Click Pg11 V.03 Dimmer Switches Instruction Manual

PG11 V.03 Dimmer Switches

Product Information – Wiring Accessories – Dimmer Switches

The dimmer switches from the ‘Click’ range are designed for both
mains resistive and inductive loads. They can be used with low
voltage lighting, lighting devices with remote or internal
transformers, and 230V halogen lamps. The dimmer switches are
compatible with dimmable, leading edge transformers and can handle
a maximum wattage as stated below:

  • 1 gang plate – Maximum wattage: 630W (metal)
  • 2 gang plate – Maximum wattage: Unspecified

Unfurnished accessory plates and grid mounting kits are
available from ‘Click’ to customize your installation. Note that
the dimmer mounting kit is suitable for dimmers up to 400W. The
dimmer modules may be deeper than standard light switches, so it is
recommended to measure the depth of the accessory back box and use
the deepest available back box for proper fitting.

For cleaning and polishing the products, use only a soft dry
clean cloth.

Product Usage Instructions

1 Way Switched Circuit

A 1-way switched circuit is when a single switch is used to
control a single circuit. To use a 2-way switch on a 1-way circuit,
connect the Common and L1 terminals.

L1   L2   C
|    |    |
Live Switched Live
Neutral
CPC

Intermediate Switched Circuit

An intermediate switch allows for multiple switches (2 or more)
to be used on a single circuit, enabling control from different
locations. The 2-way ‘dummy’ (On/Off) dimmer can be located at both
ends if required.

L1   L2   C
|    |    |
Live Switched Live
Neutral CPC
|    |    |
L1   L2   COM
|    |    |
L1   L2

2 Way Switched Circuit

A 2-way switched circuit is when a single circuit is controlled
by 2 switches, allowing control from 2 different locations.

L1   L2   C
|    |    |
Live Switched Live
Neutral
CPC

Note: The text extract does not provide the complete technical
information for 2-way switching. Please refer to the complete user
manual or contact technical support for detailed instructions on
2-way switching.

FREQUENTLY ASKED QUESTIONS
· Q. Do these Dimmers work with dimmable LEDs? A. This will depend on the LED product itself; whether it is dimmable, a leading-edge type product and it’s harmonics. The only way to determine the compatibility of LED lamps and dimmers is to contact the lamp manufacturer directly to see if they have conducted any testing between the combination of dimmers and fittings.
· Q. The dimmer switches buzz when the lights are switched on, is this normal? A. Buzzing is part of the normal operation of a dimmer switch ­ it does not indicate a fault.
· Q. The front of the switch plate gets warm when the lights are switched on, is this normal? A. It is common for the front plate to become warm during normal operation.
·Q. What does “leading edge” mean? A. There are two main methods of dimming, “Leading edge” and “trailing edge” these are two different areas on the waveform the dimming action takes place. “Leading edge” and “Trailing edge” are not compatible with each other.
·Q. What kind of transformer should be used? A. When used with 12V low voltage lighting, the transformer should be a dimmable, leading edge transformer. Always check compatibility prior to install and if in doubt, seek advice with transformer manufacturer. We DO NOT recommend mixing electronic and magnetic transformers on the same dimmer switch.
· Q. How many lamps can I operate with each dimmer switch? A. For incandescent and halogen lamps we recommend loading to 75% of the dimmers rated load. For LED light sources you will need to contact the lamp manufacturer for compatibility.
· Q. Can you mount the dimmers above each other on multi-tier plates? A. Due to the dimmer height, the dimmers cannot be mounted above each other. Please speak to our technical team who will be able to assist.
Errors & Omissions excluded. Instructions are subject to change without notice.
PG11 V.03 Scolmore House | Mariner | Lichfield Road Industrial Estate | Tamworth | Staffordshire | B79 7UL | United Kingdom
T: +44 (0)1827 63454 | F: +44 (0)1827 63362 | E: [email protected] | www.scolmore.com

Wiring Accessories – Dimmer Switches Safety, Installation and Technical Information

Safety Information Please read the following information carefully before commencing installation.

Before commencing any electrical work, to prevent the possibility of receiving an electric shock, ensure the mains isolator on the consumer unit is in the `OFF’ position and safely isolated in accordance with Best Practice Guide 3.
If in doubt consult a qualified electrician. The accessory plate must be installed in accordance with the latest IET Wiring Regulations, BS7671.
If this product is being fitted as a replacement part to an existing installation account must be taken to the version of the wiring regulations it was installed to.

Installation Information

The `Click’ range of dimmer switches are suitable for both mains resistive and inductive loads.

When dimming low voltage lighting, or lighting devices that feature either remote or internal transformers this dimmer must be used with dimmable, leading edge transformers only.

When using 230V halogen lamps, the dimmer may be used up to its maximum stated wattage although care should be taken to ensure that only good quality branded lamps are used.

`Click’ dimmers should not be used to regulate fans or motors. The dimmer module contains a non-resetting overload device for your protection. This device will permanently switch off the dimmer in the event of an over-load fault. Once this failure has occurred, the dimmer module will need to be replaced ­ there are no user serviceable parts inside.

When installing multiple dimmer modules on one plate do not exceed the maximum loads stated below:

Maximum wattage for 1 gang plate

Maximum wattage for 2 gang plate

Plastic ­ 630W

Plastic ­ 1200W

Metal – 630W

Metal ­ 1630W

Unfurnished accessory plates and grid mounting kits are available from `Click’ to enable you to customise your installation as required. Note that the dimmer mounting kit can only be used with dimmers up to 400W.

Dimmer modules are often deeper than a standard light switch. It is recommended that careful measurements are made to ensure the dimmer will fit comfortably within the accessory back box. Where possible, the deepest available back box should be used.

For cleaning / polishing of products, use only a soft dry clean cloth.

1 Way Switched Circuit
1 way switching is when a single switch used to control a single circuit. Typically a 1 way switch will be used but a 2 way switch can also be used. To use a 2 way switch on a 1 way circuit use only the Common and L1 terminals.

L1L2 C

Live Switched Live
Neutral
CPC

X X

Intermediate Switched Circuit
An intermediate switch allows for multiple switches (2 or more) to be used on a single circuit, meaning a circuit can be turned on or off from different locations. The 2 way `dummy’ (On/Off) dimmer can be located at both ends if required.

Live Switched Live

Neutral CPC

L1L2 C

L1

L1

L2

L2

COM

L1

L2

2 Way Switched Circuit
2 way switching is when a single circuit is controlled 2 switches, enabling the user to control the circuit from 2 locations. A typical Example is below.

Live Switched Live
Neutral
CPC

X

L1L2 C

COM

L1

L2

Technical Information

2 way switching is when a single circuit is controlled 2 switches, enabling the

Voltage user to control the circu2i4t 0frVo~m520Hlozcations. A typical Example is below. The 2 way `dummy’ (On/Off) dimmer can be located at both ends if required.

Load Types

Resistive / Inductive

Module Type Terminal Size Cable Size

SLweiatcdhinegdELLdiigvveee Technology
3.5mmNøeutral CPC
2 x 1.5mm2

Back Box Depth (Min)
L1L2 C

X

25mm (Deco, Deco+ Mode, Polar, Curva) 35mm (Define,Definity) L1L2 C

X

Operational Temperature Standards

-50 to +450C
The Low Voltage Directive 2014/35/EC Statutory Instruments 2014/35 BS EN 60669-1 BS EN 61000 BS EN 55015

Dimmer modules MD9022 and MD9042 are not suitable for mounting above each other on multi-tier mounting plates. Please speak to our technical team who will be able to assist.