VS133 AI ToF People Counting Sensor
Product Information: AI ToF People Counting Sensor – VS133
Packing List:
- AI ToF People Counting Sensor (VS133)
- Quick Start Guide
- Power Adapter
- Ethernet Cable
- Mounting Screws
Hardware Introduction:
The AI ToF People Counting Sensor (VS133) features the following
components:
- RGB LED Indicator
- Reset Button
- Multi-Interface (Ethernet Interface – PoE)
- Wi-Fi Button (LoRaWANs Version Only)
- DC Interface
| Function | Action | LED Indicator |
|---|---|---|
| Turn ON/OFF Wi-Fi (LoRaWANs Version Only) | Press and hold the button for more than 3 seconds. | Enable/Disable: Blue light blinks for 3 seconds Wi-Fi ON: Blue light blinks constantly Wi-Fi OFF: Green light blinks constantly |
| Reset to Factory Default | Press and hold the button for more than 10 seconds. | Green light blinks until the reset process is completed. |
Power Supply:
The VS133-868M/915M/470M version is powered by an adapter
(12VDC, 2A). The PoE version (VS133-P) is powered by 802.3 at
standard PoE.
Choose one of the following methods to power up the device:
- Powered by PoE Switch: Connect the PoE Switch to the device
using an Ethernet Cable. - Powered by Power Adapter: Connect the Power Adapter to the
device using an Ethernet Cable and PoE Injector.
Installation:
- Fix the device to the wall plugs using the provided mounting
screws. - Take the cover back to the device.
Note: The maximum installation height should be
3.5m. Refer to the user manual for recommended heights for people
counting in different areas.
Access from Web Browser:
To access the device from a web browser, refer to the user
manual for detailed instructions.
FCC Statement:
This device complies with part 15 of the FCC Rules. It may not
cause harmful interference and must accept any interference
received, including interference that may cause undesired
operation. To ensure compliance, please follow these
guidelines:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver. - Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for
help.
This equipment should be installed and operated with a minimum
distance of 20cm between the radiator and your body. It must not be
co-located or operated in conjunction with any other antenna or
transmitter.
For any software downloads or additional information, visit
https://www.milesight-iot.com/documents-download/
Milesight IoT Co., Ltd.
Building C09, Software Park Phase III, Xiamen 361024, Fujian,
China
AI ToF People Counting Sensor
VS133
1. Packing List
1 × VS133 Device
4 × Ceiling Mounting Kits
1 × Multi-Interface (PoE Version Only)
1 × Quick Start Guide
8 × Staff Tags
1 × Warranty Card
1 × Power Adapter (LoRaWANs Version Only)
2.Hardware Introduction
3R(9HUVLRQ
RGB LED Indicator Reset Button
Multi-Interface
ToF Sensor Ethernet Interface (PoE)
/R5D:$1p9HUVLRQ
RGB LED Indicator Reset Button/Wi-Fi Button
ToF Sensor DC Interface
3. Button Patterns
Function
Action
LED Indicator
Turn ON/OFF Wi-Fi (LoRaWANs Version Only)
Press and hold the button for more than 3 seconds.
Enable/Disable: Blue light blinks for 3 seconds Wi-Fi ON: Blue light blinks constantly Wi-Fi OFF: Green light blinks constantly
Reset to Factory Default
Press and hold the button for Green light blinks until the reset
more than 10 seconds.
process is completed
4. Power Supply
LoRaWANp Version VS133-868M/915M/470M is powered by adapter (12VDC, 2A).
PoE Version VS133-P is powered by 802.3 at standard PoE. Choose one of the following methods to power up the device:
Powered by PoE Switch
PoE Switch
3RZHUHGE3R(,QMHFWRU
Ethernet Cable
Power Adapter
Power Adapter
PoE Injector Ethernet Cable
Switch
Cloud App
Quick Start Guide
All oftware & files can be downloaded from https://www.milesight-iot.com/documents-download/
Milesight IoT Co., Ltd. www.milesight.com
Building C09, Software Park Phase III, Xiamen 361024, Fujian, China
5. Installation
,QVWDOODWLRQ6WHS 1.Ensure the thickness of ceiling is more than 30mm, then attach the mounting sticker to the ceiling and drill 4 holes with a diameter of 6mm. If the wire needs to be extended to the interior of the ceiling, a wire hole with suitable size is required to be drilled. 2.Fix the wall plugs into the ceiling holes. 3.Remove the cover on the device, and then connect all required wires and pass them through the wire hole on the device. Or break the block on the side of the device, if the wires need to protrude from the side of the device. Note: if you will use the Alarm I/O port of VS133-P, please connect the Multi-interface to the device
4.Fix the device to the wall plugs via mounting screws. 5.Take the cover back to device.
Recommended Height
The maximum installation height should be 3.5m. Monitored areas for people counting at different heights:
-RWXEPPEXMSR,IMKLXQ
2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4 3.5
1SRMXSVIH%VIEQ
5.75 × 4.20 5.98 × 4.36 6.21 × 4.53 6.44 × 4.70 6.67 × 4.87 6.90 × 5.03 7.13 × 5.20 7.36 × 5.37 7.59 × 5.54 7.82 × 5.71 8.05 × 5.87
(IXIGXMSR%VIEQ
1.84 × 1.34 2.07 × 1.51 2.30 × 1.68 2.53 × 1.85 2.76 × 2.01 2.99 × 2.18 3.22 × 2.35 3.45 × 2.52 3.68 × 2.69 3.91 × 2.85 4.14 × 3.02
-RWXEPPEXMSR2SXI
1EOIWYVIXLIHIXIGXMSRTEVXSJWIRWSVMWJEGMRKWXVEMKLXHS[RERHMRPMRI [MXLXLIGIMPMRK %ZSMHHMVIGX-RJVEVIH0)(PMKLXMRXLIHIXIGXMSREVIE (SRSXMRWXEPPXLIWIRWSVGPSWIXSKPEWWSVQMVVSV )RWYVIXLEXXLIVIEVIRSSXLIVSFNIGXWFPSGOMRKXLI8S*PMKLX[MXLMREGQ VEHMYWSJXLIJVSRXSJXLIHIZMGI 8LSYKLXLIHIZMGIMWGSQTPMERX[MXL’PEWW-)’)2
TPIEWI (3238PSSOEXXLI8S*WIRWSVXSSGPSWIERHHMVIGXP]
6. Access from Web Browser
:7TVSZMHIWYWIVJVMIRHP][IF+9-JSVGSRJMKYVEXMSRERHYWIVWGEREGGIWWMXZME;M*M connection or Ethernet port. Users need to set the password when using the device for XLIJMVWXXMQI8LIHIJEYPXWIXXMRKWEVIEWFIPS[ ;M*M77-(4ISTPI’SYRXIVC\\\GERFIJSYRHSRXLIPEFIP
;M*M-40S6E;%2p:IVWMSR
)8,-44S):IVWMSR
,IVIEVI[E]WSJEGGIWWMRKXLI[IF+9- ;MVIPIWW1IXLSH)REFPIXLI;MVIPIWW2IX[SVO’SRRIGXMSRSR]SYVGSQTYXIVWIEVGLJSV GSVVIWTSRHMRK;M*M77-(XSGSRRIGXMXXLIRX]TIXSEGGIWWXLI[IF+9- ;MVIH1IXLSH’SRRIGXXLIHIZMGIXSGSQTYXIVZME)XLIVRIXTSVXEWWMKRXLI-4EHHVIWW SJGSQTYXIVXS\QERYEPP]XLIRX]TIXSEGGIWWXLI[IF+9-
7. FCC Statement
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and. (2) This device must accept any interference received, including interference that may cause undesired operation.
2SXIThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
–Reorient or relocate the receiving antenna. –Increase the separation between the equipment and receiver. –Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. –Consult the dealer or an experienced radio/TV technician for help.
*”6EHMEXMSR)TSWYVI7XEXIQIRX
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.