Senville 36,000 Btu Dual Zone Mini Split Heat Pump Instruction Manual

36,000 BTU Dual Zone Mini Split Heat Pump

Product Information

  • Model: A24185
  • Air freshening filter included
  • Outdoor unit dimensions:
    • Model A: 29.5″ x 21.3″ x 9.4″
    • Model B: 30.7″ x 21.3″ x 9.8″
    • Model C: 29.9″ x 23.2″ x 11.2″
    • Model D: 33.3″ x 27.6″ x 12.6″
  • Mounting dimensions:
    • A(mm/inch): 458/18, B(mm/inch): 250/9.8 (Model A)
    • A(mm/inch): 549/21.6, B(mm/inch): 530/20.9 (Model B)
    • A(mm/inch): 276/10.9, B(mm/inch): 290/11.4 (Model C)
    • A(mm/inch): 549/21.6, B(mm/inch): 560/22.1 (Model C)
    • A(mm/inch): 325/12.8, B(mm/inch): 335/13.2 (Model D)
    • A(mm/inch): 333/13.1, B(mm/inch): 640/25.2 (Model D)

Product Usage Instructions

  1. Drill a 65mm (2.6inch) hole on the wall which is slightly
    tilted towards the outside.
  2. Ensure a minimum distance of 12cm/4.7in or more from any
    obstruction.
  3. Ensure a minimum distance of 60cm/23.6in or more from the
    ceiling or any upper obstruction.
  4. Ensure a minimum distance of 30cm/11.8in or more from the floor
    or any lower obstruction.
  5. For model A, use mounting dimensions A(mm/inch): 458/18 and
    B(mm/inch): 250/9.8.
  6. For model B, use mounting dimensions A(mm/inch): 549/21.6 and
    B(mm/inch): 530/20.9.
  7. For model C, use mounting dimensions A(mm/inch): 276/10.9 and
    B(mm/inch): 290/11.4.
  8. For model D, use mounting dimensions A(mm/inch): 549/21.6 and
    B(mm/inch): 560/22.1.

16122000A24185

12cm/4.7in or more

12cm/4.7in or more

60cm/23.6in or more 2.3m/7.5ft or more

30cm/11.8in or more 2m/6.6ft or more

30cm/11.8in or more 60cm/23.6in or more

6
Air freshening filter(1) (used to install on Air filter)

15cm/5.9in or more

Outdoor unit dimension mm/inch(WxHxD) (29.5×21.3×9.4) (30.7×21.3×9.8)
(29.9×23.2×11.2)
810x558x310(31.8×21.9×12.2) (33.3×27.6×12.6)
900x860x315(35.4×33.9×12.4)
945x810x395(37.2×31.9×15.6)

Mounting dimensions

A(mm/inch)

B(mm/inch)

458(18)

250(9.8)

549(21.6) 530(20.9)

276(10.9) 2 9 0 ( 1 1 . 4)

549(21.6)
560(22.1) 590(23.2)

325(12.8) 335(13.2)
333(13.1)

640(25.2)

405(15.9)

180/7.1

0.2in (Unit:mm/inch) Indoor unit outline
110/4.3

36.5/1.4 45/1.8
280/11

45/1.8

Left rear side refrigerant pipe hole
65/2.6 140/5.5

750/29.5 Model A

Right rear side refrigerant pipe hole
65/2.6

Indoor unit outline 110/4.3

36.5/1.4 45/1.8
280/11

45/1.8

Left rear side refrigerant pipe hole
65/2.6

835/32.9 Model B

Right rear side refrigerant pipe hole
65/2.6

Indoor unit outline

315/12.4

Left rear side refrigerant pipe hole
65/2.6

23.2/0.9 260/10.2

990/39 Model C

135/5.3

Right rear side 45/1.8refrigerant
pipe hole 65/2.6

257/10.1

Indoor unit outline 275/10.8

21.5/0.85 45/1.8 343/13.5

Left rear side refrigerant pipe hole
65/2.6

1186/46.7
Model D

Right rear side refrigerant pipe hole
65/2.6

3m(9.8ft)

5m(16.4ft)

(16.4ft)

6.35mm/1/4in
30g(1.06oz) 15g(0.53oz) (For Inverter type) 20g(0.71oz)

9.52mm/3/8in
60g(2.12oz)
30g(1.06oz) (For Inverter type)
40g(1.41oz)

6.35mm/1/4in 9.52mm/3/8in 12.7mm/1/2in 15.88mm/5/8in

Tightening torque Additional tightening

(N.cm/lbf.in)

torque(N.cm/lbf.in)

1500/132.8

1600/141.59

2500/221.34

2600/230.02

3500/309.73

3600/318.56

4500/398.23

4700/415.93

Suggest Minimum Wire Size (AWG:American Wire Gage):

Appliance Amps

AWG Wire Size

10

18

13

16

18

14

25

12

30

10

Outdoor unit Terminal block Over 1 3/5in.(40mm)
G
Cover control

Conduit panel
Connecting cable Power supply cord

115V~ models

L NS

G

1(L) 2(N) S L N

Power supply
208-230V~ models

L1 L 2 S

G

L1 L2 S L1 L2
Power supply

(0.2~0.3inch)

Drill a 65mm(2.6inch) hole on the wall which is slightly tilted towards the outside.
62OF

Documents / Resouces

Download manual