S 4044 Shaw Extra Large Flush Mount
Product Information
The Shaw Extra Large Flush Mount (Item # S 4044) is a light
fixture that should be installed in accordance with all applicable
local installation codes. It is important to have a person familiar
with the construction and operation of the fixture, as well as the
hazards involved, to perform the installation. The fixture should
be inspected carefully upon receipt, and if any damage or defect is
found, it should not be installed. All packaging material should be
retained until installation is complete and approved.
The fixture comes with a mounting plate, fixture body, light
source, quick connector, glass shade, and screws. It requires tools
such as a Phillips screwdriver, slotted screwdriver, drill, pencil,
and hammer for installation.
Product Usage Instructions
- Carefully remove all parts from the box and place them on a
clean, soft surface. - Remove the mounting plate from the fixture body by removing the
screws. - Remove the light source from the mounting plate by removing the
screws. - Using the mounting plate as a guide, line it up with the
junction box and mark anchor positions. - Drill holes in the marked positions slightly smaller than the
anchors. Install anchors into the holes using a hammer. - Install the mounting plate to the junction box and secure it
with mounting screws and wood screws to the anchors. - Run the support cable through the hole on the back of the
mounting plate. Loosen the cable lock and install it to the end of
the support cable. Insert the other end of the cable through the
cable lock and tighten the ends with a screwdriver to secure. - Remove the quick connector from the light source.
- Wrap the quick connector ground wire around the green grounding
screw. Tighten it. - Continue the quick connector ground wire and connect it to the
supply ground wire using a wire nut. Ensure that the fixture is
grounded. - Connect the quick connector neutral wire to the supply neutral
wire using a wire nut. - Connect the quick connector hot wire to the supply hot wire
using a wire nut. Ensure that the hot and neutral connections are
not reversed. - Tuck all wire connections carefully into the junction box.
- Connect the quick connectors together, then install the light
source to the mounting plate and secure it with screws. - Install the glass shade to the fixture body and secure it with
screws. Do not over-tighten to avoid damage. - Install the fixture body to the mounting plate and secure it
with screws.
Care Instructions
Clean the fixture only with a soft dry cloth or feather duster.
Do not use abrasive or chemical agents.
ASSEMBLY INSTRUCTIONS
Diagram 2 Diagram 1
Shaw Extra Large Flush Mount
Item # S 4044
NOTICE:
This light fixture should be installed in accordance with all applicable,
local installation codes, and by a person familiar with the construction
and operation of it, as well as the hazards involved. Inspect item and
A
contents carefully. If any damage or defect is found, do not install.
Retain all packaging material until installation is complete and approved.
B
TOOLS REQUIRED (NOT INCLUDED):
C
Phillips Screwdriver
Slotted Screwdriver
Drill
Pencil
Hammer
D
E1
1. Carefully remove all parts from the box. Place on a clean, soft surface.
F
2. Remove mounting plate (C) from fixture body (L) by removing
E2
screws (K).
3. Remove light source (H) from mounting plate (C) by removing
screws (I). H
4. Using mounting plate (C) as a guide, line up with the junction box and
mark anchor positions.
I
5. Using a drill bit slightly smaller than the anchor, drill holes in the
J
marked positions. Install anchors (B) into the holes using hammer.
6. Install mounting plate (C) to the junction box and secure with
K mounting screws (D), then secure wood screws (F) to anchors (B).
7. Run support cable through hole on back of mounting plate (C).
L
Loosen cable lock and install to end of support cable. Insert other end
of cable through the cable lock and tighten ends with a screwdriver to
secure. (see diagram 1)
8 Remove quick connector (E1) from light source.
9. Wrap quick connector ground wire (bare copper) around the green
M
grounding screw (see diagram 2). Tighten. Continue quick connector
ground wire and connect to supply ground wire (usually green or bare
copper) using wire nut (A).
NOTE: It is imperative that the fixture is grounded.
M
LI ST ED
US
ASSEMBLY INSTRUCTIONS
Diagram 2 Diagram 1
Shaw Extra Large Flush Mount
Item # S 4044
NOTICE:
This light fixture should be installed in accordance with all applicable,
local installation codes, and by a person familiar with the construction
and operation of it, as well as the hazards involved. Inspect item and
A
contents carefully. If any damage or defect is found, do not install.
Retain all packaging material until installation is complete and approved.
B
10. Connect quick connector neutral wire (white) to the supply neutral
C
wire (usually white) using wire nut (A).
11. Connect quick connector hot wire (black) to the supply hot
D
wire (usually black) using wire nut (A).
E1
CAUTION: Do not reverse the hot and neutral connections.
F
12. Make sure all wire connections are tight, then carefully tuck into the
E2
junction box.
13. Connect quick connectors (E1 & E2) together, then install light
source (H) to mounting plate (C) and secure with screws (I).
H
14. Install glass shade (M) to fixture body (L) and secure with screws (J).
NOTE: Do not over-tighten otherwise shade could become damaged.
I
15. Install fixture body (L) to mounting plate (C) and secure with
screws (K). J
K
Care Instructions: Clean only with a soft dry cloth or feather duster. Do
not use abrasive or chemical agents.
L
M
M
LI ST ED
US












