T0669 Outdoor Motion Sensor Wall Light
Product Information: Assembly and Installation Instructions for
T0669/T0670
The T0669/T0670 is an energy-saving fixture that comes with a
hardware package that includes a cross bar unit, mounting screws,
wire connector, bolt nut, rubber pad, backplate, outlet box, house
ground wire, socket shade, socket ring, and a maximum 60W Type A
bulb (not included). The fixture requires a 120V AC, 60 Hz power
source and is compatible with most LED dimmable bulbs. It features
a dim-to-full brightness option and manual override mode for
convenient use. The product also comes with a sensor lens and
adjustable knobs for time, low level brightness, and sensitivity
control.
Product Usage Instructions:
- Read all instructions carefully before installation and
operation. - If you are not familiar with state and local electrical codes,
it is recommended that you consult with a qualified
electrician. - Before installation, shut off power at the main fuse or circuit
breaker box. Be aware that simply turning off the wall switch is
not sufficient to prevent an electrical shock. - Attach the cross bar unit (A) to the outlet box by using two
mounting screws (B). Adjust the length of the preinstalled fixture
mounting screws if necessary. Note: Make sure that the fixture
mounting screws are lined up horizontally to make the fixture
level. - Attach the backplate of the fixture to the cross bar unit (A)
by inserting fixture mounting screws into set holes on the
backplate, then secure it with two rubber pads (E) and two bolt
nuts (D). Note: With silicone caulking compound, caulk completely
around where the backplate meets with the wall surface to prevent
water from seeping into the outlet box. - Attach the shade to the socket, then secure it with the socket
ring. - Install the bulb (not included). Check relamping label at
socket area or packaging for maximum wattage allowed. - Adjust time, low level brightness, and sensitivity control by
using the adjustable knobs and slide switch on the sensor
lens. - For general safety and to avoid any possible damage to the
sensor, be sure the power is switched off before replacing the
bulb.
Following these instructions will help ensure safe and proper
use of the T0669/T0670 fixture.
ASSEMBLY AND INSTALLATION
T0669 / T0670
INSTRUCTIONS
WWARNING: Turn off the main power at circuit breaker before installing fixture.
AVERTISSEMENT: Coupez la source d’alimentation principale au panneau
central de disjoncteurs avant d’installer le luminaire.
NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements. 2. READ AND SAVE THESE INSTRUCTIONS.
Important to Know
1. Read all instructions carefully before installation and operation.
2. If you are not familiar with state and local electrical codes, it is recommended that you consult with a qualified electrician.
3. Before installation, shut off power at the main fuse or circuit breaker box. Be aware that simply turning off the wall switch is not sufficient to prevent an electrical shock.
4. This fixture requires a 120V AC, 60 Hz power source. 5. Do not attempt to take the lantern apart; there are no
serviceable parts inside. 6. To avoid sensor damage by lightning or electrical surge,
make sure the ground wire is securely connected. 7. For general safety and to avoid any possible damage to
the sensor, be sure the power is switched “off” before replacing the bulb. 8. Compatible with most LED dimmable bulbs.
Maximum Wattage: 60W Bulb Work Temperature: – 22°F~104°F
Features
1. Energy saving fixture. 2. Use dim-to-full brightness where dim-illumination
is preferred, such as your front entrance. Use off-to-full brightness where off/on illumination is preferred, such as your backyard. 3. When in manual override mode, use wall switch to keep the light ON till dawn.
Hardware Package (included)
Cross Bar Unit (A)
Mounting Screw (B)
Wire Connector (C)
Bolt Nut (D) Rubber Pad (E)
Backplate
Outlet Box House Ground Wire Wire Connector (C)
Cross Bar Unit (A) Fixture Mounting Screw
Green Ground Screw Mounting Screw (B) Fixture Ground Wire Fixture Wire
Rubber Pad (E) Bolt Nut (D)
Socket Shade
Socket Ring
Max.60W Type A Bulb (not included)
Page 1 / 5
220524
Installation Steps
Turn off the power at fuse or circuit box
1. Attach the cross bar unit (A) to the outlet box by using two mounting screws (B). Adjust the length of the preinstalled fixture mounting screws if necessary. Note: Make sure that the fixture mounting screws are lined up horizontally to make the fixture level.
2. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows: · Connect the hot wire (usually black insulation) from the fixture to the black wire from the power source. · Connect the neutral wire (usually white insulation) from the fixture to the white wire from the power source. · Attach the fixture ground wire (usually green insulation or bare wire) to the cross bar unit (A) with the green ground screw. Then, depending on local code, then connect it to the house ground wire with the wire connector (C). Carefully put all of the wires back into the outlet box.
3. Attach the backplate of the fixture to the cross bar unit (A) by inserting fixture mounting screws into set holes on the backplate, then secure it with two rubber pads (E) and two bolt nuts (D). Note: With silicone caulking compound, caulk completely around where the backplate meets with the wall surface to prevent water from seeping into the outlet box.
4. Attach the shade to the socket, then secure it with the socket ring.
5. Install the bulb (not included). Check relamping label at socket area or packaging for maximum wattage allowed.
Turn on the power at fuse or circuit box.
The Position of Control Panel
Sensor Lens
View Fig.A
Sensor Lens
Fig.1
Fig.2
Fig.3
“Time” Knob “Low Level” Knob “Sens” Knob
Time Low Level Sens
Test 3H 6H 0
Slide Switch
Step 1: Rotate the sensor lens from left side to right side to show the adjustable knobs and slide switch. (See Fig.1)
Step 2: Adjust time low level brightness and sensitivity by knobs and choose the mode you want by slide switch. (See Fig.2 and Fig.A).
Step 3: Restore the sensor lens to original position. (See Fig.3)
Fig.A
Page 2 / 5
220524
Function and Operation
MODES OF OPERATION
Choose a mode by sliding the switch on the back of the sensor. When power is first applied, the light will turn on immediately. Wait for 30 seconds to allow the sensor to warm up.
1. TEST MODE (daytime and nighttime operation) The light will turn to low-level brightness (0%~50% brightness). The light will turn to high-level brightness (100% brightness) when motion is detected, and stay on as long as the motion is continuing. The light will revert to low-level brightness about 5 seconds after motion is no longer detected.
2. 3H MODE (nighttime operation only) At dusk, the light will turn to high-level brightness (100% brightness). The light will turn to low-level brightness (0% ~50% brightness) automatically after 3 hours. The light will turn to high-level brightness (100% brightness) when motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light will remain on for the predetermined time you set (5~180 seconds), and then revert to low-level brightness you set. Light will turn off automatically at dawn, and return to 3 H mode at dusk.
3. 6H MODE (nighttime operation only) At dusk, the light will turn to high-level brightness (100% brightness). The light will turn to low-level brightness (0% ~50% brightness) automatically after 6 hours. The light will turn to high-level brightness (100% brightness) when motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light will remain on for the predetermined time you set (5~180 seconds), and then revert to low-level brightness you set. Light will turn off automatically at dawn, and return to 6 H mode at dusk.
4. 0 MODE (nighttime operation only) The light will turn to low level brightness (0%~50% brightness) at dusk. The light will turn to high-level brightness (100% brightness) when motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light will remain on for the predetermined time you set (5~180 seconds), and then revert to low level brightness you set. Light will turn off automatically at dawn, and return to 0 H mode at dusk.
5. Manual Override MODE (nighttime operation only; on at dusk, off at dawn) In 3, 6 or 0 mode, to shift to manual override mode, turn off the wall switch in 3 seconds and then turn it on again, the light will turn to high-level brightness at dusk, and turn off automatically at dawn. To return to the previous settings, turn off the wall switch in 3 seconds and then turn it on again. (See Fig.4 Fig.5) The lights will turn off automatically at dawn.
Fig.4
Manual Override Operation Diagram
“3H Mode” “6H Mode” “0 Mode”
Turn wall switch OFF-ON in 3 Seconds
Turn wall switch OFF-ON in 3 Seconds again
Manual Override Mode
Fig.5
On the back of the sensor
Time Low Level Sens
Test 3H 6H 0
CUSTOMIZATION OPTIONS:
Shut-off Delay
The Shut-off delay is the length of time the light will stay at high-level brightness after motion has ceased to be detected. This Shut-off delay can be set when operation is in 3, 6 or 0 Mode by using the “TIME” knob located on the left side of the panel at the back of the sensor lens (See Fig.5). To increase the shut-off delay, turn the knob clockwise. To decrease shut off delay, turn the knob counterclockwise. The delay may be adjusted from a minimum of 5 seconds to a maximum of 3 minutes. The light will stay on as long as motion is detected continuously and will automatically turn to low-level brightness when no more motion is detected after the delay time has passed.
Sensitivity of Motion Sensor The sensitivity of the motion sensor can be adjusted by using the “Sens” knob located on the right side of the panel at the back of sensor lens (See Fig.5). To increase sensitivity, turn the knob clockwise. To decrease sensitivity, turn the knob counterclockwise. The sensitivity may be adjusted from a minimum of 5 feet to a maximum of 40 feet.
Page 3 / 5
220524
NOTE:
1. The sensitivity of the motion sensor will increase as the environmental temperature gets cooler. For best performance, gently clean the lens with a soft cloth every 1 or 2 months to assure maximum sensitivity.
2. For best performance, install fixture at least 6 feet above the ground. At such a height, the fixture will provide a detection distance of up to 40 feet at 77 degrees fahrenheit. (See Fig.6)
3. The sensor detects across a detection range of 180 degrees (See Fig.7)
4. The sensor will be more sensitive to motion across its detection path than motion directly towards it. (See Fig.8)
5. To reduce possible nuisances, do not mount the fixture near a heat source like an air conditioner, vent or furnace exhaust, or in a direction facing any reflecting object or
Where you install your lantern is important: Be sure the light is mounted straight on the wall; otherwise, the detection distance may be limited.
10`
6` 5`
Fig. 6
40`
Fig. 7
180°
Fig.8
Motion
Motion
Troubleshooting
—The light does not come on at all: 1. Make sure the wall switch and circuit breaker are on. 2. Make sure the wiring is correct. 3. Make sure the bulb is not burned out. 4. Cover the sensor with your palm to verify that the
ambient light level is not too high.
Sensor Least sensitivity
—-In Test Mode, the light stays on full brightness after 5 seconds: 1. If during daytime, make sure the slide switch is at the TEST position. 2. If motion continues to be detected.
Most sensitivity
—In 3H or 6H Mode, the light is still on full brightness, even though it has been 3 hours or 6 hours after dusk, respectively:
1. Make sure no motion could be picked up by the sensor. 2. Make sure that mode entry is not in manual override.
—After performing 3H or 6H Mode, the light stays on full brightness after 3 minutes: 1. Make sure there is no movement that could be picked up by the sensor. 2. Adjust the time knob counterclockwise to reduce the delay shut-off time.
—-In 3H or 6H Mode, the light turns off completely, instead of low level brightness, after 3 minutes: 1. Make sure the bulb you installed is a medium base bulb or LED dimmable bulb. 2. Make sure the bulb is in working condition. 3. Make sure the low level is not at the 0% position.
— The light blinks: 1. Make sure the light is not mounted near a barbecue, air conditioner or other heat source. 2. Adjust the sensitivity knob counterclockwise to avoid unnecessary triggering like a passing car or
reflecting objects. 3. Make sure the bulb is medium base bulb or LED dimmable bulb.
Page 4 / 5
220524
The following parts are available for re-order if damaged or missing.
Spare Parts List:
Assembly Kit 6525MM (1 SET)
Cross Bar Unit (A)
Mounting Screw (B) Wire Connector (C) Bolt Nut (D) Rubber Pad (E)
A B
T0669
T0670
A: 9-1/2″ A: 10-1/2″
B: 10″
B: 12″
C: 11-3/4″ C: 14″
C
Page 5 / 5
220524