Lowe S Blobfish 3-light Polished Gold Modern/contemporary Led Dry Rated Chandelier Instruction Manual

Blobfish 3-Light Polished Gold Modern/Contemporary LED Dry rated Chandelier

Product Information:

Item Number: A04970C3

Maximum Wattage: Type B, Max 40W per bulb

Voltage: 120V

Contact Number: +1 850 296 2377

Working Hours: Mon – Fri 9:00 – 16:00 EST

Email: [email protected]

Product Usage Instructions:

  1. We strongly recommend installation by a licensed
    electrician.
  2. Read the instruction carefully and save it for future
    reference.
  3. Before starting any work, always shut off the electricity.
  4. Ensure that the mounting surface is clean, dry, flat, and
    strong enough to support the product. It should also be 1/4 larger
    than the canopy on all sides. Correct any gaps exceeding 3/16 as
    required.
  5. Check if the ceiling or wall can withstand the weight of the
    lamp before installation.
  6. Use only 120V voltage and Type B bulbs with a maximum wattage
    of 40W per bulb.
  7. Avoid exposing the lamp to acidic and alkaline substances, as
    they may damage the surface.
  8. When replacing bulbs, turn off or unplug the lamp and wait
    until it cools down.
  9. These safety instructions do not cover all possible conditions.
    Use common sense, caution, and care when dealing with electrical
    products.

Tools Required:

  • Ladder
  • Philips Head or Flat Blade Screwdriver
  • Electrical Tape
  • Pliers
  • Wire Cutter/Stripper

Parts Included:

  • (C) Single bar – 1
  • (D) Green ground screw – 1
  • (E) Canopy – 1
  • (F) Collar ring – 1
  • (G) Collar loop – 1
  • (H) Quick link – 2
  • (I) Chain – 1
  • (J) Loop – 1
  • (K) Stem – 1
  • (L) Arm assembly – 1
  • (M) Arm – 3
  • (N) Socket – 3
  • (O) Glass shade – 3
  • (P) Socket ring – 3

Accessories Included:

  • (A) Wire connector – 3
  • (B) Mounting screw – 2

Assembly and Installation Instructions:

  1. Remove the fixture from the carton and ensure all parts and
    accessories are included.
  2. Make pre-installation adjustments using chain pliers and
    discard any unwanted parts.
  3. Turn off the power before starting the installation.
  4. Install the fixture using the provided mounting screws. Ensure
    the side of the single bar marked GND faces out.
  5. Adjust the collar loop on the single bar assembly until the
    desired secure length is achieved.
  6. Pass the fixture wires through the collar loop to the top of
    the pre-assembled threaded nipple and gently pull to ensure the
    wires are not stressed.

If you have any further questions or need assistance, please
contact us during working hours at +1 850 296 2377 or email us at
[email protected].

+1 850 296 2377 Working hours : Mon – Fri 9:00 – 16:00 EST

[email protected]

Item Number: A04970C3
WARNING (To reduce the risk of fire, electric shock, or personal injury): 1. We suggest installation by a licensed electrician. 2. Please read the instruction carefully and save it as you may need it at a later time. 3. Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position.
4. Mounting surface should be clean, dry, flat, strong enough and 1/4″ larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16″ should be corrected as required.
5. Make sure that the ceiling or wall can stand the weight of the lamp before installation. 6. Make sure the voltage you are using is 120V. The maximum wattage is Type B, Max 40W per bulb. 7. Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp. 8. When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot
quickly. 9. The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It
must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT:

TOOLS REQUIRED Before starting assembly and installation please prepare the needed (NOT INCLUDED): tools as below picture

Ladder

Philips Head or Flat Blade Screwdriver

Electrical Tape

Pliers

Wire Cutter/Stripper
Page: – 1 – / 4

+1 850 296 2377 Working hours : Mon – Fri 9:00 – 16:00 EST
PARTS TYPE & QTY INCLUDING:
(C) Single bar (1) (D) Green ground screw (1) (E) Canopy (1) (F) Collar ring (1) (G) Collar loop (1) (H) Quick link (2) (I) Chain (1) (J) Loop (1) (K) Stem (1) (L) Arm assembly (1) (M) Arm (3) (N) Socket (3) (O) Glass shade (3) (P) Socket ring (3)
ACCESSORIES & QTY ENCLOSED:
(A) Wire connector (3) (B) Mounting screw (2)

[email protected]

ASSEMBLY & INSTALLATION INSTRUCTIONS:
1. Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
2. Make pre-installation

Step A1 » Screw stem (K) onto the top of arm assembly (L).

Page: – 2 – / 4

+1 850 296 2377 Working hours : Mon – Fri 9:00 – 16:00 EST

[email protected]

Step A2 » By measuring, determine the correct number of links needed for proper hanging height. Using the
chain pliers, disconnect and discard the unwanted part.
Step A3 » Attach quick link (H) to chain (I) and loop (J) on the top of stem (K).

Step A4 » Carefully weave the fixture wires through chain (I) in and out of every other link and stop just when
you reach the top of chain (I). Gently pull the wires to ensure the wires are not stressed.

3. Turn off power Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.
» Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
» Place the wall switch in the “OFF” position.

4. Make installation

Step B1 » Remove collar ring (F) from collar loop (G). Attach single bar (C) to the outlet box with mounting
screws (B).
Note: the side of single bar (C) marked “GND” must face out.
Step B2 » Raise canopy (E) over collar loop (G) and screw collar ring (F) to measure a proper position.
NOTE: canopy (E) should be snug against the ceiling and collar loop (G) should be screwed enough threads (no less than 6 threads) on the preassembled threaded nipple for more secure hanging. If not, adjust collar loop (G) on single bar assembly (C) by screwing collar loop (G) in or out of single bar (C) until the secure length is achieved.
Page: – 3 – / 4

+1 850 296 2377 Working hours : Mon – Fri 9:00 – 16:00 EST

[email protected]

Step B3 » Pass chain (I) through collar ring (F) and then through canopy (E).
Step B4 » Open quick link (H), attach quick link (H) to collar loop (G). Close quick link (H).
Pass the fixture wires through collar loop (G) to the top of the pre-assembled threaded nipple and gently pull to ensure the wires are not stressed.
Step B5 » If needed, shorten the length of fixture wires. At this point, the remaining wire length measured
above single bar (C) is at least 6″.

Step B6 » Make wire connections
Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.

Connect ground wires according to the below chart

A

B

Connect wires according to the below chart

Connect Black or Red Supply Wire to:

Connect White Supply Wire to:

OUTLET BOX GROUND GREEN GROUND SCREW

OUTLET BOX GROUND
FIXTURE GROUND

DIMPLES

GREEN GROUND SCREW

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

FIXTURE GROUND

Clear, Brown, Gold or Black without tracer
Insulated wire(other than green) with copper conductor

Clear, Brown, Gold or Black with tracer
Insulated wire(other than green) with silver conductor

CUPPED WASHER

* Note: When parallel wires (SPT I& SPT ll) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)

Neutral Wire

· Twist wires together with plastic wire connectors until tightly joined. · Wrap each connector with approved electrical tape. · Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.

Step B7 » Raise canopy (E) to the ceiling and secure canopy (E) in place by tightening collar ring (F) onto
collar loop (G).

Step B8 » 1) Remove socket rings (P) from sockets (N)
2) Carefully place glass shades (O) to sockets (N), and then screw sockets rings (P) to sockets (N) to secure them.
3) Install bulbs (not included) (Please do not exceed the maximum wattage recommended on the socket.)
5. Check everything is already installed properly, then you could turn on the light. Enjoy!

ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement parts. All parts for this fixture can be ordered from the place of purchase. Be sure to use exact wording from illustration when ordering parts.

CLEANING
To clean, wipe the fixture with a soft cloth. Clean glass with a mild cleaner (such as mild and non-abrasive soap). Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.

Page: – 4 – / 4

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals