ASW H-T2-T3-SERIE Three Phase Hybrid Inverter
Product Information:
The ASW05kH/06kH/08kH/10kH/12kH-T2
ASW05kH/06kH/08kH/10kH/12kH-T2-O ASW08kH/10kH/12kH-T3
ASW08kH/10kH/12kH-T3-O is a three-phase hybrid inverter. It is
designed and tested to meet international safety requirements. The
inverter operates at high voltage and current and must only be
worked on by skilled and authorized electricians. The product
complies with the requirements of applicable EU directives, has
been tested by TUV, and has obtained the quality certification
mark. It also complies with the requirements of applicable
Australian standards.
Product Usage Instructions:
- Ensure to read the user manual for detailed instructions and
information about the product. - For safety purposes, it is important to observe all safety
information at all times. - Do not reconnect the PV array or battery before working on the
product to avoid danger to life due to high voltages. - Avoid touching live components in backup mode to prevent
electric shock. - Ensure batteries are not fully discharged to avoid danger to
life due to fire or explosion. - Avoid short-circuit currents to prevent burns caused by
electric arcs. - In case of a ground fault, do not touch live system components
to prevent electric shock. - Do not exceed the input voltage range equal to or higher than
the voltage rating of the product to avoid electric shock from
destruction of the measuring device due to overvoltage. - Avoid contact with hot surfaces during operation to prevent the
risk of burns. - Take caution of the weight of the product to avoid the risk of
injury. - If additional grounding or equipotential bonding is required,
ensure the product is additionally grounded at the installation
site. - Dispose of the product in accordance with the disposal
regulations for electronic waste applicable at the installation
site. - Do not touch live parts of the inverter for 10 minutes after
disconnection from the power sources to avoid danger to life due to
high voltages.
ASW05kH/06kH/08kH/10kH/12kH-T2 ASW05kH/06kH/08kH/10kH/12kH-T2-O ASW08kH/10kH/12kH-T3 ASW08kH/10kH/12kH-T3-O
Three phase hybrid inverter
Quick Installation Guide
Android
iiOoSs
1 GENERAL INFORMATION
This quick installation guide does not replace the description in the user manual. The contents of this guide may be updated or revised due to product development. The information in this guide is subject to change without notice. The latest version of this document and the manual for installation, commissioning, configuration and decommissioning are to be found in PDF format at www.solplanet.net.
2 SAFETY
2.1 Intended use The product is a transformerless hybrid inverter with 2 or 3 MPP trackers and a battery connection that feeds the direct current of the PV array into the connected battery or converts it to grid-compliant three-phase current and then feeds it into the utility grid. The product also can convert the direct current supplied by the battery into grid-compliant three-phase current. The product has a backup function that can continue to supply selected circuits with power from the battery or PV system in the event of a grid fault. The product is intended for indoor and outdoor applications. The product must only be connected with PV modules of protection class II (in accordance with IEC 61730, application class A). Do not connect any sources of energy other than PV modules to the product. The product is not equipped with an integrated transformer and therefore has no galvanic isolation. The product must not be operated with PV modules which require functional grounding of either the positive or negative PV conductors. This can cause the product to be irreparably damaged. The product may be operated with PV modules with frames that require protective earthing. All components must remain within their permitted operating ranges and their installation requirements at all times. Use the product only in accordance with the information provided in the user manual and with the locally applicable standards and directives. Any other application may cause personal injury or damage to property.
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
1
The product must only be operated in connection with an intrinsically safe lithium-ion battery approved by AISWEI. The entire battery voltage range must be completely within the permissible input voltage range of the product. The product must only be used in countries for which it is approved by AISWEI and the grid operator. The type label must be permanently attached to the product and must be in a legible condition. This document does not replace any regional, state, provincial, federal or national laws, regulations or standards that apply to the installation, electrical safety and use of the product.
2.2 Important safety instructions
The product has been designed and tested strictly according to the international safety requirements. As with all electrical or electronical devices, there are residual risks despite careful construction. To prevent personal injury and property damage and to ensure long-term operation of the product, read this section carefully and observe all safety information at all times.
DANGER
Danger to life due to high voltages of the PV array or the battery
The DC cables connected to the battery or the PV array may be live. Touching the DC conductors or the live components can cause to lethal electric shocks. If you disconnect the DC connectors from the product under load, an electric arc may occur leading to electric shock and burns. · Do not touch non-insulated cable ends. · Do not touch the DC conductors. · Do not touch any live components of the product. · Do not open the product. · Observe all safety information of the battery manufacturer. · All work on the product must only be carried out by qualified personnel who have
read and fully understood all safety information contained in this document and the user manual. · Disconnect the product from all voltage and energy sources and ensure it cannot be reconnected before working on the product. · Wear suitable personal protective equipment for all work on the product.
2
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
DANGER
Danger to life due to electric shock when touching live components in backup mode
Even if the AC breaker and the PV switch of the inverter are disconnected, the parts of the system may still be live when the battery is switched on due to backup mode. · Do not open the product. · Disconnect the product from all voltage and energy sources and ensure it can
not be reconnected before working on the product.
DANGER
Danger to life due to fire or explosion when batteries are fully discharged
A fire may occur due to incorrect charging of fully discharged batteries. This can result in death or serious injury. · Make sure that the battery is not fully discharged before commissioning the
system. · Contact the battery manufacturer for further proceedings if the battery is fully
discharged.
DANGER
Danger to life due to burns caused by electric arcs through short-circuit currents
Short-circuit currents in the battery can cause heat accumulation and electric arcs if the battery is short circuited or wrongly installed. Heat accumulation and electric arcs may result in lethal injuries due to burns. · Disconnect the battery from all voltages sources prior to performing any work
on the battery. · Only use properly insulated tools to prevent accidental electric shock or short
circuits during installation. · Observe all safety information of the battery manufacturer
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
3
DANGER
Danger to life due to electric shock when touching live system components in case of a ground fault
If a ground fault occurs, parts of the system may still be live. Touching live parts and cables may result in death or lethal injuries due to electric shock. · Disconnect the product from voltage and energy sources and ensure it cannot
be reconnected before working on the device. · Only touch the cables of the PV modules on their insulation. · Do not touch any parts of the substructure or frame of the PV array. · Do not connect PV strings with ground faults to the product.
WARNING
Danger to life due to electric shock from destruction of the measuring device due to overvoltage
Overvoltage can damage a measuring device and result in voltage being present in the enclosure of the measuring device. Touching the live enclosure of the measuring device results in death or lethal injuries due to electric shock. · Only use measuring devices with the measurement span higher than the DC
input voltage range equal to or higher than the voltage rating of the product.
CAUTION
Risk of burns due to high temperature.
Some parts of the enclosure can become hot during operation. · During operation, do not touch any parts other than the enclosure lid of the
product.
CAUTION
Risk of injury due to weight of product .
Injuries may result if the product is lifted incorrectly or dropped while being transported or mounted. · Transport and lift the product carefully. Take the weight of the product into
account. · Wear suitable personal protective equipment for all work on the product.
3
4
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
2.3 Symbols on the label
Beware of a danger zone This symbol indicates that the product must be additionally grounded if additional grounding or equipotential bonding is required at the installation site.
Beware of high voltage and operating current The inverter operates at high voltage and current. Work on the inverter must only be carried out by skilled and authorized electricians.
Beware of hot surfaces The inverter can get hot during operation. Avoid contact during operation.
WEEE designation Do not dispose of the product together with the household waste but in accordance with the disposal regulations for electronic waste applicable at the installation site.
CE marking The product complies with the requirements of the applicable EU directives.
Certification mark The product has been tested by TUV and got the quality certification mark.
RCM (Regulatory Compliance Mark) The product complies with the requirements of the applicable Australian standards.
Capacitor discharge Danger to life due to high voltages in the inverter. Do not touch live parts for 10 minutes
10mins
after disconnection from the power sources.
Observe the documentation Observe all documentation supplied with the product.
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
5
3 SYSTEM WIRING DIAGRAM
Australia
PV
CT COM L1 L2 L3 N PE
Grid
Inverter
Battery DC Breaker
The additional grounding screw hole at the lower right conner
L1 L2 L3 N
× PE
Load
AC Breaker AC Breaker
CT1
L1
CT2
Main
L2
CT3
Meter
L3
N
Grid
N-Bar
PE
PE-N Link PE-Bar
RCD
AC Breaker
Normal Loads
RCD
Don’t connect this terminal for Australian and New Zealand grid system!!!
Backup Loads
6
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
Europe
PV
CT COM L1 L2 L3 N PE
Grid
Inverter
AC Breaker
Battery DC Breaker
The additional grounding screw hole at the lower right conner
L1 L2 L3 N
× PE
Load
AC Breaker
CT1
L1
CT2
Main
L2
CT3
Meter
L3
Grid
N
PE
PE-Bar
RCD
AC Breaker
Normal Loads
RCD
Backup Loads
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
7
4 EU DECLARATION OF CONFORMITY
Within the scope of the EU directives Radio Equipment Directive 2014/53/EU (L 153/62-106. May 22. 2014) (RED) Restriction of the use of certain hazardous substances 2011/65/EU (L 174/88, June 8, 2011) and 2015/863/EU (L 137/10, March 31,2015) (RoHS) AISWEI Technology Co., Ltd. confirms herewith that the products described in this document are in compliance with the fundamental requirements and other relevant provisions of the above mentioned directives. The entire EU Declaration of Conformity can be found at www.solplanet.net.
8
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
5 OVERVIEW
1
2
3
4
BATTERY ON
OFF
PV1
PV2
PV3
COM0
5
6
GRID LOAD
8
Object
1 2 3 4 5 6 7 8
7
Description
Battery Port
LED DC-switch PV Input
Ai-Dongle Communication ports AC connector EPS connector Additional grounding screw
6 SCOPE OF DELIVERY
Wall Bracket ×1
DC connector ×3/4 ACconnector×1 EPSconnector×1
Ai-Dongle ×1
Inverter×1
External CT ×3
Fastener package ×1
Communication terminal package ×1
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
Document ×1
9
7 MOUNTING ENVIRONMENT
×
×
×
75°
×
××
×
+60
-25
IP66 4K4H
100%
max.4000m
500mm
500mm
500mm
500mm
500mm
500mm
10
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
8 DIMENSIONS
545
486 430
4-9×17Lumbar foramen
2-9
Unitmm 45
465 170 35 100
204.5
9 MOUNTING
1
2
3
4
10 mm 90° 70mm
10mm 5N·m
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
11
5
6
7
M5 3N·m
10 SECOND PROTECTIVE GROUNDING
1
3
E
L=E+(2~3)mm L
2
4
5
M5 3N·m
12
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
11 AC CONNECTION
1
2
4mm²~6mm²
30
10
U
V
W
N
PE
33
10
12.5~17.5mm
3 2 1
3
4 1
5
L3
N
L2
2
PE
L1
1
2mm 1.2±0.1N·m
2 6
click
1 2
7
8
9
10
click
OK
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
13
12 BACKUP LOAD CONNECTION
1
2
30
33 12.5~17.5mm
4mm²~6mm² 10
U V W
N PE
10
3 2 1
3
4 1
5
L2 L1
L3 2
PE
N
1
2mm 1.2±0.1N·m
2 6
click
1 2
7
8
9
10
click
OK
14
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
13 PV CONNECTION
TYPE 1 – Phoenix Contact
1
2.5-6mm2
12mm
4
2
2
click
5-8mm
5
3 1
×
OK
1 2
1 2
TYPE 2 1
2.5-6mm2
8-10mm
2
5-8mm
4 1
2
3
6
1 2
3 7
3 5
OK
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
15
14 BATTERY CONNECTION
1
2
3
OK
16
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
15 COMMUNICATION SETUP
15.1 Communication connection
1
2
M4
RJ45-1 RJ45-3 RJ45-5 Terminal-1
Terminal-2 USB
Terminal-3 RJ45-2 RJ45-4 RJ45-6
Terminal-4
Object Description Terminal 1
RJ45-3 Monitor
COM2 RS485A
2 RS485B
PIN definition
3
4
5
GND X
X
6 X
RJ45-4 BMS
COM5 X
GND
X
CANAH CANAL X
7 RS485A RS485A
8 RS485B RS485B
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
17
Object Description Terminal Terminal-1 DO1/DO2 4pin
Terminal-2
6pin
Terminal-3 DI*4/DRM0 6pin
Terminal-4
CT
6pin
PIN Definition
1
2
3
4
5
6
Multifunction Relay 1
Multifunction Relay 2
B
A
B
A
Smart Meter
PT100 Temperture Sensor
UFR Device
RS485A
RS485B
Positive
Negative
Positive
Negative
Ripple Control Receiver Device
DRMS Device
DI_4
DI_3
DI_2
DI_1
REF GEN/0
COM LOAD/0 or GND
Current Transformer 1
Current Transformer 2 Current Transformer 3
Red
Black
Red
Black
Red
Black
3
12
1 2 34
1 23456
8 7 6 5 4 3 2 1 PIN 12345678
2
12
1 2 34
1 2 34 56
4-8mm
1
4
5
M4
1.6N·m
18
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
6
7
1
2 15.2 Current Transformer connection
BATTERY ON
OFF
PV1
PV2
PV3
COM0
RJ45-1 RJ45-3 RJ45-5 Terminal-1
Terminal-2 USB
Terminal-3 RJ45-2 RJ45-4 RJ45-6
Terminal-4
GRID LOAD
123456
Red Black
CT Arrow pointing
to inverter
Grid
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
OK
U V W N PE
19
15.3 Ai-Dongle connection
1
2
1
1 2
2
4
3
3
4
5
6
7
8
OK
×
20
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
16 CONTACT
Please contact our Service Department if you have any technical questions about our products. The following information is needed to provide necessary assistance: —-Inverter model —-Inverter serial number —-Photovoltaic module model —-Photovoltaic modules number and strings number connected to each MPPT —-Fault code —-Installation location
EMEA Service email: [email protected] APAC Service email: [email protected] LATAM Service email: [email protected] Aiswei Greater China Service email: [email protected] Hotline: +86 400 801 9996 Taiwan Service email: [email protected] Hotline: +886 809089212 https://solplanet.net/contact-us
Scan QR code:
Scan QR code:
Android
iOS
QG0049_ASW05-12KH-T2-T3_EN_540-300254-00_0323
21
AISWEI Technology CO., Ltd