Amber Connect Apt200 Multifunctional Gps Tracker User Guide

APT200 Multifunctional GPS Tracker

Product Information:

  • MODULE Name: APT200 GSM/GPRS/GNSS/BLUETOOTH
  • GNSS: GPS, GLONASS, GALILEO, BEIDOU, SBAS, QZSS, DGPS,
    AGPS
    • GNSS Receiver: 33 channel
    • Tracking sensitivity: -165 dBM
    • Accuracy: < 3 m
    • Hot start: < 1 s
    • Warm start: < 25 s
    • Cold start: < 35 s
  • Cellular Technology: 2G bands
    • Data transfer: GPRS Multi-Slot Class 12 (up to 240
      kbps)
    • Data support: SMS (text/data)
  • Power:
    • Input voltage range: 10-30 V DC with overvoltage
      protection
    • Back-up battery: 170 mAh Li-Ion battery 3.7 V (0.63
      Wh)
    • Power consumption:
      • Ultra Deep Sleep: < 2.5 mA (at 12V)
      • Deep Sleep: < 5 mA (at 12V)
      • Online Sleep: < 5.5 mA (at 12V)
      • GPS Sleep: < 18.5 mA (at 12V)
      • Nominal: < 34 mA (at 12V with no load)
  • BLUETOOTH:
    • Specification: 4.0 + LE
    • Supported peripherals: Temperature and Humidity sensor,
      Headset, OBDII dongle, Inateck Barcode Scanner, Universal BLE
      sensors support
  • INTERFACE:
    • Digital Inputs: 3
    • Negative Inputs: 1 (Digital Input 2)
    • Impulse Inputs: 2 (Digital Input 1, Digital Input
      2)
    • Digital Outputs: 3
    • Analog Inputs: 2
    • CAN Adapter inputs: 1
    • 1-Wire: GNSS antenna
    • GSM antenna: Internal High Gain
    • USB: 2.0 Micro-USB
    • LED indication: 2 status LED lights
    • SIM: Micro-SIM + eSIM
    • Memory: 128MB internal flash memory
  • PHYSICAL SPECIFICATION:
    • Dimensions: 65 x 56,6 x 20,6 mm (L x W x H)
    • Weight: 55 g
    • Operating Environment:
      • Operating temperature (without battery): -30°C to
        +75°C
      • Storage temperature (without battery): -40°C to
        +85°C
      • Operating humidity: 5% to 95% non-condensing
      • Ingress Protection Rating: IP41
      • Battery discharge temperature: -20°C to +60°C
  • FEATURES:
    • Sensors: Accelerometer
    • Scenarios: Green Driving, Over Speeding detection,
      Jamming detection, GNSS Fuel Counter, DOUT Control Via Call,
      Excessive Idling detection, Immobilizer, iButton Read Notification,
      Unplug detection, Towing detection, Crash detection, Auto Geofence,
      Manual Geo fence, Trip
    • Sleep modes: GPS Sleep, Online Deep Sleep, Deep Sleep,
      Ultra Deep Sleep
    • SMS: Configuration, Events, DOUT control, Debug
    • GPRS commands: Configuration, DOUT control, Debug
    • Time Synchronization: GPS, NITZ, NTP
    • Fuel monitoring: LLS (Analog), LV-CAN200, ALL-CAN300,
      OBDII dongle, CANCONTROL
  • ACCESSORIES:
    • Bluetooth and analog fuel sensor
    • RFID reader
    • Temperature sensor: Bluetooth fuel sensor, Analog fuel
      sensor, Wired temperature sensor
  • Electrical characteristics:
    • Supply Voltage (Recommended Operating Conditions):
      +10V
    • Drain current (Digital Output OFF): 47 Ω
    • Drain current (Digital Output ON, Recommended Operating
      Conditions):
      38.45 Ω
    • Static Drain-Source resistance (Digital Output ON): 150
      Ω
    • Input resistance (DIN1): 0 Ω
    • Input resistance (DIN2): 47 Ω
    • Input resistance (DIN3): 38.45 Ω
    • Input voltage (Recommended Operating Conditions):
      0V
    • Input Voltage threshold (DIN1): Measurement error on
      12V, Range 1
    • Input Voltage threshold (DIN2): Measurement error on
      12V, Range 1
    • Input Voltage threshold (DIN3): Measurement error on
      12V, Range 1
    • Input voltage (Recommended Operating Conditions), Range
      1:
      0V
    • Input resistance, Range 1: Measurement error on 12V,
      Range 1
    • Measurement error on 12V, Range 1: Additional error on
      12 V, Range 1
    • Additional error on 12 V, Range 1: Measurement error on
      30 V, Range 1
    • Measurement error on 30 V, Range 1: Additional error on
      30 V, Range 1
    • Input Voltage (Recommended Operating Conditions), Range
      2:
      0V
    • Input resistance, Range 2: N/A

Product Usage Instructions:

  • The APT200 GSM/GPRS/GNSS/BLUETOOTH module can be used for
    tracking objects or vehicles.
  • The GNSS receiver can track GPS, GLONASS, GALILEO, BEIDOU,
    SBAS, QZSS, DGPS, and AGPS satellites with high accuracy.
  • The module supports 2G bands for data transfer and SMS
    support.
  • The input voltage range is between 10-30V DC with overvoltage
    protection and has a back-up battery of 170 mAh Li-Ion battery 3.7V
    (0.63 Wh).
  • The module has different sleep modes, such as GPS Sleep, Online
    Deep Sleep, Deep Sleep, and Ultra Deep Sleep, to save power.
  • The APT200 GSM/GPRS/GNSS/BLUETOOTH module has several sensors,
    including an accelerometer, for Green Driving, Over Speeding
    detection, Jamming detection, GNSS Fuel Counter, DOUT Control Via
    Call, Excessive Idling detection, Immobilizer, iButton Read
    Notification, Unplug detection, Towing detection, Crash detection,
    Auto Geofence, Manual Geo fence, and Trip scenarios.
  • The module can be configured using SMS and GPRS commands for
    events, DOUT control, and debugging.
  • The time synchronization can be done using GPS, NITZ, or
    NTP.
  • Fuel monitoring is available using LLS (Analog), LV-CAN200,
    ALL-CAN300, OBDII dongle, CANCONTROL.

1. Characteristic
MODULE
Name Technology
GNSS
GNSS Receiver Tracking sensitivity Accuracy Hot start Warm start Cold start
Cellular
Technology 2G bands Data transfer Data support
POWER
Input voltage range Back-up battery
Power consumption
BLUETOOTH
Specification
Supported peripherals

APT200 GSM/GPRS/GNSS/BLUETOOTH
GPS, GLONASS, GALILEO, BEIDOU, SBAS, QZSS, DGPS, AGPS 33 channel -165 dBM < 3 m < 1 s < 25 s < 35 s
GSM Quad-band 850 / 900 / 1800 / 1900 MHz GPRS Multi-Slot Class 12 (up to 240 kbps), GPRS Mobile Station Class B SMS (text/data)
10-30 V DC with overvoltage protection 170 mAh Li-Ion battery 3.7 V (0.63 Wh) At 12V < 2.5 mA (Ultra Deep Sleep) At 12V < 5 mA (Deep Sleep) At 12V < 5.5 mA (Online Sleep) At 12V < 18.5 mA (GPS Sleep) At 12V < 34 mA (nominal with no load)
4.0 + LE Temperature and Humidity sensor, Headset, OBDII dongle, Inateck Barcode Scanner, Universal BLE sensors support

INTERFACE
Digital Inputs Negative Inputs 1

3 1 (Digital Input 2)

Impulse Inputs Digital Outputs Analog Inputs CAN Adapter inputs 1-Wire GNSS antenna GSM antenna USB LED indication SIM Memory

2 (Digital Input 1, Digital Input 2) 3 2 1 1 Internal High Gain Internal High Gain 2.0 Micro-USB 2 status LED lights Micro-SIM + eSIM 128MB internal flash memory

PHYSICAL SPECIFICATION

Dimensions

65 x 56,6 x 20,6 mm (L x W x H)

Weight

55 g

OPERATING ENVIRONMENT

Operating temperature (without battery)

-40 °C to +85 °C

Storage temperature (without
battery)

-40 °C to +85 °C

Operating humidity

5% to 95% non-condensing

Ingress Protection Rating IP41

Battery charge temperature 0 °C to +45 °C

Battery discharge temperature

-20 °C to +60 °C

-20 °C to +45 °C for 1 month Battery storage temperature
-20 °C to +35 °C for 6 months

FEATURES
Sensors
Scenarios
Sleep modes SMS GPRS commands Time Synchronization Fuel monitoring

Accelerometer
Green Driving, Over Speeding detection, Jamming detection, GNSS Fuel Counter, DOUT Control Via Call, Excessive Idling detection, Immobilizer, iButton Read Notification, Unplug detection, Towing detection, Crash detection, Auto Geofence, Manual Geo fence, Trip
GPS Sleep, Online Deep Sleep, Deep Sleep, Ultra Deep Sleep
Configuration, Events, DOUT control, Debug
Configuration, DOUT control, Debug GPS, NITZ, NTP LLS (Analog), LV-CAN200, ALL-CAN300, OBDII dongle, CANCONTROL

ACCESSORIES
Bluetooth and analog fuel sensor RFID reader Temperature sensor
Bluetooth fuel sensor

Analog fuel sensor

RFID reader

Wired temperature sensor

2. Electrical characteristics

CHARACTERISTIC DESCRIPTION

MIN.

SUPPLY VOLTAGE

Supply Voltage (Recommended Operating Conditions)

+10

DIGITAL OUTPUT (OPEN DRAINGRADE)
Drain current (Digital Output OFF)
Drain current (Digital Output ON, Recommended Operating Conditions)
Static Drain-Source resistance (Digital Output ON)

DIGITAL INPUT
Input resistance (DIN1) Input resistance (DIN2) Input resistance (DIN3) Input voltage (Recommended Operating Conditions) Input Voltage threshold (DIN1) Input Voltage threshold (DIN2) Input Voltage threshold (DIN3)

47 38.45 150
0

ANALOG INPUT

Input voltage (Recommended Operating Conditions), Range 1

0

Input resistance, Range 1

Measurement error on 12V, Range 1

Additional error on 12 V, Range 1

Measurement error on 30 V, Range 1

Additional error on 30 V, Range 1

Input Voltage (Recommended Operating Conditions), Range 2

0

Input resistance, Range 2

Measurement error on 12 V, Range 2

Additional error on 12 V, Range 2

Measurement error on 30 V, Range 2

Additional error on 30 V, Range 2

OUTPUT SUPPLY VOLTAGE 1-WIRE

Supply voltage

+4.5

Output inner resistance

Output current (Uout > 3.0 V)

Short circuit current (Uout = 0)

VALUE

TYP.

MAX.

+30

120

0.1

0.5

400

600

Supply voltage 7.5 2.5 2.5

38.45 0.9 108 0.33 88
150 0.9 108 0.33 88
7 30 75

+10 +30 +4.7

UNIT
V
µA A
m
k k k V V V V
V k % mV % mV V k % mV % mV
V mA mA

3. Pinout
PIN NUMBER
1 2
3
4 5 6 7
8
9 10 11 12

PIN NAME VCC (10-30) V DC (+) DOUT 3
DIN 3 / AIN 2
DIN 2 -N / AIN 1 DIN 1 INPUT 6 GND (-)
DOUT 1
DOUT 2 1WIRE POWER 1WIRE DATA INPUT 5

DESCRIPTION
Power supply (+10-30 V DC). Digital output, channel 3, Open collector output. Max 0,5 A DC.. Analog input, channel 2. Input range: 0-30 V DC / Digital input, channel 3. Digital input, channel 2, Negative input, Analog input, channel 1, Input range: 0- 30 V DC. Digital input, channel 1. TX EXT (LVCAN ­ TX). Ground pin. (10-30) V DC ()
Digital output, channel 1. Open collector output. Max. 0,5 A DC
Digital output, channel 2. Open collector output. Max. 0,5 A DC
+3,8 V output for 1­Wire devices. Data for 1­Wire devices. RX EXT (LVCAN – RX).

Wiring Scheme
Accessories Connection Possibilities
3 IN ports/pin o 1 Digital o 2 Digital or Analog
3 OUT ports/pins o 3 Digital (for future use)
1 One-wire connection
Installation team must follow the below Accessory connection for efficient working. If installation has to be done with different patterns then please contact your immediate tech support for the possibilities. You can configure these accessories settings in our amber connect fleet management platform. Fleet Portal > Settings > Vehicle > Safety > Device Input Configuration [This setting available Only to specific device models that supports the accessories] Warning: These settings should exactly match with the actual accessories connected to the device ports during the installation. If you make any changes on this will result in data reception from accessories to the device. So Kindly make sure you are changing this with proper understanding of which accessory connected to which wire during the installation.

4. Mounting Recommendations
1) Connecting wires
a) Wires should be connected while the module is not plugged in. b) Wires should be fastened to stable wires or other non-moving parts. Any heat
emitting and/or moving objects should be kept away from the wires. c) There should be no exposed wires. If factory isolation was removed while
connecting the wires, the isolation material should be applied. d) If the wires are placed in the exterior or in places where they can be damaged or
exposed to heat, humidity, dirt, etc., additional isolation should be applied and the wires should not be loose. e) Wires cannot be connected to the board computers or control units.
2) Connecting power source
a) Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the car model, this may happen in 5 to 30 minutes period.
b) When the module is connected, measure the voltage again to make sure it did not decrease.
c) It is recommended to connect to the main power cable in the fuse box. d) 3 A, 125 V external fuse shall be used.
3) Connecting ignition wire
a) Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
b) Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
c) Check if power is still available when you turn off any of vehicles devices. d) Ignition is connected to the ignition relay output. As alternative, any other relay,
which has power output when ignition is on, may be chosen.
4) Connecting ground wire
a) Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
b) If the wire is fixed with the bolt, the loop must be connected to the end of the wire. c) For better contact scrub paint from the spot where loop is going to be connected.

5. LED Indications
BEHAVIOUR
Permanently switched on Blinking every second
Off
Blinking fast constantly

MEANING
GNSS signal is not received Normal mode, GNSS is working GNSS is turned off because: Device is not working or Device is in Sleep mode Device firmware is being flashed

BEHAVIOUR
Blinking every second Blinking every two seconds

Normal mode Sleep mode

MEANING

Blinking fast for a short time

Modem activity

Off

Device is not working or Device is in Boot mode

6. Safety information

This message contains information on how to operate safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!

The device uses SELV limited power source. The nominal voltage is+12 V DC. The allowed voltage range is +10…+30 V DC.

To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of device operation.

When connecting the 2×6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.
Before unmounting the device from the vehicle, the 2×6 connector must be disconnected.
The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 62368-1 standard. The device is not designed as a navigational device for boats.

Do not disassemble the device. If the device is damaged, the power supply cables are not isolated or the isolation is damaged, DO NOT touch the device before unplugging the power supply.
All wireless data transferring devices produce interference that may affect other devices which are placed nearby.
The device must be connected only by qualified personnel.

The device must be firmly fastened in a predefined location.

The programming must be performed using a PC with autonomic power supply.

Installation and/or handling during a lightning storm is prohibited.
The device is susceptible to water and humidity.
Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. Battery should not be disposed of with general household waste. Bring damaged or wornout batteries to your local recycling center or dispose them to battery recycle bin found in stores.

7. Certification and Approvals
ANATEL RoHS
This sign on the package means that it is necessary to read the User Manual before your start using the device.
This sign on the package means that all used electronic and electric equipment should not be mixed with general household waste.
Hereby, we declare under our sole responsibility that the above described product is in conformity with the relevant Community harmonization: European Directive 2014/53/EU (RED).

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals