prevent water from seeping
into the outlet box. If any parts are damaged or missing, spare
parts can be ordered using the Assembly Kit 6495MM (1 SET) for
T0638 or 6496MM (1 SET) for T0639.
ASSEMBLY AND INSTALLATION INSTRUCTIONS
T0638 / T0639
WWARNING: Turn off the main power at circuit breaker before installing fixture.
AVERTISSEMENT: Coupez la source d’alimentation principale au panneau central de disjoncteurs avant d’installer le luminaire.
NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS.
Hardware Package (included):
Mounting Plate Unit (A)
Mounting Screw (B)
Wire Connector (C)
Bolt Nut (D)
Rubber Pad (E)
Fixture
Outlet Box House Grounding Wire
Headless Screw Green Grounding Screw
Mounting Plate Unit (A) Mounting Screw (B)
Fixture Grounding Wire Wire Connector (C) Fixture Wire Backplate Rubber Pad (E) Bolt Nut (D)
Installation Steps
Max.60W Type A Bulb (not included)
Turn off the power at fuse or circuit box. 1. Unscrew the two bolt nuts (D)
remove the two rubber pads (E) and the mounting plate unit (A) from the backplate.
2. Attach the mounting plate unit (A) to the outlet box by using two mounting screws (B). Adjust the length of the preinstalled headless screws if necessary. Note: Make sure that two headless screws are lined up horizontally to make the fixture level.
220310 T
3. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows: · Connect the hot wire (usually black insulation) from the fixture to the black wire from the power source. · Connect the neutral wire (usually white insulation) from the fixture to the white wire from the power source. · Attach the fixture grounding wire (usually green with the insulation or bare wire) to the mounting plate unit (A) with green grounding screw. Then, depending on local code, connect it to the house grounding wire with the wire connector (C). Carefully put all of the wires back into the outlet box.
4. Install the bulb (not included). See relamping label at socket area or packaging for maximum wattage allowed.
5. Attach the backplate of the fixture to the mounting plate unit (A) by aligning and inserting the two headless screws into set holes on backplate, then secure it with two rubber pads (E) and two bolt nuts (D). Note: With silicone caulking compound, caulk completely around where the backplate meets with the wall surface to prevent water from seeping into the outlet box.
Turn on the power at fuse or circuit box.
The following parts are available for re-order if damaged or missing.
Spare Parts List:
Assembly Kit 6495MM (1 SET) for T0638 6496MM (1 SET) for T0639
Mounting Plate Unit (A)
Mounting Screw (B) Wire Connector (C)
Bolt Nut (D) Rubber Pad (E)
A B
A: 6-1/4″ B: 6-1/2″ C: 7-1/4″
C
220310