EU-45802-HPS Pressure Injectable Arrowg+ard Blue Plus Two-Lumen CVC
Product Information:
Product Name: EU-45802-HPS
Size: 8 2 Fr.
Lumen: Yes
Catheter Length: 20cm
Spring-Wire Guide Diameter: 0.032 inch
Contents:
- 1 Spring-Wire Guide, Nitinol, Marked: 0.032 (0.81 mm) dia. x
23-5/8 (60 cm) (Straight Soft Tip on One End – J Tip on Other) with
Arrow Advancer with ECG Mark
Additional Information:
- Licensed under US Patent No. 7,329,412.
- All components are CE 2797 unless otherwise noted.
- Fluid path components are non-pyrogenic.
- Contraindications: The Arrowg+ard Blue Plus antimicrobial
catheter is contraindicated for patients with known
hypersensitivity to chlorhexidine, silver sulfadiazine, and/or
sulfa drugs.
Product Usage Instructions:
Lumen:
The product has a lumen, which allows for fluid flow.
Priming Volume:
The priming volume for the catheter is approximately 0.73 mL for
the distal lumen (14 Ga.) and 0.75 mL for the proximal lumen (14
Ga.). Priming is done without accessories.
Gravity Flow Rate:
The gravity flow rate for the catheter is approximately 5354
mL/hr for the distal lumen (14 Ga.) and 3984 mL/hr for the proximal
lumen (14 Ga.).
MAX Pressure Injection Flow Rate:
The maximum pressure injection flow rate for the catheter is 10
mL/sec for both the distal and proximal lumens (14 Ga.). This flow
rate is determined using media of 11.8 centipoise (cP) viscosity,
with 152 cm administration set tubing.
EU Authorized Representative and Importer:
Teleflex Medical
IDA Business and Technology Park
Dublin Road, Athlone
Co. Westmeath, Ireland
Arrow International LLC Subsidiary of Teleflex
Incorporated:
3015 Carrington Mill Blvd.
Morrisville, NC 27560
USA
LBL062496 R00 (2021-10)
EU-45802-HPS
8 2 Fr.
Lumen
20cm catheter length
.032 inch dia. spring-wire guide
Pressure Injectable Arrowg+ard Blue Plus® Two-Lumen CVC
Contents:
1: Arrowg+ard Blue Plus®1 Two-Lumen Catheter: 8 Fr. (2.8 mm OD) x 20 cm, Pressure Injectable
1: Spring-Wire Guide, Nitinol, Marked: .032″ (0.81 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer with ECG Mark
1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW 1: Syringe: 5 mL Luer-Slip 1: Tissue Dilator: 9 Fr. x 10.2 cm 2: Dust Cap: Non-Vented 1: SecondSiteTM Adjustable Hub: Fastener 1: SecondSiteTM Adjustable Hub: Catheter Clamp 1: SharpsAway® II Locking Disposal Cup 1: Safety Scalpel: #11
1Licensed under US Patent No. 7,329,412.
All components are CE 2797 unless otherwise noted.
Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. www.teleflex.com/IFU Not made with natural rubber latex. Store below 25°C (77°F). Avoid excessive heat above 40°C (104°F).
Fluid path components are non-pyrogenic.
Contraindications: The Arrowg+ard Blue Plus antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs.
Lumen
Priming Volume*
(mL)
Gravity Flow Rate
(mL/hr)
MAX Pressure Injection
Flow Rate** (mL/sec)
Distal (14 Ga.)
0.73
5354
10
Proximal (14 Ga.) 0.75
3984
10
* Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height. ** Pressure injection flow rates are determined using media of 11.8 centipoise (cP) viscosity, with 152 cm administration set tubing.
EU Authorized Representative and Importer: Teleflex Medical IDA Business and Technology Park Dublin Road, Athlone Co. Westmeath, Ireland Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA
LBL062496 R00 (2021-10)
EU-45802-HPS
8 2 Fr.
Lumen
20cm catheter length
.032 inch dia. spring-wire guide
Pressure Injectable Arrowg+ard Blue Plus® Two-Lumen CVC