Submittal E4hl5018a1000a Split System Heat Pump User Manual

E4HL5018A1000A Split System Heat Pump

Product Information:

The product is a Split System Heat Pump with the model number
E4HL5018A1000A. The dimensions of the outdoor unit are as follows:
A- 31.35 inches, B- 35.83 inches, C- 14.13 inches, D- 15.36 inches,
E- 16.59 inches, F- 5.97 inches, G- 6.07 inches, H- 3.71 inches, I-
6.09 inches. The model has a sound power level of 58 dB(A) at 63Hz.
It uses a rotary compressor and has one stage of heat. The outdoor
fan has a diameter of 21-5/8 inches and is driven by a direct
variable speed motor. The motor operates at 2700 RPM and requires
208/230 volts and 1.1 amps. The outdoor coil is a plate fin type
with 1 row and 21 fins per inch. The refrigerant control is an
electric expansion valve.

Product Usage Instructions:

1. Installation: Follow the installation instructions provided
in the user manual to properly install the Split System Heat Pump.
Ensure that the unit is placed in a suitable location with proper
clearance for airflow and maintenance.

2. Power Connection: Connect the power supply to the outdoor
unit using the specified voltage, phase, and frequency (208/230
volts, single phase, 60Hz). Use HACR circuit breakers or fuses for
electrical protection.

3. Circuit Ampacity: Check the minimum circuit ampacity required
for the unit based on the RLA (Rated Load Amps) value indicated on
the unit nameplate and specification sheet. Ensure that the circuit
ampacity meets or exceeds this value.

4. Compressor Start Components: The unit does not have any
factory-installed start components. If required, install the
necessary start components as per the installation guidelines and
local electrical codes.

5. Outdoor Fan: The outdoor fan is a propeller type with a
diameter of 21-5/8 inches. It is driven by a direct variable speed
motor. Adjust the motor speed as per the desired cooling
requirements.

6. Outdoor Coil: The outdoor coil is a plate fin type with 1 row
and 21 fins per inch. Ensure that the coil is clean and free from
any debris or obstructions for efficient heat transfer.

7. Refrigerant Control: The unit uses an electric expansion
valve as the refrigerant control. No adjustment is required for
normal operation.

8. Maintenance: Regularly inspect and clean the unit to ensure
optimal performance. Refer to the user manual for detailed
maintenance instructions.

9. For more information and support, visit the manufacturer’s
website at www.trane.com or
www.americanstandardair.com.

Submittal
Split System Heat Pump
E4HL5018A1000A
NOTE: “Graphics in this document are for representation only. Actual model may differ in appearance.”
E4HL5018A-SUB-1A-EN

Outline Drawing

Model

A

B

C

D

E

F

G

H

I

E4HL5018A1000A

31.35

35.83 14.13

15.36

16.59

5.97

6.07

3.71

6.09

All dimensions are in inches

NOTE: ALL DIMENSIONS ARE REFERENCE DIMENSIONS

SOUND POWER LEVEL

Model

A-Weighted Sound Power Level [dB(A)]

63Hz*

125Hz

Full Octave Sound Power [dB] 250Hz 500Hz 1000Hz 2000Hz

E4HL5018A1000A

58

56

48

46

44

55

50

Note: Rated in accordance with AHRI Standard 270­2015 *For reference only.

4000Hz 38

8000Hz 29

2

Product Specifications

OUTDOOR UNIT (a) POWER CONNS. — V/PH/HZ (b) MIN. CIR. AMPACITY MAX. OVERCURRENT PROTECTION COMPRESSOR NO. USED — NO. STAGES VOLTS/PH/HZ R.L. AMPS (c) FACTORY INSTALLED
START COMPONENTS (d) INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) — NO. USED TYPE DRIVE — NO. SPEEDS NO. MOTORS — HP CFM @ 0.0 IN. W.G. (e) MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL — TYPE ROWS — F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT LBS. ­ R-410A (O.D. UNIT) (f) FACTORY SUPPLIED LINE SIZE — IN. O.D. GAS LINE SIZE — IN. O.D. LIQ. CHARGING SPECIFICATIONS SUBCOOLING DIMENSIONS
CRATED (IN.)
UNCRATED (IN.)
WEIGHT Shipping Net (Lbs.)

E4HL5018A1000A 208/230/1/60 21.5
35
Rotary 1-VARIABLE 208/230/1/60
15.8
NO YES NO PROPELLER 21-5/8″-1 DIRECT — VARIBLE 1-1/10 2700 850 208/230/1/60 1.1 PLATE FIN 1-21 8.18 3/8″ ELEC. EXPANSION VALVE
5 LBS, 1 OZ YES 3/4″ 3/8″
5°F HxWxD 40-1/4″×32-7/8″×18-
7/8″ 35-3/4″×31-5/8″×14-
1/8″
161 104

(a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240.
(b) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses.
(c) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current.
(d) No means no start components.
(e) Standard Air — Dry Coil — Outdoor
(f) This value is approximate. For more precise value see unit nameplate.

3

Mechanical Specification Options

General
The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 60335-2-40. Exterior is designed for outdoor application.
Casing
Unit is painted with a glossy corrosion resistant finish on all panels. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. All panels are subjected to our 500 hour salt spray test.

Refrigerant Controls
Refrigeration system controls include condenser fan, compressor drive and low pressure switches.
Compressor
The compressor features external over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise.
Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grilles and panels.
Low Ambient Cooling
As manufactured, this system has a cooling capacity to 5°F.

4

About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com

The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org.