Illusion 47 Built In Direct Vent Fireplace
Product Information
The product is a gas fireplace with a safety barrier, direct
venting, and a clear view glass. It has a maximum BTU of 24,000 for
both natural gas and LP. The minimum BTU for natural gas is 17,000
and for LP is also 17,000. The glass dimensions are 41.6875 x 16.75
with a surface area of 698 sq in. The height, depth, and width of
the fireplace are 39.0625, 18.3125, and 46.875 respectively. The
framing dimensions are 41.5 in height, 18.625 in depth, and 47.375
in width. The optional blower has a heat-activated type with six
speeds and 150 CFM. It requires a shelf depth of 6 inches and a
height of 43 inches from the bottom of the fireplace.
Product Usage Instructions
GAS COLLECTION
The minimum framing dimensions for gas collection are 3.1. The
minimum clearance from the top of the horizontal vent pipe to
combustible materials can be reduced from 3” (76mm) to 1” (25mm)
in installations with a minimum 38” (96.5cm) vertical vent rise
made immediately off the appliance collar. The vent shield is
telescopic and must be adjusted to shield the full depth of the
combustible wall penetration.
SIDE WALL
Keep objects at least 4 feet away from the appliance. A, B, C,
D, E, and F represent the minimum clearances from the appliance for
the measurements mentioned in the text.
CEILING
The minimum clearance from the base of the appliance to the
ceiling is 14 inches (35.6 cm). The minimum clearance to
combustible header is B, which is 47 3/8” (120.3cm). The minimum
clearance to combustible drywall is G, which is 39 3/8”
(100cm).
FRAMING AND CLEARANCES
The minimum clearance to combustible enclosures is 10.3. Use
firestop spacer W010-4404 (supplied) when passing through a wall
and use firestop spacer W500-0096 (not supplied) when passing
through a ceiling. The minimum clearance to combustible mantel is
shown in the table with mantel depth ranging from 0 to 10
inches.
Optional heat management system
The product comes with an optional heat management system.
Contact the manufacturer for more information.
Model: Illusion® 47
SAFETY BARRIER
Front view
Illusion®
GAS COLLECTION
Left view
Top view
Max NG 24,000
BTU
Max LP
Min NG
24,000
17,000
Min LP 17,000
Type Direct
VENTING
Max. Height In & Out Diameter
35 feet
4″ & 7″
Type Clear View
GLASS Dimensions 41.6875″ x 16.75″
Surface 698 sq in
DIMENSIONS
Height
Depth
Width
39.0625″ 18.3125″ 46.875″
FRAMING DIMENSIONS
Height
Depth
Width
41.5″
18.625″ 47.375″
OPTIONAL BLOWER
MANTEL SHELF CLEARANCE
Type
CFM Shelf depth Height from bottom of fireplace
Heat Activated, 6 speeds 150
6″
43″
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com
Illusion®
GAS COLLECTION
Model: Illusion® 47
Framing and Clearances 3.1 minimum framing dimensions
note:
The minimum clearances from the top of the horizontal vent pipe to combustible materials may be reduced from 3” (76mm) to 1” (25mm) in those installations with a minimum 38” (96.5cm) vertical vent rise made immediately off the appliance collar.
SIDE WALL
Do not put objects in front of the appliance (minimum distance of 4 feet)*
A B C D E F
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com
18 9/16” (47.1cm) 47 3/8” (120.3cm) 42 1/2” (107.9cm)
6 5/16” (16cm) 60 3/16” (152.9cm)
6” (15.2cm)
Model: Illusion® 47
Framing and Clearances
Illusion®
GAS COLLECTION
WARNING
· Do not build this area – it must be left clear to provide adequate clearance for the vent in this 14” (35.6cm) wide area centered along the front of the appliance. The appliance should be in its final location before framing.
CEILING
MINIMUM FROM BASE OF APPLIANCE
14′ (35.6 CM)
MIN
COMBUSTIBLE HEADER
DRYWALL
B
47 3/8” (120.3cm)
G
39 3/8” (100cm)
A
18 9/16” (47.1cm)
H
56” (142.2cm)
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com
Model: Illusion® 47
Framing and Clearances
10.3 minimum clearance to combustible enclosures
note:
When passing through a wall, use firestop spacer W010-4404 (supplied). When passing through a ceiling, use firestop spacer W500-0096 (not supplied).
Illusion®
GAS COLLECTION
note:
The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.
*See «venting requirements» and «venting installation» sections. ** Clearances within the enclosure may be higher, see «minimum framing dimensions» section.
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com
Illusion®
GAS COLLECTION
Model: Illusion® 47
Framing and Clearances
11.2 minimum clearance to combustible enclosures
WARNING
· Non-combustible facing material must not project more than 4” (102mm) from the face of the door (all three sides). If greater projections are desired, increase the clearance to the sides and top by 2” (51mm) for every additional 1” (25mm) of projection. If using an optional surround, the same rules applies, starting from the top of the surround. Ensure clearances are maintained for surround removal, as it must life of the appliance for maintenance.
K
48” (121.9cm)
L
42 1/2” (107.9cm)
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com
Model: Illusion® 47
Framing and Clearances
Minimum combustible mantel clearances
26 24 22 20 18 16 14 12 10 8 6 4 0
1 2 3 4 5 6 7 8 9 10 MANTEL DEPTH
Illusion®
GAS COLLECTION
OP Q R
Hood
Appliance Opening
A
24 22 20 18 16 14 12 10 8 6 4 2 0
2 4 6 8 10 121416182022 MANTEL DEPTH
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com
Model: Illusion® 47
Framing and Clearances Clearances around appliance (TV and valuable objects)
Illusion®
GAS COLLECTION
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com
Model: Illusion® 47
Optional heat management system
Illusion®
GAS COLLECTION
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com