National Instruments Pxie-5110, 5111, 5113 Oscilloscope Datasheet

PXIe-5110, 5111, 5113 Oscilloscope

Product Information:

The PXIe-5110/5111/5113 is an 8-bit oscilloscope with respective
bandwidth and maximum sample rates of 100 MHz, 1 GS/s; 350 MHz, 3
GS/s; and 500 MHz, 3 GS/s. It is a PXIe instrument that requires
installation, configuration, and testing. The kit includes the
PXIe-5110/5111/5113 module, safety, environmental, and regulatory
information, and the Getting Started Guide.

Additional items may be required to operate the
PXIe-5110/5111/5113, depending on your application. These items are
not included in the kit and need to be obtained separately.

Documentation for the PXIe-5110/5111/5113 is available from the
Start menu by navigating to NI-SCOPE Documentation in the National
Instruments folder.

Product Usage Instructions:

  1. Before you begin, install and configure your chassis and
    controller.
  2. To prevent electrostatic discharge (ESD) from damaging the
    module, ground yourself using a grounding strap or by holding a
    grounded object, such as your computer chassis. Touch the
    antistatic package to a metal part of the computer chassis. Remove
    the module from the package and inspect it for loose components or
    other signs of damage. Do not install a module if it appears
    damaged in any way.
  3. Unpack any other items and documentation from the kit. Store
    the module in the antistatic package when the module is not in
    use.
  4. Refer to the product readme, available on the driver software
    media or online at ni.com/manuals, to ensure that your system meets
    the system requirements for using the NI-SCOPE instrument
    driver.
  5. If additional probe options are required, refer to Table 1 for
    the recommended probe based on module bandwidth. The NI part
    numbers for the recommended probes are PXIe-5110: SP200B,
    PXIe-5111: SP500X, and PXIe-5113: 780284-01.
  6. For more information about additional items required for
    operation, visit ni.com.

PXIe-5110

GETTING STARTED GUIDE
PXIe-5110/5111/5113
PXIe; 100 MHz, 350 MHz, or 500 MHz; 1 GS/s or 3 GS/s; 8-bit PXI Oscilloscope
Note Before you begin, install and configure your chassis and controller.
This document explains how to install, configure, and test the PXIe-5110/5111/5113. The PXIe-5110, PXIe-5111, and PXIe-5113 are 8-bit oscilloscopes with respective bandwidth and maximum sample rates of 100 MHz, 1 GS/s; 350 MHz, 3 GS/s; and 500 MHz, 3 GS/s.
Documentation for the PXIe-5110/5111/5113 is available from the Start menu by navigating to NI-SCOPE Documentation in the National Instruments folder.
Caution You can impair the protection provided by the PXIe-5110/5111/5113 if you use it in a manner not described in this document.
Contents
Verifying the System Requirements………………………………………………………………………………2 Unpacking the Kit……………………………………………………………………………………………………… 2 Other Equipment……………………………………………………………………………………………………….. 3 Preparing the Environment…………………………………………………………………………………………. 4 Installing the Software……………………………………………………………………………………………….. 4 Installing the PXIe-5110/5111/5113………………………………………………………………………………4 PXIe-5110/5111/5113 Front Panel……………………………………………………………………………….. 6 Configuring the PXIe-5110/5111/5113 in MAX……………………………………………………………..7 PXIe-5110/5111/5113 Self-Calibration………………………………………………………………………….8
Self-Calibrating the PXIe-5110/5111/5113……………………………………………………………..8 First Measurements……………………………………………………………………………………………………. 9
Making a Measurement with InstrumentStudio……………………………………………………….9 Making a Measurement with LabVIEW………………………………………………………………… 9 Compensating Passive Probes……………………………………………………………………………….9 Programming the PXIe-5110/5111/5113………………………………………………………………………11 Troubleshooting………………………………………………………………………………………………………. 13 What Should I Do if the PXIe-5110/5111/5113 Doesn’t Appear in MAX?……………….. 13 What Should I Do if the PXIe-5110/5111/5113 Fails the Self-Test?………………………… 13 Where To Go Next…………………………………………………………………………………………………… 14 Worldwide Support and Services……………………………………………………………………………….. 14

Verifying the System Requirements
To use the NI-SCOPE instrument driver, your system must meet certain requirements. Refer to the product readme, which is available on the driver software media or online at ni.com/manuals, for more information about minimum system requirements, recommended system, and supported application development environments (ADEs).
Unpacking the Kit
Refer to the following figure to identify the contents of the PXIe-5110/5111/5113 kit. Figure 1. PXIe-5110/5111/5113 Kit Contents

100 MPHXzIeO-s5c1il1lo0scope

xt Trig & PFI PFI 0
PFI 2

PFI 1

+5

PFI V M

3

5 V

1

2

3

4

1. PXIe-5110, PXIe-5111, or PXIe-5113
2. PXIe-5110, PXIe-5111, or PXIe-5113 Safety, Environmental, and Regulatory Information

3. PXIe-5110/5111/5113 Getting Started Guide (this document)
4. Maintain Forced-Air Cooling Note to Users

Notice To prevent electrostatic discharge (ESD) from damaging the module, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis. 1. Touch the antistatic package to a metal part of the computer chassis. 2. Remove the module from the package and inspect it for loose components or other signs of damage.
Notice Never touch the exposed pins of connectors.

2 | ni.com | PXIe-5110/5111/5113 Getting Started Guide

Note Do not install a module if it appears damaged in any way.
3. Unpack any other items and documentation from the kit. Store the module in the antistatic package when the module is not in use.

Other Equipment
There are several required items not included in your PXIe-5110/5111/5113 kit that you need to operate the PXIe-5110/5111/5113. Your application may require additional items not included in your kit to install or operate your PXIe-5110/5111/5113.
Required Items · A PXI Express chassis and chassis documentation · A PXI Controller or PC with a Device for PXI Remote Control system that meets the
system requirements specified in this guide and chassis documentation
Optional Items · PXI Slot Blocker Kit, 5 slot blockers (NI part number 199198-01) · PXI Filler Panel Kit, 17 filler panels (NI part number 778646-01) · HD-BNC (m)-to-BNC (m) cable, 1 m, 50 impedance (NI part number 784996-01) · Probes: refer to the following table for single-ended passive probes recommended for the
PXIe-5110/5111/5113.

Table 1. Probe Options for the PXIe-5110/5111/5113

Module Recommended Probe1 NI Part Number

Description

PXIe-5110 SP200B
PXIe-5111 SP500X PXIe-5113

780284-01 783629-01

200 MHz, ±60 V, 1x or 10x attenuation
500 MHz, ±300 V, 10x attenuation

Visit ni.com for more information about these additional items.

1 The recommended probe is based on module bandwidth. You can use either probe with any PXIe-5110/5111/5113 module.
PXIe-5110/5111/5113 Getting Started Guide | © National Instruments | 3

Preparing the Environment

Ensure that the environment in which you are using the PXIe-5110/5111/5113 meets the following specifications.

Temperature Operating Storage
Humidity Operating Storage
Pollution Degree Maximum altitude

0 °C to 55 °C -40 °C to 71 °C
10 % to 90%, noncondensing 5 % to 95%, noncondensing 2 4,600 m (at 25 °C ambient temperature)

Indoor use only.

Installing the Software
You must be an Administrator to install NI software on your computer. 1. Install an ADE, such as LabVIEW or LabWindowsTM/CVITM. 2. Visit ni.com/downloads/drivers and search for NI-SCOPE.
3. Download the latest version of NI-SCOPE by clicking Download and then running the executable (.exe) file.
Driver support for the PXIe-5110/5111/5113 was first available in NI-SCOPE 18.6. 4. Follow the instructions in the installation prompts.
Note Windows users may see access and security messages during installation. Accept the prompts to complete the installation. 5. When the installer completes, select Restart in the dialog box that prompts you to restart, shut down, or restart later.

Installing the PXIe-5110/5111/5113
Notice To prevent damage to the PXIe-5110/5111/5113 caused by ESD or contamination, handle the module using the edges or the metal bracket. 1. Ensure the AC power source is connected to the chassis before installing the module.
The AC power cord grounds the chassis and protects it from electrical damage while you install the module. 2. Power off the chassis.

4 | ni.com | PXIe-5110/5111/5113 Getting Started Guide

3. Inspect the slot pins on the chassis backplane for any bends or damage prior to installation. Do not install a module if the backplane is damaged.
4. Remove the black plastic covers from all the captive screws on the module front panel. 5. Identify a supported slot in the chassis. The following figure shows the symbols that
indicate the slot types.
Figure 2. Chassis Compatibility Symbols

NI PXIe-1062Q

1

2

3

4

5

1. PXI Express System Controller Slot 2. PXI Peripheral Slot 3. PXI Express Hybrid Peripheral Slot

4. PXI Express System Timing Slot 5. PXI Express Peripheral Slot

PXIe-5110/5111/5113 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots.
6. Touch any metal part of the chassis to discharge static electricity.
7. Ensure that the ejector handle is in the downward (unlatched) position.
8. Place the module edges into the module guides at the top and bottom of the chassis. Slide the module into the slot until it is fully inserted.

Figure 3. Module Installation

1

NI PXIe-1075
2 3
1. Chassis 2. Hardware Module 3. Ejector Handle in Downward (Unlatched) Position
9. Latch the module in place by pulling up on the ejector handle.
PXIe-5110/5111/5113 Getting Started Guide | © National Instruments | 5

10. Secure the module front panel to the chassis using the front-panel mounting screws.
Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis, which can improve the signal quality and electromagnetic performance. 11. Cover all empty slots using EMC filler panels or fill using slot blockers to maximize cooling air flow, depending on your application. 12. Power on the chassis.
PXIe-5110/5111/5113 Front Panel

PXIe-5110 100 MHz Oscilloscope

1
CH 0
MAX INPUT: 250 V
CAT I TO
50 : 7 V peak MAX 1 M : 250 V peak MAX

2

CH 1

ExtTrig & PFI

3

PFI 0

PFI 2

5

4

PFI 1

PFI 3

6

+5V MAX

5V

7

8

Signal 1 CH 0 2 CH 1

Table 2. Signal Descriptions

Connector Type

Description

BNC female

Analog input connection; digitizes data and triggers acquisitions.

6 | ni.com | PXIe-5110/5111/5113 Getting Started Guide

Signal
3 PFI 0 4 PFI 1 5 PFI 2 6 PFI 3 7 5 V square
wave 8 Ground

Table 2. Signal Descriptions (Continued)

Connector Type

Description

HD-BNC female

PFI line for digital trigger input/output.

Probe compensation terminal
Probe compensation terminal

Generates a 5 V square wave for passive probe compensation.
Ground reference for passive probe compensation.

Configuring the PXIe-5110/5111/5113 in MAX
Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX informs other programs about which NI hardware products are in the system and how they are configured. MAX is automatically installed with NI-SCOPE. 1. Launch MAX. 2. In the configuration tree, expand Devices and Interfaces to see the list of installed NI
hardware.
Installed modules appear under the name of their associated chassis. 3. Expand your Chassis tree item.
MAX lists all modules installed in the chassis. Your default names may vary.
Note If you do not see your module listed, press <F5> to refresh the list of installed modules. If the module is still not listed, power off the system, ensure the module is correctly installed, and restart. 4. Record the identifier MAX assigns to the hardware. Use this identifier when programming the PXIe-5110/5111/5113. 5. Self-test the hardware by selecting the item in the configuration tree and clicking SelfTest in the MAX toolbar.
The MAX self-test performs a basic verification of hardware resources.

PXIe-5110/5111/5113 Getting Started Guide | © National Instruments | 7

PXIe-5110/5111/5113 Self-Calibration
You can self-calibrate the PXIe-5110/5111/5113 to mitigate measurement error.
Self-calibrating the PXIe-5110/5111/5113 corrects for the following: · Gain errors · Offset errors · Interleaving spurs · Intermodule synchronization errors
Self-Calibrating the PXIe-5110/5111/5113
Running self-calibration enables the PXIe-5110/5111/5113 to yield full performance over its operating temperature range and two-year external calibration cycle.
Before running self-calibration, warm up the PXIe-5110/5111/5113 for 15 minutes.
Note Warm-up begins after the chassis and controller or PC is powered.

PXIe-5110/5111/5113 modules are externally calibrated at the factory, but for optimal performance, use self-calibration in any of the following situations: · When the module is placed in a new system · When any module in the chassis is installed, uninstalled, or moved · When the controller or PC wakes from sleep or hibernate, is reset, or is power cycled · To periodically adjust for small performance drifts that occur with product aging · When the system temperature changes more than ±5 °C from the temperature of the
previous self-calibration · Once 90 days have elapsed since the previous self-calibration

Tip You can use the nodes on the NI-SCOPE External Calibration palette to programmatically return the date and module temperature of the previous selfcalibration. You can also view this information by selecting the device in MAX.
Self-calibrate the PXIe-5110/5111/5113 programmatically in NI-SCOPE or on demand in MAX.

Option Description

NI-SCOPE Use the Self Calibrate node to self-calibrate the module.

MAX

Select the device in the Devices and Interfaces menu and click the SelfCalibrate button.

When the two-year external calibration interval expires, an external calibration is required to ensure performance within specifications over the subsequent two years.

8 | ni.com | PXIe-5110/5111/5113 Getting Started Guide

First Measurements

Making a Measurement with InstrumentStudio

1. Connect CH 0 to an input signal.

2. Launch InstrumentStudio at Start»National Instruments.

3. In the instrument header menu in the upper-right corner of the panel ( PXIe-5110/5111/5113 to the large panel with Add/Remove Devices.

), add the

4. Click Auto to automatically configure device settings for the detected signal.

5. If the soft front panel is not already running, click Run/Stop.

6. Add oscilloscope measurements to the channel by selecting Add/Remove in the measurement table of the oscilloscope.

For more information on the measurements available for oscilloscopes in InstrumentStudio, refer to the InstrumentStudio Manual at ni.com/manuals.

Making a Measurement with LabVIEW
1. Launch LabVIEW.
2. Select Help»Find Examples.
3. Open the example VI that you want to use by selecting Hardware Input and Output» Modular Instruments»NI-SCOPE (High-Speed Digitizers).

Tip If you are not sure which example to run, use the Quick Start VI, which is found under Hardware Input and Output»Modular Instruments»NISCOPE (High-Speed Digitizers)»Demos»niScope EX Quick Start.vi.
4. Follow any setup instructions in the VI and specify any desired settings.
5. Click Run to run the example program.

Compensating Passive Probes
Compensating passive probes increases the accuracy of your measurements by matching the capacitance of your probe to the capacitance of a particular oscilloscope input channel.

Note For more information on using InstrumentStudio, refer to the InstrumentStudio Manual at ni.com/manuals.

The PXIe-5110/5111/5113 can output a 1 kHz square wave that you can use to compensate passive probes.

To compensate a passive probe, complete the following steps: 1. Connect the BNC end of the probe to an input channel of your oscilloscope.
2. Connect the ground clip of the probe to the ground terminal on the front of the oscilloscope.

PXIe-5110/5111/5113 Getting Started Guide | © National Instruments | 9

3. Contact the tip of the probe to the 5 V square wave terminal on the front of the oscilloscope.
Note The probe compensation signal at this terminal is activated by default on the PXIe-5110/5111/5113. You can disable and re-enable the signal in InstrumentStudio with the Probe Compensation options in the instrument

header menu ( ) in the upper-right corner of the panel or programmatically in NI-SCOPE with Probe Compensation Signal Stop and Probe Compensation Signal Start.
4. In InstrumentStudio, configure the settings of the input channel to which you connected the probe. a) Set the channel to On to display the signal. b) Set the Input impedance of the channel to 1 M. c) Set the Vertical offset to 2.5 V. d) Match the Probe attenuation setting to the setting on your probe.
5. Adjust the vertical range on the input channel until the signal starts to clip and then increase the vertical range by one step so that it no longer clips.
This process ensures you are using the maximum dynamic range of the ADC.
6. Examine the digitized signal and adjust the tunable capacitor on the probe.
The probe is correctly compensated when the waveform appears as square as possible:

Compensated Correctly

Undercompensated

Overcompensated

Probe Adjustment Signal

Probe Adjustment Signal

Probe Adjustment Signal

Proper Amplitude of a 1 MHz Test Signal

Reduced Amplitude of a 1 MHz Test Signal

Increased Amplitude of a 1 MHz Test Signal

10 | ni.com | PXIe-5110/5111/5113 Getting Started Guide

Once compensated, the probe conveys signals to the input channel accurately, without artificially attenuating or amplifying frequency components of the signal.
Tip For the most accurate measurements: · Compensate probes for each channel of the oscilloscope; · Use a compensated probe only with the channel you used to compensate it; and · Compensate your probes frequently.
Programming the PXIe-5110/5111/5113
You can acquire data interactively using InstrumentStudio, or you can use the NI-SCOPE instrument driver to program your device in the supported ADE of your choice.
PXIe-5110/5111/5113 Getting Started Guide | © National Instruments | 11

Table 3. PXIe-5110/5111/5113 Programming Options

Application

Location

Description

InstrumentStudio

Available on 64-bit systems at any of the following locations:
· From the Windows start menu at Start»All Programs» National Instruments» NI-SCOPE»NI-SCOPE Soft Front Panel.
· From the Windows start menu at Start»All Programs» National Instruments» InstrumentStudio [year].
· From Measurement & Automation Explorer (MAX) by selecting a device and clicking Test Panels….

When you install NI-SCOPE on a 64-bit system, you can monitor, control, and record measurements from supported devices using InstrumentStudio. InstrumentStudio is a softwarebased front panel application that allows you to perform interactive measurements on several different device types, including oscilloscopes, in a single program.

NI-SCOPE Instrument Driver

LabVIEW–Available on the LabVIEW Functions palette at Measurement I/O»NI-SCOPE.
C or LabWindows/CVI–Available at Program Files»IVI Foundation»IVI»Drivers» niScope.

The NI-SCOPE API configures and operates the device hardware and provides customizable acquisition, control, analysis, and measurement options using LabVIEW VIs or LabWindows/CVI functions.

Microsoft Visual C/C++–Use examples located in the file directory UsersPublic DocumentsNational
InstrumentsNI­SCOPE examples.

You can modify an NI-SCOPE C example to create an application with Microsoft Visual C/C++. Copy an NI-SCOPE example to copy required project settings for include paths and library files. Alternatively, refer to the Creating an Application with Microsoft Visual C and C++ topic of the NI High-Speed Digitizers Help to manually add all required include and library files to your project.

12 | ni.com | PXIe-5110/5111/5113 Getting Started Guide

Troubleshooting

If an issue persists after you complete a troubleshooting procedure, contact NI technical support or visit ni.com/support.

What Should I Do if the PXIe-5110/5111/5113 Doesn’t Appear in MAX?
1. In the MAX configuration tree, expand Devices and Interfaces.
2. Expand the Chassis tree to see the list of installed hardware, and press <F5> to refresh the list.
3. If the module is still not listed, power off the system, ensure that all hardware is correctly installed, and restart the system.
4. Navigate to the Device Manager.

Operating System Description

Windows 10/8.1

Right-click the Start button, and select Device Manager.

Windows 7

Select Start»Control Panel»Device Manager.

5. Verify the PXIe-5110/5111/5113 appears in the Device Manager. a) Under an NI entry, confirm that a PXIe-5110/5111/5113 entry appears.

Note If you are using a PC with a device for PXI remote control system, under System Devices, also confirm that no error conditions appear for the PCI-to-PCI Bridge.
b) If error conditions appear, reinstall NI-SCOPE and the PXIe-5110/5111/5113.

What Should I Do if the PXIe-5110/5111/5113 Fails the Self-Test?
1. Restart the system. 2. Launch MAX, and perform the self-test again. 3. Power off the chassis. 4. Reinstall the failed module in a different slot. 5. Power on the chassis. 6. Perform the self-test again.

PXIe-5110/5111/5113 Getting Started Guide | © National Instruments | 13

Where To Go Next

Located online at ni.com/manuals
EXPLORE
the application development environment (ADE) for your application.

Located using the NI Example Finder

LEARN

CREATE

about hardware features or review device specifications.

custom applications with an application programming
interface (API).

Getting Started with LabVIEW
Getting Started with LabWindows/CVI

PXIe-5110 Specifications* PXIe-5111 Specifications* PXIe-5113 Specifications*
NI High-Speed Digitizers Help*

NI-SCOPE Soft Front Panel NI-SCOPE Instrument Driver
NI-SCOPE Examples*
NI High-Speed Digitizers Help*

Support ni.com/support

DISCOVER
more about your products through ni.com.

NI Oscilloscopes ni.com/oscilloscopes

Services ni.com/services

*This item is also installed with the driver software.

NI Community ni.com/community

Worldwide Support and Services
The NI website is your complete resource for technical support. At ni.com/support, you have access to everything from troubleshooting and application development self-help resources to email and phone assistance from NI Application Engineers.
Visit ni.com/services for information about the services NI offers.
Visit ni.com/register to register your NI product. Product registration facilitates technical support and ensures that you receive important information updates from NI.
NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information.

14 | ni.com | PXIe-5110/5111/5113 Getting Started Guide

Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.
© 2018 National Instruments. All rights reserved.