Lunapro2250ctw 250w Led Tunable Profile Spot Zoom User Manual

LUNAPRO2250CTW 250W LED Tunable Profile Spot Zoom

Product Information

The LUNAPRO2250 CTW is a 250W LED Tunable Profile Spot Zoom. It
is a powerful and versatile device that offers various features for
lighting applications.

The product includes the following components:

  • Yoke
  • Shutters
  • Gobo holder slot
  • Iris slot
  • Yoke locking knob
  • Color frame
  • Focus knob
  • Zoom knob
  • Color frame clip
  • LCD display
  • On/off switch
  • Handle
  • Rotary button
  • Power in/out
  • Fuse
  • DMX in/out
  • DMX signal indicator
  • Power indicator
  • Menu button
  • Up button
  • Down button
  • Enter button

Product Usage Instructions

Safety Instructions

Please read the following safety instructions before using the
LUNAPRO2250 CTW:

  • Be careful with your operations to avoid electric shock. Do not
    touch the wires when there is a dangerous voltage.
  • Avoid looking directly into the light source and wear
    protective glasses and other personal protective equipment (PPE)
    when working on or near the fixture.
  • Ensure proper voltage connection according to the
    specifications in the manual or on the product’s specification
    label. Ground the product during usage.
  • Always unplug the mains lead before opening the housing.
  • Regularly check the fixture and power cord for any damage.
    Replace the fuse with another of the same type and rating.
  • Read the user manual carefully for operating safety precautions
    and pay attention to warning signs, methods, and equipment.
  • Wait for a cool-down period of at least 10 minutes before
    handling or transporting the device as certain parts of the housing
    can become hot during operation.
  • Qualified personnel should be involved in the installation,
    operation, and maintenance of the device.
  • Consider this manual as part of the total product and keep it
    for the entire service life. Pass it on to every further owner or
    user of the product.

Installation

Before installing the fixture, read the “Safety Information”
section in the manual. The LUNAPRO2250 CTW is designed for indoor
use only and should be placed in a dry location with adequate
ventilation. Ensure that none of the ventilation slots are
blocked.

To fasten the fixture to a secure structure or surface:

  1. Do not place the fixture on a surface where it can be easily
    moved or fall over.
  2. If the fixture is installed in a location where it may cause
    injury or damage if it falls, use a securely anchored safety cable
    along with the primary fastening method.
  3. The fixture can be fastened to a hard, fixed, flat surface at
    any angle. Ensure that the surface and all fasteners used can
    support at least 10 times the weight of all fixtures and equipment
    to be installed on it.

LUNAPRO2250 CTW
250W LED Tunable Profile Spot Zoom
USER MANUAL

Table of contents
Caution!…………………………………………………………………………………………………… 3 Introduction …………………………………………………………………………………………….. 3 Safety instructions……………………………………………………………………………………. 3 Overview …………………………………………………………………………………………………. 3 Installation ………………………………………………………………………………………………. 5
Read `Safety information’ before installing the fixture…………………………………………………………….. 5 Fastening the fixture to a flat surface ……………………………………………………………………………………. 5 Mounting the fixture on a truss …………………………………………………………………………………………….. 5 Securing with a safety cable ………………………………………………………………………………………………… 6 DMX-512 connection/connection between fixtures ……………………………………………………………….. 6 Power connection……………………………………………………………………………………………………………….. 7 Operation ………………………………………………………………………………………………… 7 Control Menu Map ………………………………………………………………………………………………………………. 7 Control menu ……………………………………………………………………………………………………………………… 8 Main Menu …………………………………………………………………………………………………………………………. 9 Addressing …………………………………………………………………………………………………………………………. 9 Universal DMX Control ……………………………………………………………………………………………………….10 RDM control ………………………………………………………………………………………………………………………10 Rotary Knob function………………………………………………………………………………………………………….10 Set dimmer curves……………………………………………………………………………………………………………..11 Zoom ……………………………………………………………………………………………………………………………….. 12 DMX Protocol ………………………………………………………………………………………… 12 Fixture Cleaning …………………………………………………………………………………….. 12 Fuse Replacement …………………………………………………………………………………. 13 Troubleshooting …………………………………………………………………………………….. 13 The fixture does not work, no light ……………………………………………………………………………………… 13 Technical specifications …………………………………………………………………………. 13

Caution!
Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching the wires!
Avoid looking directly into the light source! Wear protective glasses and other PPE (personal protective equipment) when working on or near the fixture.
Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.Make sure it is grounded when using it! Unplug mains lead before opening the housing! Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the powercord from time to time. Make sure to replace the fuse with another of the same type and rating.
For your own safety, please read this user manual carefully before you initial start-up. Follow operating safety precautions and pay attention to warning signs methods and equipment on the user manual.
Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot during operation. After use, wait for a cool-down period of at least 10 minutes before handling or transporting the device.
Indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. IP 20 rating. The ambient temperature must always be between -5° C and +45° C.
Every person involved with the installation, operation and maintenance of this device has to – be qualified – follow the instructions of this manual – consider this manual to be part of the total product – keep this manual for the entire service life of the product – pass this manual on to every further owner or user of the product – download the latest version of the user manual from the Internet
Introduction
Thank you for having chosen LUNAPRO2250CTW. You will see you acquired a powerful and versatile de-vice. Unpack your item. Before you initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device.
Safety instructions
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. Always disconnect from the mains, when the device is not in use or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by authorized dealers.
Overview

3

V1.47

Yoke Shutters Gobo holder slot Iris slot

Yoke locking knob

Color frame

Focus knob Zoom knob Color frame clip LCD display

On/off switch

Handle
Rotary button

Power Power

in

out

Fuse

Dmx in Dmx out

Dmx signal indicator Power indicator

LCD display

Menu button

Up button
4

Down button

Enter button

V1.47

Installation
Read `Safety information’ before installing the fixture. The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation. Ensure that none of the fixture’s ventilation slots are blocked.
Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
Fastening the fixture to a flat surface The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure that the surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment to be installed on it.
Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
Mounting the fixture on a truss The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.
To clamp the fixture to a truss: 1. Check that the rigging structure can support at least 10 times the weight of all fixtures and equipment
to be installed on it. 2. Block access under the work area. 3. Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting
bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting bracket legs and be fastened with a self-locking nut. 4. Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp securely. 5. Secure the fixture with a safety cable as directed below.

5

V1.47

Securing with a safety cable Secure the fixture with a safety cable (or other secondary attachment) that is approved for the weight of the fixture so that the safety cable will hold the fixture if a primary attachment fails.
Loop the safety cable through the eyebolt in the back of the fixture and around a secure anchoring point. Do not loop the safety cable around the fixture’s mounting bracket only, as this will leave the fixture unsecured if it separates from the bracket.
DMX-512 connection/connection between fixtures

Occupation of the XLR-connection: DMX OUT
1. Group 2. Signal (-) 3. Signal (+)

DMX IN
1. Group 2. Signal (-) 3. Signal (+)

If you are using controllers with this occupation, you can connect the DMX-output of the controller directly with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter-cables.

Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always connect one output with the input of the next fixture until all fixtures are connected.

DMX-512 connection with DMX terminator:
For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3, which is then plugged into the output XLR socket of the last fixture in the chain.

Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 re-

6

V1.47

sistor between Signal (­) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.

Power connection Power Requirements The LUNAPRO2250CTW zoom luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The lu-minaire contains an auto-ranging power supply.

Power linking between fixtures: The fixture with powercon in and out socket. Connect the power out to the power in socket in the next fixture till all are connected.
Caution: maximum power linking – 6 units.

Connection with the mains: Connect the device to the mains with the enclosed power supply cable.

The occupation of the connection cables as below:

Cable color Brown Blue Yellow/green

Connection Live Neutral Earth(Ground)

International L N

Operation
The LUNAPRO2250CTW zoom can operate in three different modes. In each mode you can run the fixture as a stand alone fixture or in a master/slave confiugration. This next section will detail the differences in the operating modes.

Control Menu Map Default setting in bold.

MAIN MENU

LEVEL 1

DMX

001-512

DMX

Mode

Auto

Maunal

Curve

Dimmer

Mode

LEVEL 3

LEVEL 3

FUNCTION INSTRUCTION

1/2/3CH

DMX address setting DMX channel mode

Program 001-004

Preset programs

Speed

001-009

Programs speed

Warm

000-255

Warm white dimmer 0-100%

Cold

000-255

Cold white dimmer 0-100%

0.3-3.0

Dimmer curves adjustment

Standard

Dimmer mode, Standard

Stage

Dimmer mode, Stage

TV

Dimmer mode, TV

Architecture

Dimmer mode, Architecture

Theatre

Dimmer mode, Theatre

Studio Custom

Studio power mode, silent

Fade in (150 ms~2230 ms)

Custom dimmer curve

7

V1.47

Advance
Reset Reverse

Authorization

On/Off

Signal Priority

DMX

Signal Hold

On/Off

RDM

On/Off

Screen Timeout

30S Never

Screen Brightness 25-100%

1.20KHz

1.60KHz

Dimming Freq

2.40KHz 4.00KHz

6.00KHz

20.00KHz

Yes/No

Yes/No

Fade out (150 ms~2230 ms)
Advanced settings/calibration(Only qualified technicians should perform this function. Inqure your local dealer for password.) Signal priority setting Run if signal cut RDM function on/off Display shut off time Display brightness
Dimmer frequency setting
System reset Display reverse 180 degree

Control menu The information menu will appear after the fixture is switched on. In this menu, the following status is dis-
played:

8

V1.47

Main Menu Press the MENU button to enter the Main Menu interface.
Menu

DMX

Mode

Dimmer

Advance

Addressing All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture responds to the correct control signals. This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller. The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device.
You can set the same starting address for all fixtures or a group of fixtures, or make different address for each fixture individually.
If you set the same address, all the units will start to listen to the same control signal from the same channel number. In other words, changing the settings of one channel will affect all the fixtures simultaneously.

If you set a different address, each unit will start to listen to the channel number you have set, based on the quantity of control channels of the unit. That means changing the settings of one channel will affect only the selected fixture.
In the case of the LUNAPRO2250CTW zoom, which is 1/2/3 channels fixture. If you set, for example, the address in the 1 channel mode to channel 2, the device will use the channel 2 for control.
Note: After switching on, the device will automatically detect whether DMX 512 data is received or not. If there is data received at the DMX input, you will see the DMX indicator light in green.

9

V1.47

Universal DMX Control This function allows you to use a universal DMX-512 controller to control the dimmer and strobe. A DMX controller allows you to create unique programs tailored to your individual needs.
RDM control The LUNAPRO2250CTW can communicate using RDM (Remote Device Management) in accordance with ESTA’s American National Standard E1.20-2006: Entertainment Technology RDM Remote Device Man-agement Over DMX512 Networks.
RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open standard for DMX512 device configuration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to and receive messages from specific fixtures.
With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful when the device is installed in a remote area.
Each LUNAPRO2250CTW has a factory set RDM UID (unique identification number). Note: Before operation, enable RDM function in Advanced settings.
Menu

DMX

Mode

Dimmer

Advance

Rotary Knob function
The knob in the rear panel of the LUNAPRO2250CTW act as multi function. Including rotary control of dimmer, up/down/enter function function.
Dimmer function: 1. Press the MENU button to enter the main menu. 2. Press the UP or DOWN button to select Mode menu and press ENTER. 3. Press DOWN menu and select Manual sub menu. 4. Press ENTER and select Brightness in third menu. 5. Rotate the rotary knob to control the dimmer(right stop = maximum output, left stop = zero output), or
strobe(right stop = maximum strobe, left stop = no strobe). Note: Rotary dimmer function works in information Menu and Mode-Manual menu.

Up, Down, Enter function: The knob can also act as up, down and enter function. 1. Press the MENU button to enter the main menu interface.

10

V1.47

2. Right rotation = Down, left rotation = Up, press = Enter function.

Set dimmer curves This function allows you to select preset dimmer curves as well as custom dimmer curves.

Menu
DMX

Mode

Dimmer

Advance

Menu>Dimmer Curve 1.0

Mode Standard
Stage TV
Architecture Theatre

To set preset dimmer curves: 1. Press the MENU button to enter the main menu. 2. Press the UP or DOWN button to select Dimmer menu and press ENTER. 3. Press DOWN menu and select Mode sub menu. 4. Select disired dimmer mode. Custom dimmer curves: 1. Press the MENU button to enter the main menu. 2. Press the UP or DOWN button to select Dimmer menu and press ENTER. 3. Press DOWN menu and select Mode sub menu. 4. Press the UP or DOWN button to select Custom menu and press ENTER. 5. Adjust fade in and fade out time to customize yout dimmer curves. Time vary from 150 ms to 2230
ms.

11

V1.47

Zoom This function allows you to adjust the beam width of the fixture. Step 1: Loosen the zoom buttons on the side of the device. Step 2: Adjust the zoom by sliding the back lenshousing forward or backward. Step 3: Tighten the zoom buttons.

DMX Protocol
2 Channels Mode CH1 CH2

Function Warm white Cold white

Function Control 000-255: 0-100% warm white dimmer 000-255: 0-100% cold white dimmer

3 Channels Mode CH1 CH2 CH3

Function Dimmer Warm white Cold white

Function Control 000-255: 0-100% master dimmer 000-255: 0-100% warm white dimmer 000-255: 0-100% cold white dimmer

Fixture Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend clean-

12

V1.47

ing on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.
To clean the fixture: 1. Disconnect the fixture from power and allow it to cool for at least 10 minutes. 2. Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure
compressed air. 3. Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent
solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water. 4. Check that the fixture is dry before reapplying power.

Fuse Replacement
This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel. To replace a fuse: 1. Disconnect the fixture from power and allow it to cool for at least 10 minutes. 2. Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and
rating only.
3. Reinstall the fuseholder cap before reapplying power.

Troubleshooting
Listed below are a few common problems that you may encounter, with solutions.

The fixture does not work, no light · Check the connection of power and main fuse. Be sure the external fuse has not blown. · Measure the mains voltage on the main connector.

Technical specifications

Model Power supply: Light source: Color temperature: Color Rendition: Zoom scale: Power connection: Fuse: Maximum power linking: Signal connection: DMX channels: Control mode: Housing: Size: Package(carton): N.W.: G.W.: Enviroment:

LUNAPRO2250CTW AC100-240V, 50/60Hz 500W COB LED (250W warm white + 250W cold white) 2700K ~ 5600K tunable CRI 97, R990, TLCI 98(2700K) 18°-38° manually PowerCON in&out F5A, 250V 6 units 3-pin XLR in & out 2/3 RDM, DMX, Rotary Colour black, ABS+PC 745 x 294 x 294mm(29.3 x 11.6 x 11.6in) 790 x 350 x 360mm(31.1 x 13.8 x 14.2in) 8.7kg(19.2lb) 11.5kg(25.4lb) IP20

13

V1.47

Please note: All information is subject to change without prior notice. 05.11.2019

14

V1.47

15

V1.47

16

V1.47

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals