Mean Well Apv-12 Series 12w Single Output Switching Power Supply Owner's Manual

APV-12 Series 12W Single Output Switching Power Supply

Product Information

The APV-12 series is a 12W single output switching power supply.
It is designed to provide DC voltage output with various current
and voltage options. The power supply is compliant with safety
standards UL8750, CSA C22.2 No.250.0-08, BIS IS15885 (except for
15V), EAC TP TC 004, IP42, and BS EN/EN 62368-1.

Specifications:

  • Model: APV-12-5
  • Output:
    • DC Voltage: 5V
    • Rated Current: 2A
    • Current Range: 0 ~ 2A
    • Rated Power: 10W
    • Ripple & Noise (max.): 100mVp-p
    • Line Regulation
    • Load Regulation
    • Setup, Rise Time: 1500ms, 30ms / 230VAC; 1500ms, 30ms / 115VAC
      at full load
    • Hold Up Time (Typ.): 20ms/230VAC, 15ms/115VAC at full load
    • Voltage Range: 90 ~ 264VAC, 127 ~ 370VDC
    • Frequency Range: 47 ~ 63Hz
    • Efficiency (Typ.): 76%
    • AC Current: 0.2A/230VAC, 0.35A/115VAC
    • Inrush Current (Typ.): Cold Start 70A (twidth=185s measured at
      50% Ipeak) at 230VAC
    • Max. No. of PSUs on 16A Circuit Breaker Leakage Current: 17
      units (circuit breaker of type B) / 29 units (circuit breaker of
      type C) at 230VAC; 0.25mA / 240VAC
    • Over Load Protection: Above 105% rated output power, Protection
      type: Hiccup mode, recovers automatically after fault condition is
      removed
    • Over Voltage: 5.75 ~ 6.75V
    • Working Temperature: -30 ~ +70 (Refer to Derating Curve)
    • Working Humidity: 20 ~ 90% RH non-condensing
    • Environment Storage Temp., Humidity: -40 ~ +80, 10 ~ 95%
      RH
    • Temp. Coefficient Vibration: 10 ~ 500Hz, 2G 10min./1cycle,
      period for 60min. each along X, Y, Z axes
    • Safety Standards: UL8750, CSA C22.2 No.250.0-08, BIS IS15885
      (except for 15V), EAC TP TC 004, IP42, BS EN/EN 62368-1
      approved
    • Safety & Withstand Voltage EMC: I/P-O/P:3.75KVAC,
      I/P-O/P:>100M Ohms / 500VDC / 25/70% RH, Compliance to BS
      EN/EN55032, BS EN/EN61000-3-2, BS EN/EN61000-3-3, EAC TP TC
      020
    • EMC Immunity: Compliance to BS EN/EN55035, BS EN/EN61000-4-2,
      3, 4, 5, 6, 8, 11; light industry level (surge 2KV), EAC TP TC
      020
    • MTBF: 7488.9K hrs min. Telcordia SR-332 (Bellcore); 1132.5K hrs
      min. MIL-HDBK-217F (25)
    • Dimension: 77*40*29 (L*W*H)
    • Packing: 0.08Kg; 120pcs/11.8Kg/1.06CUFT
    • Note: All parameters NOT specially mentioned are measured at
      230VAC input, rated load and 25°C of ambient temperature. Ripple
      & noise are measured at 20MHz of bandwidth by using a 12
      twisted pair-wire terminated with a 0.1uf & 47uf parallel
      capacitor. Tolerance includes set up tolerance, line regulation,
      and load regulation. Derating may be needed under low input
      voltage. Please check the static characteristics for more
      details.
    • Please connect L line to the positive pole and N line to the
      negative pole under DC input.
    • The power supply is considered as a component that will be
      operated in combination with final equipment. Since EMC performance
      will be affected by the complete installation, the final equipment
      manufacturers must re-qualify EMC Directive on the complete
      installation again.
    • Length of set up time is measured at first cold start. Turning
      ON/OFF the power supply may lead to an increase in the set up
      time.
    • This product is not intended for LED lighting luminaire
      applications in the EU. (In the EU, the LPF/NPF/XLG series are
      recommended.)

Product Usage Instructions

To use the APV-12 series single output switching power supply,
follow these steps:

  1. Ensure that the input voltage is within the range of 90 ~
    264VAC or 127 ~ 370VDC and the frequency is between 47 ~ 63Hz.
  2. Connect the L line to the positive pole and the N line to the
    negative pole under DC input.
  3. Select the desired output voltage according to your
    requirements:
  • For APV-12-5: Set the output voltage to 5V.
  • For APV-12-12: Set the output voltage to 12V.
  • For APV-12-15: Set the output voltage to 15V.
  • Connect your device or equipment to the power supply’s output
    terminals.
  • Ensure that the load does not exceed the rated current for each
    model:
    • For APV-12-5: The rated current is 2A with a current range of 0
      ~ 2A.
    • For APV-12-12: The rated current is 1A with a current range of
      0 ~ 1A.
    • For APV-12-15: The rated current is 0.8A with a current range
      of 0 ~ 0.8A.
  • Ensure that the working temperature is within the range of
    -30°C to +70°C. Refer to the Derating Curve for more details.
  • Make sure the working humidity is between 20% and 90% RH
    non-condensing.
  • Observe the safety standards and isolation resistance for
    proper operation and compliance.

    12W Single Output Switching Power Supply

    APV-12 series

    SPECIFICATION
    MODEL

    APV-12-5

    User’s Manual

    IS 15885(Part 2/Sec13)

    LPS IP42

    THOMAS SAMUEL

    THOMAS SAMUEL

    R-41027766

    APV-12-12

    APV-12-15

    APV-12-24

    OUTPUT

    DC VOLTAGE

    5V

    12V

    15V

    RATED CURRENT

    2A

    1A

    0.8A

    CURRENT RANGE

    0 ~ 2A

    0 ~ 1A

    0 ~ 0.8A

    RATED POWER

    10W

    12W

    12W

    RIPPLE & NOISE (max.) Note.2 100mVp-p

    120mVp-p

    120mVp-p

    VOLTAGE TOLERANCE Note.3 ±5.0%

    LINE REGULATION

    ±1.0%

    LOAD REGULATION

    ±2.0%

    SETUP, RISE TIME Note.6 1500ms, 30ms / 230VAC

    1500ms,30ms / 115VAC at full load

    HOLD UP TIME (Typ.)

    20ms/230VAC 15ms/115VAC at full load

    24V 0.5A 0 ~ 0.5A 12W 150mVp-p

    VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC

    FREQUENCY RANGE

    47 ~ 63Hz

    INPUT

    EFFICIENCY (Typ.)

    76%

    82%

    82%

    84%

    AC CURRENT

    0.2A/230VAC 0.35A/115VAC

    INRUSH CURRENT(Typ.)

    COLD START 70A(twidth=185s measured at 50% Ipeak) at 230VAC

    MAX. No. of PSUs on 16A CIRCUIT BREAKER LEAKAGE CURRENT

    17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC 0.25mA / 240VAC

    OVER LOAD PROTECTION
    OVER VOLTAGE
    WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION

    Above 105% rated output power

    Protection type : Hiccup mode, recovers automatically after fault condition is removed

    5.75 ~ 6.75V

    13.8 ~ 16V

    17.5 ~ 21V

    Protection type : Shut off o/p voltage, clamping by zener diode

    -30 ~ +70(Refer to “Derating Curve”)

    20 ~ 90% RH non-condensing

    -40 ~ +80, 10 ~ 95% RH

    ±0.03%/ (0 ~ 50)

    10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

    27.6 ~ 32.4V

    SAFETY STANDARDS Note.8

    UL8750,CSA C22.2 No.250.0-08, BIS IS15885(except for 15V),EAC TP TC 004,IP42, BS EN/EN 62368-1 approved

    SAFETY & WITHSTAND VOLTAGE

    EMC

    ISOLATION RESISTANCE

    EMC EMISSION

    I/P-O/P:3.75KVAC I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS EN/EN61000-3-3, EAC TP TC 020

    EMC IMMUNITY

    Compliance to BS EN/EN55035,BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), EAC TP TC 020

    MTBF

    7488.9K hrs min. Telcordia SR-332 (Bellcore) ; 1132.5K hrs min. MIL-HDBK-217F (25)

    OTHERS DIMENSION

    77*40*29(L*W*H)

    PACKING

    0.08Kg; 120pcs/11.8Kg/1.06CUFT

    NOTE

    1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

    3. Tolerance : includes set up tolerance, line regulation and load regulation.

    4. Derating may be needed under low input voltage. Please check the static characteristics for more details. Please connect L line to the positive pole and

    N line to the negative pole under DC input.

    5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the

    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

    6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

    7. This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)

    8. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.

    9. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

    10. Products sourced from the Americas regions may not have the ENEC/BIS/CCC logo. Please contact your MEAN WELL sales for more information.

    11. For any application note and IP water proof function installation caution, please refer our user manual before using.

    https://www.meanwell.com/Upload/PDF/LED_EN.pdf

    Downloaded from Arrow.coPmro.duct Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:APV-12-SPEC 2023-04-14

    12W Single Output Switching Power Supply
    Mechanical Specification
    90 82.5 77

    AC/N(Blue) AC/L(Brown)

    UL1569 18AWG 150±10

    31 T case
    T case: Max. Case Temperature

    APV-12 series
    Unit:mm

    150±10 UL1569 20AWG

    +V(Red) -V(Black)

    40 15.5
    19 29

    Block Diagram

    I/P

    EMI FILTER

    RECTIFIERS

    POWER SWITCH-
    ING
    PWM CONTROL

    RECTIFIERS &
    FILTER

    DETECTION CIRCUIT

    fosc : 67KHz
    +V -V

    Derating Curve

    Static Characteristics

    100
    80
    60 50 40
    20
    -30

    other 5V

    0 10 20 30

    40 45 50 60

    70 (HORIZONTAL)

    AMBIENT TEMPERATURE ()

    100 90 80 70 60 50 40

    90 100 200 210 220 230 240 250

    264

    INPUT VOLTAGE (VAC) 60Hz

    LOAD (%) LOAD (%)

    Downloaded from Arrow.com.