FCA23 Sollatek Temp Control
Product Information
The Sollatek FCA23 is a temperature control kit manufactured by
True Manufacturing Co., Inc. It is available in two models:
P#848325 (Universal) and P#848326 (Wine/Chocolate). The temperature
control kit is compatible with all voltages.
Before You Begin
Before starting the installation process, please ensure the
following:
- Determine the airflow direction for proper installation.
- Determine the voltage and label wires accordingly.
- If your unit has a 4-wire fan motor, refer to the instructions
provided for proper installation.
Probe Installation
There are two types of probe installations:
- Mechanical Control Probe Installation
- Electronic Control Probe Installation
Relay Installation
Follow the steps below for relay installation:
- Connect the provided wires to the provided relay.
- If your appliance has an existing relay, replace it with the
provided relay. - If your appliance has an electrical box, add the provided relay
following the instructions provided. - If your appliance does not have an electrical box, add the
provided relay following the instructions provided.
Troubleshooting
If you encounter any issues, refer to the troubleshooting
section for basic troubleshooting steps. Additionally, there are
Control Indicator Light Codes and a Temperature-to-Resistance Table
for reference.
Appendix
The appendix includes instructions for rewiring the 4-wire EBM
fan motor and control knob cover installation.
Product Usage Instructions
1. Before starting the installation, determine the airflow
direction and voltage of your unit. Label the wires
accordingly.
2. If your unit has a 4-wire fan motor, follow the provided
instructions for proper installation.
3. Install the probe based on the type of control system you
have:
- For mechanical control, follow the Mechanical Control Probe
Installation instructions. - For electronic control, follow the Electronic Control Probe
Installation instructions.
4. Proceed with relay installation:
- Connect the provided wires to the provided relay.
- If your appliance already has a relay, replace it with the
provided relay. - If your appliance has an electrical box, follow the
instructions for adding the provided relay. - If your appliance does not have an electrical box, follow the
instructions for adding the provided relay.
5. If you encounter any issues, refer to the troubleshooting
section for basic troubleshooting steps. Use the Control Indicator
Light Codes Table and Temperature-to-Resistance Table for further
assistance.
6. For additional information or support, please contact True
Manufacturing Co., Inc. Technical Service team using the provided
contact information.
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
845565
STOP STOP! All work detailed in these instructions must be done by a qualified technician. STOP
Subject: Sollatek FCA23 Installation Date: June 23, 2023 Models / Parts Affected: Electronic Temperature Control Kits P#848325 (Universal) & P#848326 (Wine/
Chocolate) Voltages: All Voltages
Contents
Overview Kit Components…………………………………………………………………………………..2 Required Tools……………………………………………………………………………………..2 Control Specifications ………………………………………………………………………..2 Control Operation……………………………………………………………………………….3 Hazardous Food Warning Label……………………………………………………….3
Before You Begin (Mechanical Control) Determine Airflow Direction …………………………………………………………….4 Determine Voltage & Label Wires…………………………………………………….4 4-Wire Fan Motors ………………………………………………………………………………4
Probe Installation Mechanical Control Probe Installation ……………………………………………5 Electronic Control Probe Installation ………………………………………………5
Temperature Control Installation 1. Connect the Probes to the Control………………………………………………6 2a. Direct Replacement………………………………………………………………………6 2b. Replace a Mechanical Control…………………………………………………….6 2c. Replace a Sollatek FCA22 …………………………………………………………….7 2d. Replace a TEC22 ……………………………………………………………………………7
Relay Installation 1. Connect the Provided Wires to the Provided Relay………………….8 2a. Replace the Existing Relay…………………………………………………………..8 2b. Add the Provided Relay (Appliances with an Electrical Box) ..9 2c. Add the Provided Relay (Appliances without an Electrical Box) ……………………………………………………………………………………………………10
Troubleshooting Basic Troubleshooting………………………………………………………………………..13 Control Indicator Light Codes Table ………………………………………………..13 Temperature-to-Resistance Table…………………………………………………….14
Appendix Rewiring the 4-Wire EBM Fan Motor ……………………………………………….15 Control Knob Cover Installation ……………………………………………………….16
Questions or Concerns
For more information, please contact our Technical Service team. See contact information below.
Contact Us
North America USA, Canada & Caribbean
Warranty Phone: +1 855 878 9277 Warranty Fax: +1 636 980 8510 Warranty Email: [email protected] Technical Phone: +1 855 372 1368 Technical Email: [email protected] 7:00am-6:00pm CST Monday-Friday; 8:00am-12:00pm Saturday
European Union & Commonwealth of Independent States
Phone: +49 (0) 7622 6883 0 [email protected] 8:00am-5:00pm M-F
UK, Ireland, Middle East, Africa & India
Phone: +44 (0) 800 783 2049 [email protected] 8:30am-5:00pm M-F
Latin America
Phone: +52 555 804 6343/44 [email protected] 9:00am-5:30pm M-F
Mexico
Phone: +52 555 804 6343/44 [email protected] 9:00am-5:30pm M-F
Australia
Phone: +61 2 9618 9999 [email protected] 8:30am-5:00pm M-F
Overview
The Sollatek FCA 23 holds an average product temperatures of 32-40°F (0-4.4°C) for universal applications and 39-71°F (3.9-21.7°C) for wine/ chocolate applications. The electronic temperature control requires a neutral line to complete the circuit.
NOTE: Always install the provided relay. Some applications may have an existing relay; in these cases replace the existing relay.
WARNING! Electrical shock or burn hazard. Powering off an electronic control does not remove power from all components. Unplug the unit or turn off the power supply before proceeding.
WARNING! Sharp edges. Take care when installing, cleaning, servicing, and maintaining the equipment.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 1 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
Kit Components
NOTE: Required components and quantities vary by model.
Universal Control Kit Components · (1) Electronic Temperature Control · (1) Black Probe (thermostat) · (1) White Probe (defrost) · (1) White/Blue Wire with 1/4″ Blue Spade Connector · (1) Black Wire (bare) · (3) 1/4″ Spade Connectors · (2) 2-Way Lever Connectors · (1) 3-Way Lever Connector · (1) 5-Way Lever Connector · (6) Small Cable Ties · (2) 1/4″ P-Clips · (4) 3/16″ Black P-Clips · (6) 8-18 x 1/2″ Hex Head Screws · (2) 6-20 x 5/16″ Phillips Hex Head Screws · (2) M4 x 10 Pan Head Phillips Screws
Universal Control Relay Kit Components · (1) Temperature Control Relay · (1) Black Wire with 1/4″ Blue Spade Connector · (1) Brown/Red Wire with 1/4″ Blue Spade Connector · (1) Brown Wire with 3/16″ Red Spade Connector · (1) White Wire with 3/16″ Red Spade Connector · (4) 2-Way Lever Connectors · (1) 3-Way Lever Connector · (2) 5-Way Lever Connectors · (2) M4 x 12 mm Hex Head Screws
Wine/Chocolate Control Kit Components · (1) Electronic Temperature Control · (1) Black Probe (thermostat) · (1) White Probe (defrost) · (1) White/Blue Wire with 1/4″ Blue Spade Connector · (1) Black Wire (bare) · (3) 1/4″ Spade Connectors · (2) 2-Way Lever Connectors · (1) 3-Way Lever Connector · (1) 5-Way Lever Connector · (6) Small Cable Ties · (2) 1/4″ P-Clips · (4) 3/16″ Black P-Clips · (6) 8-18 x 1/2″ Hex Head Screws · (2) 6-20 x 5/16″ Phillips Hex Head Screws · (1) Hazardous Food Warning Label · (2) M4 x 10 Pan Head Phillips Screws
Wine/Chocolate Control Relay Kit Components · (1) Temperature Control Relay · (1) Black Wire with 1/4″ Blue Spade Connector · (1) Brown/Red Wire with 1/4″ Blue Spade Connector · (1) Brown Wire with 3/16″ Red Spade Connector · (1) White Wire with 3/16″ Red Spade Connector · (4) 2-Way Lever Connectors · (1) 3-Way Lever Connector · (2) 5-Way Lever Connectors · (2) M4 x 12 mm Hex Head Screws
845565
Required Tools
Required tools include (but may not be limited to) the following: · Gloves · Wire Cutters/Crimpers/Strippers · Phillips Screwdriver or Bit Driver · Flat Blade Screwdriver · 1/4″ Hex Head Driver · Needle Nose Pliers NOTE: Required equipment varies by model
Control Specifications
2-3/16″ (55.6 mm)
· Volt Meter · Adjustable Wrench · Tape · Marking Utensil · Drill
Table 1. Electrical Specifications
Voltage
75-240 V AC
Frequency
50/60 Hz
Fig. 1. The mounting holes measure 2-3/16″ (55.6 mm) center-to-center. The replacement control mounts in the same location as the existing control.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 2 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
Control Operation
The electronic temperature control… · Cycles the compressor on and off based on the return air temperature. See table 2 and table 3. · Automatically defrosts every four (4) hours of compressor run time. · Initiates an additional defrost if the evaporator coil temperature drops to 9°F (12.8°C). · Defrosts between 4 min minimum and 40 min maximum, or until the evaporator coil measures 38°F (3.4°C).
845565
Table 2. Universal Control Setting Temperature Chart
Control Setting
Cut-In °F (°C)
Cut-Out °F (°C)
Avg. Product Temperature
°F (°C)
#1
43 (6.1)
37 (2.7)
40 (4.4)
#2
42 (5.5)
36 (2.2)
39 (3.9)
#3
41 (5.0)
35 (1.6)
38 (3.3)
#4
40 (4.4)
34 (1.1)
37 (2.8)
#5
39 (3.8)
33 (0.5)
36 (2.2)
#6
38 (3.3)
32 (0.0)
35 (1.7)
#7
37 (2.7)
31 (-0.6)
34 (1.1)
#8
36 (2.2)
30 (-1.2)
33 (0.5)
#9
35 (1.6)
29 (-1.7)
32 (0.0)
Table 3. Wine/Chocolate Control Setting Temperature Chart
Control Setting
Cut-In °F (°C)
Cut-Out °F (°C)
Avg. Product Temperature
°F (°C)
#1
74 (23.3)
68 (20.0)
71 (21.7)
#2
70 (21.1)
64 (17.8)
67 (19.5)
#3
66 (18.9)
60 (15.6)
63 (17.3)
#4
62 (16.6)
56 (13.3)
59 (15.0)
#5
58 (14.4)
52 (11.1)
55 (12.8)
#6
54 (12.2)
48 (8.9)
51 (10.6)
#7
50 (10.0)
44 (6.7)
47 (8.4)
#8
46 (7.7)
40 (4.7)
43 (6.2)
#9
42 (5.5)
36 (2.2)
39 (3.9)
Hazardous Food Warning Label (Wine/Chocolate Kit Only)
If adjusting the set point to 41°F (5°C) or greater, place the provided hazardous food warning label below the serial label inside the cabinet as shown in fig. 1. This label notifies users the cabinet has been set to maintain a temperature above outside NSF perishable food storage guidelines.
Fig. 2. Hazardous food warning label intended location.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 3 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
845565
Before You Begin (Mechanical Controls)
If converting a mechanical control to an electronic control, see the following information. If replacing an electronic control, procede to “Temperature Control Installation” (pg. 6).
Determine Airflow Direction
Determine the airflow direction through the evaporator coil. See figs. 1 and 2. Airflow direction dictates probe placement. the black (thermostat) probe will be placed in the return air stream.
Probe Side
Probe Side
Fig. 1. The fan motor pushes air through the coil. Place probe on indicated side. Items not to scale.
Fig. 2. The fan motor pulls air through the coil. Place probe on indicated side. Items not to scale.
Determine Voltage Wire & Label Wires
1. At the temperature control, with a volt meter, locate the following wires and mark them as directed below:
· Line in/Line; Label wire LINE. · Line out/Load; Label wire LOAD. 2. Remove the mechanical control.
4-Wire Fan Motors
TRUE T-Series or GDM ONLY Check the unit for a 4-wire evaporator fan motor or a sticker (see fig. 3) on the evaporator housing. If present, rewire the fan motor before proceeding. See “Rewiring the 4-Wire EBM Fan Motor” (pg. 15).
Fig. 3. Fan motor sticker will be on the evaporator housing.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 4 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
845565
Probe Installation
Mechanical Control Probe Installation
1. Unplug the unit or remove the power supply.
2. Remove the existing probes.
3. With the provided mounting hardware (see fig. 1) install the provided black (thermostat) probe in the return air stream (see pg. 4).
NOTE: Be sure the black probe does not contact a metal surface; otherwise, it will read surface temperature, instead of return air temperature.
4. On any airflow side of the evaporator coil, locate the horizontal and vertical centers. See fig. 2. Then, push the white (defrost) probe into the center.
NOTE: Insert the probe flush with the coil fins. Tuck the coil fins around the probe to help secure it. See fig. 3.
5. Run the probe wires to the temperature control installation location.
6. With the provided 3/16″ p-clips or cable ties, secure the probe wires to prevent contact with moving parts.
7. Proceed to “Temperature Control Installation” (pg. 6).
Fig. 1. Use a p-clip to secure the probe to the appliance or a cable tie to attach it to a bracket or wire.
Fig. 2. Install the white probe tip in the center of the evaporator coil’s airflow Fig. 3. Pinch the evaporator coil fins around the probe. side.
Electronic Control Probe Installation
1. Unplug the unit or remove the power supply. 2. Remove the existing probes. 3. Install the replacement probes in the original probe locations:
· Black (thermostat) in the return air stream (see pg. 4). · White (defrost) in the center of an airflow side of the coil
(see fig. 2) Run the probe wires to the temperature control installation location. 4. With the provided 3/16″ p-clips or cable ties, secure the probe
wires to prevent contact with moving parts. 5. Proceed to “Temperature Control Installation” (pg. 6).
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 5 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
Temperature Control Installation
1. Connect the Probes to the Control
Connect the probes to the replacement temperature control as follows (see fig. 2): · Black (thermostat) probe to PRB1 terminal · White (defrost) probe to PRB2 terminal
NOTE: Confirm probe connections before proceeding. Reversing the wires will cause incorrect operation.
845565
2a. Direct Replacement
1. Unplug the appliance or remove the power supply.
2. Replace the control components and probes like-for-like.
3. Install the relay. See “Relay Installation” (pg. 8).
Fig. 2. Probe terminal locations.
2b. Replace a Mechanical Control
1. With a provided lever connector, splice in a neutral wire from any component (such as the evaporator fan motor or electrical box) to connect to the replacement control.
2. Connect the marked wires (from pg. 4) to the replacement temperature control as follows (see fig. 3):
· LINE wire to Live In terminal · LOAD wire to Comp terminal · Neutral wire to Neutral terminal NOTE: To cycle the evaporator fan motor on and off with the compressor, connect the wire powering the evaporator fan motor to Aux1. See fig. 3.
3. If Aux1 is unused, cover it with the 1/4″ female spade connector.
4. With the provided Phillips hex head screws, install the control in the appliance. See fig. 4.
NOTE: DO NOT overtighten the screws.
5. Align the flattened edge of the control knob’s slot with the temperature control’s shaft. Push the knob onto the shaft.
6. Fully turn the knob counterclockwise and mark #0.
7. Turn the knob clockwise until your mark aligns with #5 before powering the appliance.
NOTE: Powering the appliance when the control is set to #9 or #0 initiates test mode. To stop the test, remove power for five (5) min to reset the control. Then, set the control to #5 before reapplying power.
8. Install the relay. See “Relay Installation” (pg. 8).
Fig. 3. Replacement temperature control terminals.
Fig. 4. DO NOT overtighten the screws when installing the control.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 6 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
845565
2c. Replace a Sollatek FCA22
1. Label the existing temperature control’s remaining wire connections.
2. Remove the existing temperature control.
3. Connect the labeled wires to the replacement temperature control as follows (see fig. 5):
· Neutral wire to Neutral terminal · Live in wire to Live In terminal · Comp wire to Comp terminal · Aux wire to Aux1 terminal NOTE: If Aux1 is unused, cover it with the 1/4″ female spade connector.
4. With the provided Phillips hex head screws, install the control in the appliance. See fig. 4.
NOTE: DO NOT overtighten the screws.
5. Align the flattened edge of the control knob’s slot with the temperature control’s shaft. Push the knob onto the shaft.
6. Fully turn the knob counterclockwise and mark #0.
7. Turn the knob clockwise until your mark aligns with #5 before powering the appliance.
NOTE: Powering the appliance when the control is set to #9 or #0 initiates test mode. To stop the test, remove power for five (5) min to reset the control. Then, set the control to #5 before reapplying power.
8. Install the relay. See “Relay Installation” (pg. 8).
A
B
Fig. 5. Existing wiring configuration (A) and the replacement wiring configuration (B).
2d. Replace a TEC22
1. Label the existing temperature control’s remaining wire connections.
2. Remove the existing temperature control.
3. Connect the labeled wires to the replacement temperature control as follows (see fig. 6):
· N wire to Neutral terminal · L wire to Live In terminal · COMP wire to Comp terminal · FAN wire to Aux1 terminal NOTE: If Aux1 is unused, cover it with the 1/4″ female spade connector.
4. With the provided Phillips hex head screws, install the control in the appliance. See fig. 4.
NOTE: DO NOT overtighten the screws.
5. Align the flattened edge of the control knob’s slot with the temperature control’s shaft. Push the knob onto the shaft.
6. Fully turn the knob counterclockwise and mark #0.
7. Turn the knob clockwise until your mark aligns with #5 before powering the appliance.
NOTE: Powering the appliance when the control is set to #9 or #0 initiates test mode. To stop the test, remove power for five (5) min to reset the control. Then, set the control to #5 before reapplying power.
8. Install the relay. See “Relay Installation” (pg. 8).
A
B
Fig. 6. Existing wiring configuration (A) and the replacement wiring configuration (B).
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 7 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
Relay Installation
1. Connect the Provided Wires to the Provided Relay
1. Connect the provided wires to the provided relay as follows (see fig. 1): · White Wire with 3/16″ Red Spade Connector to Upper Left Terminal · Brown Wire with 3/16″ Red Spade Connector to Lower Left Terminal · Black Wire with 1/4″ Blue Spade Connector to COM Terminal · Brown/Red Wire with 1/4″ Blue Spade Connector to NO Terminal
2. Proceed to the appropriate section.
Upper Left (White)
845565
Lower Left (Brown)
COM (Black)
NO (Brown/Red)
Fig. 1. Provided wire locations on the provided relay terminals.
2a. Replace the Existing Relay
1. With provided lever connectors, connect the wires from the existing relay terminals (see fig. 2) to the provided relay wires as follows:
· Terminal #4 Wire to Black Relay Wire · Terminal #6 Wire to Brown/Red Relay Wire · Terminal #0 Wire to Brown Relay Wire · Terminal #1 Wire to White Relay Wire 2. Remove the existing relay.
3. Install the replacement relay in the original relay location.
4. Restore power and verify operation.
#6
#4
#0 #1
Fig. 2. Existing relay terminal configuration.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 8 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
2b. Add the Provided Relay (Appliances with an Electrical Box)
1. Access and open the electrical box. 2. With the provided lever connectors, connect the provided relay to the appliance as follows (see fig. 3).
· Black Relay Wire to Line Voltage from Main Power Cord · Brown/Red Relay Wire to Compressor/Condenser Fan Motor · Brown Relay Wire to Temperature Control Comp wire · White Relay Wire to Neutral from Main Power Cord 3. Install the relay in the electrical box. 4. Restore power and verify operation.
Appliance Power Cord
845565
N L
Relay Coil
N L Comp Aux
Temperature Control
Brown
White
Temperature Control Relay
COM
NO
Black
Existing wires New wires
Brown/Red
Compressor & Condenser Fan
Fig. 3. Relay and temperature control wiring diagram.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 9 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
2c. Add the Provided Relay (Appliances without an Electrical Box)
Appliances without electrical boxes will have one of three terminal blocks.
A. Black 4-Wire Terminal Block 1. Access the terminal block. 2. Cut the terminal block wires going to the temperature control. See fig. 4, “Cut here”. 3. With the provided lever connectors, connect the relay wires to the terminal block wires as follows (see fig. 4):
· Black Relay Wire to #3 and #4 · Brown/Red Relay Wire to #1 · Brown Relay Wire to #2 · White Relay Wire to #5 (neutral for temperature control) 4. With the provided hardware, install the relay. 5. Restore power and verify operation.
Temperature Control Comp
Temperature Control Live In Ribbed
Smooth
Smooth
Cut here
#2 #4 #1 #3
#5 Ribbed
LINE
BLACK WHITE GREEN GREEN
NEUTRAL GROUND
845565
Fig. 4. Black 4-wire terminal block diagram.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 10 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
B. White 6-Wire Terminal Block 1. Access the terminal block. 2. Cut the terminal block wires going to the temperature control. See fig. 5, “Cut here”. 3. With the provided lever connectors, connect the relay wires to the terminal block wires as follows (see fig. 5):
· Black Relay Wire to #3 and #4 · Brown/Red Relay Wire to #1 · Brown Relay Wire to #2 · White Relay Wire to #5 (neutral for temperature control) 4. With the provided hardware, install the relay. 5. Restore power and verify operation.
845565
Temperature Control Comp Smooth
Temperature Control Live In Ribbed Smooth
Cut here
#2 #4 #1 #3
#5 Ribbed
Fig. 5. White 6-wire terminal block diagram.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 11 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
C. Black/Blue 6-Wire Terminal Block 1. Access the terminal block. 2. Cut the terminal block wires going to the temperature control. See fig. 6, “Cut here”. 3. With the provided lever connectors, connect the relay wires to the terminal block wires as follows (see fig. 6):
· Black Relay Wire to #3 and #4 · Brown/Red Relay Wire to #1 · Brown Relay Wire to #2 · White Relay Wire to #5 (neutral for temperature control) 4. With the provided hardware, install the relay. 5. Restore power and verify operation.
845565
Temperature Control Comp Smooth
Ribbed
Temperature Control Live In Ribbed
Smooth
#5 #2 #4
#1 #3
Cut here
Fig. 6. Black/Blue 6-wire terminal block diagram.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 12 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
Troubleshooting
Basic Troubleshooting
In addition to reading the control indicator light codes [see “Control Indicator Light Codes Table” (pg. 13)], note the potential solutions below: · Check the terminal connections:
· If the power wires (Live In and Comp) are reversed, the control indicator lights will not light and the compressor will not start. See fig. 1. for light locations.
· If the probe wires are reversed, the control will not cycle correctly. · Check if the black probe is touching metal. If so, the probe is reading surface temperature
instead of return air temperature.
845565
Fig. 1. Indicator light locations.
Table 1. Control Indicator Light Codes
Red LED Yellow LED
Green LED Meaning
ON
OFF
ON
Defrost mode
Flashing
ON
Flashing
Mini-defrost mode
Cycling
OFF
Cycling
Pre-defrost mode
Flashing
OFF
Flashing
Drip down mode
OFF
ON
OFF1
One (1) Blink2
OFF1
Two (2) Blinks2
ON
One (1) Blink2
ON
Post-defrost recovery mode
OFF
Probe #1 faulty; good voltage
OFF
Probe #2 faulty; good voltage
OFF
Probe #1 faulty; bad voltage
ON
Two (2) Blinks2
OFF
Probe #2 faulty; bad voltage
Cycling
Cycling
Cycling
Knob set to #0 (off position)
OFF1
OFF
ON
On mode
OFF1
Flashing
ON
On mode, but compressor is off due to door switch operation
ON
OFF
OFF
Bad voltage; cooling demand
Flashing
OFF
OFF
Bad voltage; temperature satisfied
OFF
ON
OFF
Flashing
OFF
Wait mode; cooling demand
OFF
Wait mode; temperature satisfied, protection delay not over
OFF
OFF
Flashing
Wait mode; temperature satisfied, protection delay over
Flashing
Flashing
Flashing
Test mode
Cycling3
Cycling3
OFF
Bad frequency detection
Flashing
Flashing
Flashing
Internal power supply failure
NOTE: All cycling and flashing is for one (1) sec duration unless otherwise specified
1: LED comes on momentariliy during under voltage and over voltage blind time 2: Every two (2) sec 3: Every half (0.5) sec 4: Five (5) times a sec
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 13 of 16
SUBJECT TO CHANGE
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
Table 2. Temperature-to-Resitance
Table 2 shows the expected cut-in/cut/out range of the Sollatek FCA23 electronic temperature control. NOTE: This information is for diagnostic purposes only.
Temperature
°C (°F)
-10 (14.0) -9 (15.8) -8 (17.6) -7 (19.4) -6 (21.2) -5 (23.0) -4 (24.8) -3 (26.6) -2 (28.4) -1 (30.2) 0 (32.0) 1 (33.8) 2 (35.6) 3 (37.4) 5 (41.0) 6 (42.8) 7 (44.6) 9 (48.2) 10 (50.0) 11 (51.8) 12 (53.6) 13 (55.4) 14 (57.2) 15 (59.0) 16 (60.8) 17 (62.6) 18 (64.4) 19 (66.2) 20 (68.0) 21 (69.8) 22 (71.6) 23 (73.4) 24 (75.2)
Resistance
k-Ohms
548.267 519.821 492.994 467.688 443.810 421.271 399.992 379.896 360.911 342.971 326.015 309.982 294.819 280.475 254.054 241.890 230.369 209.115 199.314 190.021 181.209 172.849 164.918 157.391 150.245 143.590 197.014 130.891 125.073 119.542 114.283 109.283 104.526
Temperature
°C (°F)
25 (77.0) 26 (78.8) 27 (80.6) 28 (82.4) 29 (84.2) 30 (86.0) 31 (87.8) 32 (86.6) 33 (91.4) 34 (93.2) 35 (95.0) 36 (96.8) 37 (98.6) 38 (100.4) 39 (102.2) 40 (104.0) 41 (105.8) 42 (107.6) 43 (109.4) 44 (111.2) 45 (113.0) 46 (114.8) 47 (116.6) 48 (118.4) 49 (120.2) 50 (122.0) 60 (140.0) 70 (158.8) 80 (176.0) 90 (194.0) 100 (212.0)
Resistance
k-Ohms
100.000 95.692 91.592 87.687 83.969 90.427 77.051 93.835 70.768 67.844 65.055 62.395 59.857 57.434 55.122 52.914 50.805 48.790 46.866 45.026 43.268 41.587 39.980 38.443 36.972 35.564 24.386 17.035 12.110 8.750 6.419
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
845565
Page 14 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
Appendix
Rewiring the 4-Wire EBM Fan Motor
If the evaporator fan motor cycles or is a 4-wire motor, it must be rewired to operate correctly with the new electronic temperature control. See the procedure below. 1. Locate the black EBM wire sleeve containing black, brown, blue,
and green/yellow wires. See fig. 1.
2. Cut the black and brown fan motor wires 1″ (25.4 mm) from their respective connectors. See fig. 2.
3. With a provided 2-way lever connector, cap the black wire left attached to the original connector.
4. With a provided 2-way lever connector, cap the brown wire left attached to the original connector.
5. Strip 7/16″ (11.1 mm) of insulation from the fan motor side of the black and brown wires.
6. With a provided 3-way lever connector, connect the stripped black and brown fan motor wires to the provided bare black wire.
7. Crimp a provided spade connector to the bare black wire.
8. Connect the black wire to the temperature control Aux1 terminal. See fig. 3.
Fig. 1. The four fan motor wires and wire sleeve.
845565
Fig. 2. EBM fan motor original black and brown connections.
Fig. 3. Aux1 terminal of the replacement electronic temperature control.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 15 of 16
TRUE MANUFACTURING CO., INC.
Technical Service Instruction
Sollatek FCA23 Installation
Control Knob Cover Installation
If the control knob cover is present, install the knob cover as described below.
1. With the provided Phillips hex head screws, cut threads in the control screwholes. See fig. 4.
2. install the knob and knob cover per fig. 5. Use the provided pan head Phillips screws.
845565
Fig. 4. Cut the threads in the control screwholes.
Fig. 5. Exploded view of control knob and control knob cover installation.
BUILDING THE FINEST COMMERCIAL REFRIGERATION — True, “The Best of the Cold Ones”
TEC_WI_1407 | REV. C | EN
06/23/2023 EA | E413
Page 16 of 16