Ambiance Illusion 47 Built In Direct Vent Fireplace Owner's Manual

Illusion 47 Built In Direct Vent Fireplace

Product Information

The product is a gas fireplace with a safety barrier, direct
venting, and a clear view glass. It has a maximum BTU of 24,000 for
both natural gas and LP. The minimum BTU for natural gas is 17,000
and for LP is also 17,000. The glass dimensions are 41.6875 x 16.75
with a surface area of 698 sq in. The height, depth, and width of
the fireplace are 39.0625, 18.3125, and 46.875 respectively. The
framing dimensions are 41.5 in height, 18.625 in depth, and 47.375
in width. The optional blower has a heat-activated type with six
speeds and 150 CFM. It requires a shelf depth of 6 inches and a
height of 43 inches from the bottom of the fireplace.

Product Usage Instructions

GAS COLLECTION

The minimum framing dimensions for gas collection are 3.1. The
minimum clearance from the top of the horizontal vent pipe to
combustible materials can be reduced from 3” (76mm) to 1” (25mm)
in installations with a minimum 38” (96.5cm) vertical vent rise
made immediately off the appliance collar. The vent shield is
telescopic and must be adjusted to shield the full depth of the
combustible wall penetration.

SIDE WALL

Keep objects at least 4 feet away from the appliance. A, B, C,
D, E, and F represent the minimum clearances from the appliance for
the measurements mentioned in the text.

CEILING

The minimum clearance from the base of the appliance to the
ceiling is 14 inches (35.6 cm). The minimum clearance to
combustible header is B, which is 47 3/8” (120.3cm). The minimum
clearance to combustible drywall is G, which is 39 3/8”
(100cm).

FRAMING AND CLEARANCES

The minimum clearance to combustible enclosures is 10.3. Use
firestop spacer W010-4404 (supplied) when passing through a wall
and use firestop spacer W500-0096 (not supplied) when passing
through a ceiling. The minimum clearance to combustible mantel is
shown in the table with mantel depth ranging from 0 to 10
inches.

Optional heat management system

The product comes with an optional heat management system.
Contact the manufacturer for more information.

Model: Illusion® 47
SAFETY BARRIER
Front view

Illusion®
GAS COLLECTION
Left view

Top view

Max NG 24,000

BTU

Max LP

Min NG

24,000

17,000

Min LP 17,000

Type Direct

VENTING

Max. Height In & Out Diameter

35 feet

4″ & 7″

Type Clear View

GLASS Dimensions 41.6875″ x 16.75″

Surface 698 sq in

DIMENSIONS

Height

Depth

Width

39.0625″ 18.3125″ 46.875″

FRAMING DIMENSIONS

Height

Depth

Width

41.5″

18.625″ 47.375″

OPTIONAL BLOWER

MANTEL SHELF CLEARANCE

Type

CFM Shelf depth Height from bottom of fireplace

Heat Activated, 6 speeds 150

6″

43″

Ambiance® Fireplaces & Grills www.ambiancefireplaces.com

Illusion®
GAS COLLECTION
Model: Illusion® 47
Framing and Clearances 3.1 minimum framing dimensions
note:
The minimum clearances from the top of the horizontal vent pipe to combustible materials may be reduced from 3” (76mm) to 1” (25mm) in those installations with a minimum 38” (96.5cm) vertical vent rise made immediately off the appliance collar.
SIDE WALL

Do not put objects in front of the appliance (minimum distance of 4 feet)*

A B C D E F
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com

18 9/16” (47.1cm) 47 3/8” (120.3cm) 42 1/2” (107.9cm)
6 5/16” (16cm) 60 3/16” (152.9cm)
6” (15.2cm)

Model: Illusion® 47
Framing and Clearances

Illusion®
GAS COLLECTION

WARNING
· Do not build this area – it must be left clear to provide adequate clearance for the vent in this 14” (35.6cm) wide area centered along the front of the appliance. The appliance should be in its final location before framing.

CEILING

MINIMUM FROM BASE OF APPLIANCE

14′ (35.6 CM)
MIN

COMBUSTIBLE HEADER

DRYWALL

B

47 3/8” (120.3cm)

G

39 3/8” (100cm)

A

18 9/16” (47.1cm)

H

56” (142.2cm)

Ambiance® Fireplaces & Grills www.ambiancefireplaces.com

Model: Illusion® 47
Framing and Clearances
10.3 minimum clearance to combustible enclosures
note:
When passing through a wall, use firestop spacer W010-4404 (supplied). When passing through a ceiling, use firestop spacer W500-0096 (not supplied).

Illusion®
GAS COLLECTION

note:
The vent shield is telescopic and must be adjusted to shield the full depth of the combustible wall penetration.

*See «venting requirements» and «venting installation» sections. ** Clearances within the enclosure may be higher, see «minimum framing dimensions» section.

Ambiance® Fireplaces & Grills www.ambiancefireplaces.com

Illusion®
GAS COLLECTION
Model: Illusion® 47
Framing and Clearances
11.2 minimum clearance to combustible enclosures
WARNING
· Non-combustible facing material must not project more than 4” (102mm) from the face of the door (all three sides). If greater projections are desired, increase the clearance to the sides and top by 2” (51mm) for every additional 1” (25mm) of projection. If using an optional surround, the same rules applies, starting from the top of the surround. Ensure clearances are maintained for surround removal, as it must life of the appliance for maintenance.

K

48” (121.9cm)

L

42 1/2” (107.9cm)

Ambiance® Fireplaces & Grills www.ambiancefireplaces.com

Model: Illusion® 47
Framing and Clearances
Minimum combustible mantel clearances
26 24 22 20 18 16 14 12 10 8 6 4 0
1 2 3 4 5 6 7 8 9 10 MANTEL DEPTH

Illusion®
GAS COLLECTION

OP Q R
Hood

Appliance Opening

A

24 22 20 18 16 14 12 10 8 6 4 2 0
2 4 6 8 10 121416182022 MANTEL DEPTH
Ambiance® Fireplaces & Grills www.ambiancefireplaces.com

Model: Illusion® 47
Framing and Clearances Clearances around appliance (TV and valuable objects)

Illusion®
GAS COLLECTION

Ambiance® Fireplaces & Grills www.ambiancefireplaces.com

Model: Illusion® 47
Optional heat management system

Illusion®
GAS COLLECTION

Ambiance® Fireplaces & Grills www.ambiancefireplaces.com