Mobatime Pl0 Profiline Quad Analogue Outdoor Clock User Guide

PL0 Profiline Quad Analogue Outdoor Clock

Product Information

The Profiline Quad is our premium analogue outdoor clock. It
features an elegant, modular housing concept featuring a
weather-resistant aluminum profile, a high-quality finish, and an
easy-to-install, maintenance-friendly design.

Key Features:

  • Modular housing concept
  • Weather-resistant aluminum profile
  • High-quality finish
  • Easy-to-install
  • Maintenance-friendly design

Product Usage Instructions

Step 1: Illumination

Decide if you want your clock to be illuminated or not:

OptionCode
None (no illumination)PL0
LED IlluminationPL2

Step 2: Clock Size

Choose the dial diameter that suits your needs:

Reading DistanceDial Diameter
45-50m55-60m
65-70m85-90m

Step 3: Clock Shape

Select the desired shape of your clock:

ShapeCode
Single-sidedQ1
Double-sidedQ2
Four-sidedQ4

Step 4: Time Code Variant

Choose the time code variant that suits your requirements:

Power SupplyHands MovementMax. Power ConsumptionAccuracy (Synchronized)Loss of Signal
MOBALINE SELF-SETTINGMXX< 20mA @ >17VAC (0.34W)17VAC (0.51W)
h/m SAM 100t
h#mmm_s SEM 100t

Note: For additional assistance and to ensure your Profiline
Quad meets all your requirements, feel free to consult our
experts.

ANALOGUE OUTDOOR CLOCK
PROFILINE QUAD
The Profiline is our premium analogue outdoor clock. It features an elegant, modular housing concept featuring a weather-resistant aluminum profile, a high-quality finish and an easy-to-install, maintenance-friendly design.

Profiline Quad analogue clock Mobatime

7 STEPS TO YOUR PROFILINE QUAD

To make sure your Profiline Quad meets all your requirements, you can assemble the components individually. Naturally, our experts will be happy to help.

1.

Are you looking for an illuminated clock?
ILLUMINATION
The Profiline Quad is available with or without illumination:

CODE PL0 PL2

ILLUMINATION none LED

2. How big does your clock need to be? SIZE

The Profiline Quad is available in four dial diameters. The reading distance varies depending on the dial, lighting, viewing angle, etc. These are the options:

Ø 40 cm 50 cm 60 cm 80 cm

READING DISTANCE 45-50m 55-60m 65-70m 85-90m

3.

What shape would you like?
SHAPE
The Profiline Quad is available in single-sided, double-sided and four-sided versions:

CODE Q1 Q2 Q4

SHAPE square, single-sided square, double-sided square, four-sided (Ø 60/80 only)

02

4. The Profiline Quad analog clock offers a variety of time code variants. Pick yours: TIME CODE

Code Time code Ø

Power supply

MOBALINE SELF-SETTING: MXX

Hands Movement

Max. power consumption

Accuracy (synchronized)

Loss of signal

M16 MOBALine 50­80 MOBALine M18 MOBALine 50­80 MOBALine

h/m SAM 100t h#mmm_s SEM 100t

< 20mA @ >17VAC (0.34W) <+/- 100ms < 30mA @ >17VAC (0.51W) <+/- 100ms

MOBALine: 12:00 position after 24 hours DCF active: 12:00 position after 7 days

NTP (LAN) SELF-SETTING (WITH UNICAST AND MULTICAST): NXX

N11 NTP N13 NTP

50­80 PoE 50­80 PoE

h/m NBU 190t PoE h#mmm_s NBU 190t S PoE

PoEclass 2: <1.6W3 / <3.2W4 <+/- 50ms

12:00 position after 24 hours

N01 NTP N03 NTP

50­80 230V (24VDC) 50­80 230V (24VDC)

h/m NBU 190t 24 + PS24 h#mmm_s NBU 190t S 24 + PS24

< 60mA @ 24VDC (<1.44W) <+/- 50ms

12:00 position after 24 hours

POLARIZED IMPULSES: IXX

I02 Min. impulse 50­80 12­60V impulse h/m NU 90t

-6mA @ 24VDC (0.14W)

Standstill

I06 Min. impulse 50­80 12­60V impulse h#mmm_s NU 90t SYN

6mA @ 24VDC (0.14W) 10mA @ 230VAC (<2W)

Standstill

I21

Min. impulse 50­80

12­60V impulse 45­265VAC

h#mmm_s

IBU 190t S

30mA @ 230VAC (<6.9W) –

Standstill

SERIAL: SXX

S01 Serial S03 Serial

50­80 230V 50­80 230V

h/m SU 190t 230 h#mmm_s SU 190t S 230

50mA @ 24VDC (<1.2W) 12mA @ 230VAC (<3W)

<+/- 100ms

12:00 position after 24 hours

IRIG/AFNOR: TXX

T51 IRIG/AFNOR 50­80 230V T53 IRIG/AFNOR 50­80 230V

h/m ATBU 190t 230 h#mmm_s ITBU 190t S 230

10mA @ 230VAC (<2.3W) <+/- 100ms

12:00 position after 24 hours

GPS / DCF 77 / MSF / WTD WIRELESS TIME DISTRIBUTION: RXX

R01 DCF / MSF2 50­80 230V R04 DCF / MSF2 50­80 230V

h/m BU 190t 230 h#mmm_s BU 190t S 230

230VAC (<3W)

<+/- 100ms

12:00 position after 7 days

R26 DCF 771

50­80 Lithium battery h/m FU 192t

<+/- 100ms

12:00 position after 7 days

R29 DCF 771,5

50­80 Lithium battery h/m FU 192t + BU 192t + CC –

<+/- 100ms

12:00 position after 7 days

R30 DCF 771

50­80 Lithium battery h/m BU 192t + AD 192.5

<+/- 100ms

12:00 position after 7 days

R31 DCF 771,5

50­80 Lithium battery h/m 2x BU 192t + AD 192.5 + CC –

<+/- 100ms

12:00 position after 7 days

R51 GPS6

50­80 Lithium battery h/m GU 192t V2

<+/- 200ms 12:00 position after 53 days

R54 GPS5 6

50­80 Lithium battery h/m GU 192t V2 + BU 192t + CC –

<+/- 200ms 12:00 position after 53 days

R80 WTD1

40­80 Lithium battery h/m BU 192t + RU

<+/- 100ms

12:00 position after 7 days

R88 WTD1 R90 WTD1

50­80 230V (24VDC) 50­80 230V (24VDC)

h/m SAM 100t + RM + PS24 230VAC (<18W)
h#mmm_s SEM 100t + RM + PS24

<+/- 200ms 12:00 position after 24 hours

QUARTZ: QXX

Q02 Quartz

50­80 Lithium battery h/m QU 192t

<+/- 4min/y7 –

Q03 Quartz5

50­80 Lithium battery h/m QU 192t + BU192t + CC –

<+/- 4min/y7 –

CLOCK CONTROLLER (WITH ILLUMINATION CONTROL): CXX

C01 MOBALine C03 MOBALine C09 NTP C11 NTP

50­80 50­80 50­80 50­80

230 VAC 230 VAC 230 VAC/PoE 230 VAC/PoE

h/m h#mmm_s h/m h#mmm_s

SAM 100t + DCC SEM 100t + DCC SAM 100t + NCC SEM 100t + NCC

0.55A @ >230VAC (<20W)
0.55A @ >230VAC (<20W) PoE, class 4, <22W

<+/- 100ms <+/- 100ms <+/- 100ms <+/- 100ms

MOBALine: 12:00 position after 24 hours DCF active: 12:00 position after 7 days

1 internal antenna and receiver (only for clocks without illumination) 2 without antenna, external antenna required 3 single-sided clock 4 cascaded double-sided clock 5 for double-sided clocks, cascading cable included 6 mini magnetic antenna and receiver 7 without synchronization

For special clockwork/time code variants, see document TE-800800 at www.mobatime.com in the Customers section

5. Choose your dial: DIAL

dial 120

dial 300

dial 315

03

Mobatime Profiline Quad analogue clock

6. Which type of glass is the right one? GLASS TYPE
Depending on the intended use, two glass options are available:

7.

Mineral glass (code 1) Ball-throw resistant (code 2)
Choose your installation:
I N S TA L L AT I O N

00 Wall mounting (E) For single-sided clocks.

01 / 21 / 50 01: Wall mounting (W) 21: Ceiling mounting (D) 50: Socket mounting (S) For double-sided clocks.
10 Wall bracket (WA) For double-sided clocks.

20 Ceiling suspension (DA) For double- and four-sided clocks.

YOUR PROFILINE QUAD IS COMPLETE

You can now order your Profiline Quad and calculate the corresponding code. Enter the abbreviation for each component of your choice in the bright field and find your Profiline Quad code. It serves as the order code or as the foundation for further steps.

1. Illumination Code

.

2. Size

Ø cm

.

3. Shape

Code

.

4. Time code

Code

.

5. Dial

Code

.

6. Glass type Code

.

7. Installation Code

.

Sequence number Code 0000

Example order code

30 Lateral pole mounting (SM) For double-sided clocks. Ø 50/60
40 Central pole mounting (ZM) For double- and four-sided* clocks.
Ø 50/60/80

*For four-sided clocks, a mast must be available on site (Ø 90150mm).

General properties

The following properties apply to all Profiline Quad clocks:

Housing

Aluminium, anodized

Profiline no illumination
Ø 60cm square, single-sided movement SAM 100t
dial 300 mineral glass wall suspension sequence number1

1. 2. 3. 4. 5. 6. 7.
PL0 . 60 . Q1 . M16 . 300 . 1 . 00 . 0000
1 The sequence number denotes special versions (e.g. clocks with a special dial). When ordering, please indicate the sequence number with 0000 (standard version); we will adapt this for any special version. Special versions can be reordered at any time stating the sequence number.
04

STANDARDS

Depending on the movement used in your Profiline Quad clock, the following standards apply:

MOVEMENT(S)
SAM 100t SEM 100t
NBU 190t PoE NBU 190t S PoE NBU 190t 24 NBU 190t S 24
NU 90t NU 90t SYN
IBU 190t S
SU 190t 230 SU 190t S 230
ATBU 190t 230 ITBU 190t S 230
BU 192t FU 192t QU 192t
BU 190t 230 BU 190t S 230
GU 192t V2

STANDARDS 2011/65/EU / 2014/30/EU / 2014/35/EU / 2016/797/EU / EN 50121-4 / EN 60950-1 / EN 61000-6-2 / EN 61000-6-3
2011/65/EU / 2014/30/EU / 2014/35/EU / 2016/797/EU / EN 50121-4 / EN 60950-1 / EN 61000-6-2 / EN 61000-6-4
2011/65/EU / 2014/30/EU / EN 61000-6-2 / EN 61000-6-3
2011/65/EU / 2014/30/EU / 2014/35/EU / 2016/797/EU / EN 50121-4 / EN 60950-1 / EN 61000-6-3 2011/65/EU / 2014/30/EU / 2014/35/EU / 2016/797/EU / EN 50121-4 / EN 60950-1 / EN 61000-6-1 / EN 61000-6-3 2011/65/EU / 2014/30/EU / 2014/35/EU / 2016/797/EU / EN 50121-4 / EN 60950-1 / EN 61000-6-2 / EN 61000-6-3 / IPPS
2011/65/EU / 2014/30/EU / EN 61000-6-2 / EN 61000-6-3
2011/65/EU / 2014/30/EU / 2014/35/EU / 2016/797/EU / EN 50121-4 / EN 60950-1 / EN 61000-6-1 / EN 61000-6-3 2011/65/EU / 2014/30/EU / 2016/797/EU / EN 50121-4 / EN 61000-6-2 / EN 61000-6-3

All Profiline Quad clocks are compliant with CE, RoHS and REACH.

05

TECHNICAL DATA

TECHNICAL DATA Operating conditions Degree of protection

PROFILINE QUAD -30 to +70 °C (0 to 95% relative humidity, non-condensing)
IP 54

E

W/D/S

WA/DA

SM

ZM

Ø

A

B

C

D

Weight

E

Weight

F

G

Weight Weight Weight

40 446

400

155

175

10

364

19

150

400

22

50 546

500

205

225

15

464

24

180

500

27

20

26

60 646

600

255

275

22

564

33

240

600

38

28

34

80 846

800

355

375

34

764

55

320

800

60

55

All dimensions in mm and weights in kg.

E (00)
B A
110
F WA (10)

D

D

ø10

35

50

C

C

cable input DA (20)

D (21) W (01)
S (50) 120

70

E

cable input
50 220
Ø 13 225

60

50 A

ø13 A

A G

260 220

ZM (40)

A

74

cable input 150

SM (30) 70

Ø 85

cable input

300

cable input

Ø 70

Ø 80-120

Do you have any questions? We are happy to help.
Product specifications are subject to change without notice.

Moser-Baer AG | Spitalstrasse 7 | CH-3454 Sumiswald Tel. +41 34 432 46 46 | Fax +41 34 432 46 99 [email protected] | www.mobatime.com

LE-800079.26 / 2023

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals