CFS126 BC Beam Clamp, Conduit Clip
Product Information:
- The product is a BC Beam Clamp and Conduit Clip.
- The BC Beam Clamp can hold a maximum flange thickness of 1/2
[13 mm]. - The Conduit Clip can hold 3/8 EMT, IMC & RIGID, 3/4 EMT,
IMC & RIGID, 1/2 EMT, IMC & RIGID, 1 EMT, IMC & RIGID,
1-1/4 RIGID, 1-1/4 EMT & IMC, 1-1/2 RIGID, 1-1/2 EMT & IMC,
2 RIGID and 2 EMT & IMC conduits. - The product should be used only as indicated in the instruction
sheets and training materials provided by nVent. - The product must never be used for a purpose other than the
purpose for which it was designed. - All instructions must be followed completely to ensure proper
and safe installation and performance. - Improper installation, misuse, misapplication or other failure
to follow nVent’s instructions and warnings may cause product
malfunction, property damage, serious bodily injury and/or death
and void the warranty. - Products that are manufactured using spring steel components
shall be used only in a non-corrosive indoor environment.
Product Usage Instructions:
BC Beam Clamp Installation:
- Install BC Beam Clamp onto a maximum flange thickness of 1/2
[13 mm]. - Tighten Beam Clamp Set Screw to 20 in.-lbs. [2.25 N-m].
Conduit Clip Installation:
- Select the appropriate Latching Hole from Sizing Chart.
- Fit Conduit into Conduit Clip.
- By Hand or with Channel Lock Pliers, snap Locking Tab into the
desired Latching Hole.
INSTRUCTION SHEET
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
BC Beam Clamp Installation 1. Install BC Beam Clamp onto a Maximum Flange Thickness of 1/2″ [13 mm]. 2. Tighten Beam Clamp Set Screw to 20 in.-lbs. [2.25 N-m]
Tighten
1
2
Insert
WARNING: 1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at
www.nVent.com and from your nVent customer service representative. 2. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings. 3. All instructions must be completely followed to ensure proper and safe installation and performance. 4. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property
damage, serious bodily injury and/or death, and void your warranty. 5. Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment. 6. All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any
other purpose. NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted. The customer is responsible for: a. Conformance to all governing codes. b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer. c. Using appropriate industry standard hardware as noted above. SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.
TECHNICAL SUPPORT: www.nVent.com
CFS126_M
1 OF 3
© 1998-2021 nVent All Rights Reserved
INSTRUCTION SHEET
Conduit Clip Installation 1. Select the appropriate Latching Hole from Sizing Chart
Global Part Local Part Number Number
Sizing Chart
Latch “A”
Latch “B”
2. Fit Conduit into Conduit Clip
6M
170790 3/8″ EMT, IMC & RIGID
N/A
For the 16M, compress the Bottom Gripping Tabs prior to
812M
installing the 3/4″ RIGID and 1″ RIGID Conduit
16M
3.
By Hand or with Channel Lock Pliers, snap Locking Tab into
20M 24M
the desired Latching Hole
32M
177130 170100 170110 170120 170130
3/4″ EMT, IMC & RIGID 1/2″ EMT, IMC & RIGID
1″ EMT, IMC & RIGID 3/4″ EMT, IMC & RIGID
1-1/4″ RIGID
1-1/4″ EMT & IMC
1-1/2″ RIGID
1-1/2″ EMT & IMC
2″ RIGID
2″ EMT & IMC
Bottom Gripping Tab
Latching Hole “A” (See Sizing Chart)
For Thread Impression Conduit Clip’s, select the appropriate Latching Hole from the Sizing Chart based on the Conduit Size being used.
Latching Hole “B” (See Sizing Chart)
BC Beam Clamp
Global Part Number
BC BCR EBC
Local Part Figure Flange Thickness Static Load Rating (lb [N])
Number No.
(in [mm])
F1
F2
F3
N/A 170380
1
1/2″ [13] Max
100 [445]
100 [445]
75 [334]
Ult. Static Load Rating (lb [N])
F4
F5
F6
F7
25 [111]
25 [111]
25 [111]
25 [111]
F5
F4 F1
F6
F2
F3
Indicated Loads are Static Load Limits or Ultimate Static Load Limits and should not be combined.
Global Part Number
BC BCR EBC
Local Part Number
N/A 170380
Hole Size
Thread “A”
Thread “B”
(in [mm]) Qty. Thread Size Qty. Thread Size
0.435 [11.05] 0.281 [7.14]
2
1/4-20 UNC 2B
1
10-24 UNC 2B
0.435 [11.05] 2 M6 X 1.00 – 6H 1 M6 X 1.00 – 6H
F7
Thread “B” Thread “A”
Thread “A”
Hole Size
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.
TECHNICAL SUPPORT: www.nVent.com
CFS126_M
2 OF 3
© 1998-2021 nVent All Rights Reserved
INSTRUCTION SHEET
BC Beam Clamp with Bottom Mount Conduit Clip
Global Part Local Part Figure
Number
Number No.
Description
Static Load Rating (lb [N])
BC6M BC812M BC16M BC20M
N/A
3/8″ [10]conduit to 1/2″ [13] maximum flange 1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange
3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange 1-1/4″ [32]conduit to 1/2″ [13] maximum flange
BC24M BC32M EBC6M EBC812M EBC16M EBC20M EBC24M
172580 160200 172590 172600 172610
1-1/2″ [38]conduit to 1/2″ [13] maximum flange
2″ [51]conduit to 1/2″ [13] maximum flange
2
3/8″ [10]conduit to 1/2″ [13] maximum flange
100 [445]
1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange
3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange
1-1/4″ [32]conduit to 1/2″ [13] maximum flange
1-1/2″ [38]conduit to 1/2″ [13] maximum flange
EBC32M
172620
2″ [51]conduit to 1/2″ [13] maximum flange
F
BC Beam Clamp with Side Mount Conduit Clip
Global Part Local Part Figure
Number
Number No.
Description
Static Load Rating (lb [N])
BC812MSM
1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange
BC16MSM
3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange
BC20MSM
N/A
1-1/4″ [32]conduit to 1/2″ [13] maximum flange
BC24MSM
1-1/2″ [38]conduit to 1/2″ [13] maximum flange
BC32MSM
2″ [51]conduit to 1/2″ [13] maximum flange
EBC6MSM
172650
3
3/8″ [10]conduit to 1/2″ [13] maximum flange
25 [111]
EBC812MSM 160180
1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange
EBC16MSM 172660
3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange
EBC20MSM 172670
1-1/4″ [32]conduit to 1/2″ [13] maximum flange
F
EBC24MSM 172680
1-1/2″ [38]conduit to 1/2″ [13] maximum flange
EBC32MSM 172690
2″ [51]conduit to 1/2″ [13] maximum flange
BC Beam Clamp with Side Mount Push Clip
Global Part Local Part Figure Number Number No.
Description
Ultimate Static Load Rating (lb [N])
BC8PSM
1/2″ [13] EMT conduit to 1/2″ [13] maximum flange
BC12PSM
N/A
3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange
BC16PSM EBC8PSM
172730
1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange
4
1/2″ [13] EMT conduit to 1/2″ [13] maximum flange
25 [111]
EBC12PSM 172740
3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange
F
EBC16PSM 172750
1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange
BC Beam Clamp with Bottom Mount Push Clip
Global Part Number
BC8P BC12P BC16P EBC8P EBC12P EBC16P
Local Part Figure Number No.
Description
Ultimate Static Load Rating (lb [N])
N/A
172700 172710 172720
1/2″ [13] EMT conduit to 1/2″ [13] maximum flange 3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange 1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange 5
1/2″ [13] EMT conduit to 1/2″ [13] maximum flange 3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange 1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange
25 [111]
F
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.
TECHNICAL SUPPORT: www.nVent.com
CFS126_M
3 OF 3
© 1998-2021 nVent All Rights Reserved