4350W Chiller Unit
Product Information
The Pride on the Line Buddy Chiller Unit is an accessory
designed for use with Class I Portable Whirlpool Baths. It is used
to chill the water in the bath to provide a refreshing and cooling
experience during use. The Chiller Unit is equipped with various
components such as a water pump, fan, water sensor, defrost sensor,
and switches for water flow, low pressure, and high pressure. It
operates on a power supply of 12V DC.
Contents of the Box
- Pride on the Line Buddy Chiller Unit
Technical Parameters
- Power Supply: 12V DC
Main Component Composition
- Water pump
- Fan
- Water sensor
- Defrost sensor
- Water flow switch
- Low pressure switch
- High pressure switch
Set Up Requirements
- The Buddy Chiller Unit should be kept at least 3.0 meters away
from any socket-outlet and the external rim of the bath. - Ensure sufficient space and ventilation around the Chiller
Unit. The air inlet should be at least 30cm away from any surface,
and the air outlet should be at least 40cm away from any
surface. - Avoid mounting the Chiller Unit above the bath to prevent
electrical components from falling into the water.
Product Usage Instructions
Important Safety Information & Cautions
General:
- The Buddy Chiller Unit is not suitable for use by children.
Keep it out of their reach to prevent accidents or damage. - People with reduced physical, sensory, or mental capabilities,
or those lacking experience and product knowledge, should not use
or maintain the Buddy Chiller Unit without supervision and
instruction from a competent adult. - When used in a commercial setting, qualified personnel should
supervise the operation of the Buddy Chiller Unit.
Electrical:
- Only connect the Buddy Chiller Unit directly to an earthed
socket-outlet of fixed wiring. - Make sure the voltage supplied to the unit matches the voltage
indicated on the nameplate. - Use a residual current device (RCD) with a rated residual
operating current not exceeding 30 mA to supply power to the
appliance. - Regularly check the power and cable connections. If the supply
cord is damaged, have it replaced by the manufacturer or a
qualified person to avoid hazards. - If any abnormalities or burning scent is detected in the
electrical components, immediately seek repair from the
manufacturer or a qualified person.
Setup & Storage:
- Keep the external rim of the ice bath at least 3.0 meters away
from any socket-outlet. - The Buddy Chiller Unit should be kept at least 3.0 meters away
from the external rim of the bath. - Ensure sufficient space and ventilation around the Chiller
Unit. The air inlet should be at least 30cm away from any surface,
and the air outlet should be at least 40cm away from any
surface. - Avoid mounting the Chiller Unit above the bath to prevent
electrical components from falling into the water.
USER MANUAL
PRIDE ON THE LINE
BRING YOUR A GAME
CONTENTS
00
Thank you for purchasing a Pride on the Line Buddy Chiller Unit. Please read through the entire User Manual carefully prior to use to ensure correct operation of system.
Please keep this User Manual for future reference.
01 Important Safety Information & Cautions 02 Parts Included in Box 03 Technical Parameters 04 Main Component Composition 05 Set Up Requirements 06 Chiller Unit Set Up 07 Chiller Unit Operation 08 Menu Codes & Functions 09 Trouble Shooting 10 Post-Sales Services
IMPORTANT SAFETY INFORMATION & CAUTIONS
01
IMPORTANT SAFETY I N F O R M AT I O N & CAUTIONS
1 GENERAL
The Buddy Chiller Unit is not to be used by children. Please keep the Buddy Chiller Unit beyond the reach of children to avoid the risk of accidental injury or damage.
The Buddy Chiller Unit is not to be used or maintained by people with reduced physical, sensory or mental capabilities, or those with a lack of experience and product knowledge, unless supervision and instruction is provided by a competent adult.
The Buddy Chiller Unit is used as an accessory of Class I Portable Whirlpool Baths.
Staff supervision by qualified personnel is required when the Buddy Chiller Unit is being used and operated in a commercial setting.
2 ELECTRICAL
The Buddy Chiller Unit must only be plugged directly into an earthed socket-outlet of the fixed wiring.
The Buddy Chiller Unit is only to be connected to the voltage as indicated on the nameplate of the unit.
The appliance must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA. Ensure that your AC power supply conforms with the national wiring regulations and any additional requirements in your area.
Check the power and cable connections regularly. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Have electrical components repaired by the manufacturer, its service agent or similarly qualified persons immediately if there are any abnormalities or there is a burning scent.
Details on rating of the RCBO Overcurrent: 10A; Residual current: 30mA.
N
L
capacity
comp.
water pump
FAN
E
power ~
12v
8
43
9v
water sensor defrost sensor
transformer
water flow switch low pressure switch high pressure switch
WARNING:
ELECTRICAL PARTS MUST BE HANDLED BY PROFESSIONALS ONLY.
ILLEGAL USE OF ELECTRICITY IS STRICTLY PROHIBITED AND MAY CAUSE SERIOUS HARM TO THE OPERATOR.
IMPORTANT SAFETY INFORMATION & CAUTIONS
01
3 SETUP & STORAGE
The external rim of the ice bath shall be kept at least 3.0 m away from any socket-outlet.
The Buddy Chiller Unit must also be kept at least 3.0 m away from the external rim of the bath.
Please ensure that the Buddy Chiller Unit is located in an area with sufficient space and ventilation. The distance of the air inlet should be no less than 30cm away from the nearest surface and the distance of air outlet should be no less than 40cm away from the nearest surface.
Do not mount the Buddy Chiller Unit above the bath. Parts incorporating electrical components must be located or fixed so that they cannot fall into the bath.
If the Buddy Chiller Unit is installed on a wall bracket, please ensure that the bracket is checked regularly to identify any deterioration caused by aging or wear. Please ensure that the Chiller is mounted away from passers by.
To ensure that the Buddy Chiller Unit is operated safely at all times, please keep the water Chiller Unit away from animals and aquatic environments such as swimming pools, fish tanks and aquariums.
The Buddy Chiller Unit is not intended to be used with a bath which has a capacity greater than 1000 L.
The Buddy Chiller Unit is not intended for use at temperatures lower than 5 Degrees Celsius as this would put the user at risk of hypothermia.
It is the owner’s responsibility to display all necessary safety notices as may be required by law.
Particular care must be taken on all surfaces on or near the baths. Pride on the Line Pty Ltd will not accept any liability for injury or death from slips or falls in or around the bath.
Please ensure that your Buddy Chiller Unit is positioned away from direct exposure to the elements. Placing your unit in conditions where it is exposed to harsh sunlight, rain, dirt, debris, salt or similar may result in damage which is not covered under warranty.
The Buddy Chiller Unit must remain upright at all times. Never lay the unit on it side as this will damage the internal components.
4 CLEANLINESS & SANITISATION
Maximum and minimum water operating temperatures 5°C to 30°C
You must contact local Authorities in relation to pool fencing, sanitisation and other mandatory regulations that must be adhered to. These matters are not the responsibility of Pride on the Line Pty Ltd.
Chlorine and salt water may be used at normal concentrations and not beyond the levels recommended for normal use in swimming pools.
Bromine is never to be used as it is highly corrosive and can cause skin and eye irritation.
5 MAINTENANCE
To ensure that pipes and hoses are not clogged, if in use, please clean the filter regularly. Depending on the frequency of use, this should occur approximately every 1-2 months.
Check the status of the pump regularly to avoid having the unit operate without water.
Please use the supplied hoses or similar rigid hoses or pipes for the inlet/outlet to avoid blockages which can affect the cooling capacity of the machine.
Check the water circulation system regularly to ensure the normal operation of water flow.
Please clean the Buddy Chiller Unit regularly (usually 1-2 monthly) to ensure that the machine is well ventilated and to prevent dust from sticking to the condenser and causing poor heat dissipation.
If the machine is likely to be unused for a long period of time, please turn off the power and drain the water. Place the Chiller in a clean, ventilated and dry place to ensure that it is ready for future use.
PARTS INCLUDED IN BOX
02
COMPONENTS YOU WILL FIND INCLUDED IN BOX
2 x 25mm screw-in poly cam-lock fittings (1 x male + 1 x female BSP)
2 x 32mm screw-in poly cam-lock fittings (1 x male + 1 x female BSP)
1 x ball valve complete with a 32mm poly BSP nipple pre-attached on one end
1 x 25mm poly cam-lock cap 1 x 32mm poly cam-lock cap 1 x roll plumbers tape
1 x 25mm hose with poly cam-lock ends
1 x 32mm hose with poly cam-lock ends
TECHNICAL PA R A M E T E R S
03
410
715 485 680
BUDDY SPECIFICATIONS
Lowest Temperature Cooling Capacity Power Supply Pump Rate Evaporator Material RCD Power Plug Refrigerant Quantity Temperature Precision Unit Size Connection Size Net Weight
5°C No Heating 4350W 220 240V/50Hz 90W/220V Pure Titanium Evaporator Built-in RCD Electrical Safety Device Type Y Supply Cord 2.5kg (R410A) ±1°C 715 x 485 x 680mm In: 32mm/Out 25mm 60kg
MAIN COMPONENT COMPOSITION
04
1 Product Model 2 Water OUTLET 3 Water INLET 4 Wheels 5 Main Chassis 6 Air Inlet
7 Standard Control Touch Screen
8 Top Handles
9
Information Panel Including Model, Voltage & Serial Number
10 Air OUTLET 11 Condenser
12 Evaporator Valve
13 Main Power In 14 Safety Test Button
FRONT VIEW
7
5
1 6
4
BACK VIEW
13 8
14 9
LEFT SIDE VIEW
2 10
3
RIGHT SIDE VIEW
2 11
3 12
SET UP REQUIREMENTS
05
1 POSITION UNIT
The water Buddy Chiller Unit should be installed in a flat position and kept evenly balanced. Avoid sunlight or direct water spray. Ensure that the air inlet fan is positioned at least 30cm from the closest surface and that the air outlet is positioned at least 40cm from the closest surface.
22 LOCK WHEELS
The water chiller base is equipped with 4 universal wheels, which can move or be easily fixed. Once you have positioned the Buddy Chiller Unit in the desired location, press down on the black lever located above the wheel itself until you feel resistance. Increase the pressure of the push until you hear a click and the lever is not able to be pressed down any further.
3 CHECK HOSES
Two flexible hoses separately connect the inlet and outlet of the Buddy Chiller Unit to your bath. Before connecting the power, please check all pipes to ensure that there are no leaks, blockages or breaks.
WARNING:
Check the condenser regularly for heat dissipation to ensure efficient use. You may notice a considerable amount of condensation which may require the use of a drip tray.
06
SETTING UP THE CHILLER UNIT
AND BATH
Following are the 3 steps to setting up your Buddy Chiller Unit and bath. It is important to do the steps in the order shown, making sure the hoses are connected BEFORE the bath is filled, as the bath may need to be tilted when connecting the ball valve at the base of the bath.
CHILLER UNIT SET UP
1 CONNECT THE HOSES
Screw the applicable 25mm fitting into the “OUT” port on the Buddy Chiller Unit and the other into the top port of the ice bath.
Screw the applicable 32mm fitting into the “IN” port on the Buddy Chiller Unit.
Screw the ball valve into the bottom port of the ice bath.
Screw the second 32mm fitting into the end of the ball valve.
Connect one end of the 25mm hose to the 25mm fitting on the Buddy Chiller Unit via the cam-lock fitting and connect the other end to the 25mm fitting on the ice bath via the cam-lock fitting.
Connect one end of the 32mm hose to the 32mm fitting on the Buddy Chiller Unit via the cam-lock fitting and connect the other end to the 25mm fitting on the ice bath via the cam-lock fitting.
TIP:
Use plumbing tape around all threads including the inlet and outlet ports of the Chiller Unit and ice bath.
2 FILL THE BATH
The bath should NOT be filled before the hoses have been connected as the bath may need to be tilted slightly when connecting the ball valve at the base of the bath.
For the Recovery Bath Compact and Duo Models, ensure the bath is filled to a level ABOVE the inlet hole at the top of the bath. For the Ice Bath Solo, Twin and Trio, the water level will be below the inlet hole (see diagram on adjacent page).
3 POWER UP THE CHILLER UNIT
Confirm that the safety switch at the rear of the Buddy Chiller Unit is in the “ON” position. Connect the power cable at the rear of the Buddy Chiller Unit to a compatible, allocated wall socket. Switch the power on at the wall socket. The Buddy Chiller Unit is now operating and the display screen is illuminated.
MINIMUM WATER LEVEL FOR RECOVERY BATH COMPACT AND DUO
REQUIRED WATER LEVEL FOR ICE BATH
SOLO, TWIN AND TRIO
BATH
CHILLER UNIT OPERATION
07
Following the Buddy Chiller Unit setup, you can now set the machine to operate to your specifications.
NOTE: Controller boot sequence The touch screen buttons need to be pressed for 1.5 seconds to activate a command.
cooling mode green light
constant temperature
water pump switch
water temperature
temperature setting
POWER SUPPLY: 220-240 V/50Hz
DISPLAY RANGE: 2.0~45°C Celsius 35~95°F
LOWEST TEMPERATURE: 5°C
FACTORY SETTING: 10°C (50°F)
up key SET
down key
power switch
IMPORTANT:
Before activating the Buddy Chiller Unit, ensure that the ball valve is in the flow position which is indicated by the valve being parallel to the hose. If the ball valve is not in the flow position, water cannot circulate through the system.
ACTIVATING THE BUDDY CHILLER UNIT
Press the ON/OFF button on the operating screen for 1.5
1 seconds until the button appears backlit by a round red circle. The Buddy Chiller Unit is now operational.
To activate the pump, press the PUMP button for 1.5 seconds
2 until a second audible beep is heard. The button will now be
backlit in red and you will also notice that the “COLD” light at the top left of the operating screen is backlit and flashing green. You will hear the water circulating through the system and will also be able to see and feel water flowing into the ice bath via the inlet port at the top of the ice bath.
To set the desired water temperature, press the “SET” button for
3 1.5 seconds until a second audible beep is heard. You will notice
that the top number flashes red and the word “SET” appears in orange below it. This allows you to set the desired temperature whilst the temperature value is flashing. Press arrow up or arrow down to increase or decrease your desired water temperature in increments of 0.1 Degrees Celsius.
Once you have set your desired temperature, the display screen
4 will flash for a few seconds before returning to the home screen. At this point, if you don’t wish to alter any of the other menu settings, do not press any other buttons. The Actual Water Temperature will be shown on the top in red and the Set Water Temperature at the bottom in orange.
The Buddy Chiller Unit is now preparing to cool and will activate
5 within 3 minutes. At the 3 minute mark you will hear the
condenser begin operating which indicates that the refrigeration component is now operational.
To change any of the menu setting shown on the Menu Code
6 table of this User Manual, press the “SET” button for 6 seconds until a second audible beep is heard.
The system password now has to be entered and has been
7 preset to 95. Press the arrow up or arrow down buttons until you reach this number. When the number is reached and appears on the screen, press the “SET” button and the first menu option “F1” will appear.
Use the up and down arrows to alter the values and the screen
8 will flash for a few seconds before returning to the home screen, automatically saving your setting. Alternatively, you can quick press the “SET” button to move to the next menu option.
9 When you are ready to turn off the Buddy Chiller Unit, press the pump button for 1.5 seconds to power off the pump, followed by the ON/OFF button. The pump button will no longer be backlit and the temperature setting on the screen will read `OFF’.
MENU CODES & FUNCTIONS
08
MENU CODES
Code F1 F2 F3 F4 F5 heating F6 heating F7 heating F8 heating F9 FA
Function Temperature return difference Temperature modification Compressor time delay Menu password Not Applicable Not Applicable Defrosting time Defrosting cycle Fahrenheit Celsius conversion Single cold mode
Range 0.3 – 8°C (1 – 15°F) -5 – 5°C (1 – 15°F) 1-7 min 1 – 255
Default Setting 2 0 3 95
1 30 min
5
10 180 min
30
00 – 01
0=°C
No setting alterations required
Please note:
1
For Fahrenheit and Degree Celsius conversion, 00 refers to Degree Celsius and 01 refers to Fahrenheit .
2
For reference, the Buddy Chiller Unit is only suitable for use in COLD MODE.
Temperature view: The top digital display indicates the actual
3
temperature of the ice bath. The bottom digital display indicates
the set temperature.
TROUBLE SHOOTING
09 An open circuit or short circuit fault of the water E 1 temperature sensor, which limits the temperature control work.
Have the manufacturer, its service agent or similarly qualified persons check if the port where the sensor wire is connected to the controller is loose? If so, it may need to be tightened.
The defrosting sensor has an open circuit or a short circuit
E2 fault.
This error is only applicable for heating units and does not relate to the Buddy Chiller Unit.
Water Flow Failure.
E3 This error occurs when air is trapped in the system. The Buddy Chiller Unit will automatically attempt to clear the air to restore normal operation. If the air is not cleared after three cycles, power off the unit and disconnect the hose from the inlet port of the ice bath to release the water. Reconnect the hose and power up the unit to resume normal operation.
Low pressure fault of the refrigeration system, which limits
E4 the temperature control work.
This error is generally related to other models with a capacity greater than 5HP. Please contact customer support should this error occur in your Buddy Chiller Unit.
High pressure fault of the refrigeration system, which limits
E5 the temperature control work.
This error is generally related to other models with a capacity greater than 5HP. Please contact customer support should this error occur in your Buddy Chiller Unit.
EE Communication failure caused by communication line or communication chip damage. Have the manufacturer, its service agent or similarly qualified persons unplug the communication line waterproof connector, re-docking, check whether the communication terminal on the control board is loose or off, and re-tighten.
The temperature sensor temperature is equal to or lower than
EL 2ºC (35ºF) and the ultra low temperature alarm is activated.
The function of the temperature control is limited. Power off the Buddy Chiller Unit immediately and then power on again after at least half an hour. Note: this error is unlikely to occur as the operating temperature of the unit is above 5 Degrees Celsius.
The temperature sensor temperature is equal to 42ºC temperature
EH (95ºF) and the ultra high alarm is triggered. The function of the
temperature control is limited. This error does not apply to the Buddy Chiller Unit as it has a cooling function only.
10
P O S T- S A L E S SERVICES
1 One year warranty excluding consumer goods.
2
Damage caused by improper operation is not covered by the warranty.
Pride on the Line Pty Ltd will not be liable for any
3 consequential, indirect, or incidental damages of any kind, including lost revenue, lost profits, or other losses in connection with the product.
4
Please do not disassemble the machine without consultation with the support team first.
11
RECOVERY ICE BATHS
PRIDE ON THE LINE ICE BATH RANGE
COMPACT DUO
PORTABLE RECOVERY ICE BATHS
SOLO
TWIN
TRIO
NATURAL RANGE ICE BATHS
STORM
SNOW
SAND
MARBLE
If you would like more information about Pride on the Line, or how we can provide a customised solution to meet
your needs contact us at:
10b Hender Avenue Magill SA 5072 1300 305 006
[email protected]
facebook.com/prideontheline instagram.com/prideontheline
@prideontheline Pride on the Line