CFS126 BC Beam Clamp, Conduit Clip

Product Information:

  • The product is a BC Beam Clamp and Conduit Clip.
  • The BC Beam Clamp can hold a maximum flange thickness of 1/2
    [13 mm].
  • The Conduit Clip can hold 3/8 EMT, IMC & RIGID, 3/4 EMT,
    IMC & RIGID, 1/2 EMT, IMC & RIGID, 1 EMT, IMC & RIGID,
    1-1/4 RIGID, 1-1/4 EMT & IMC, 1-1/2 RIGID, 1-1/2 EMT & IMC,
    2 RIGID and 2 EMT & IMC conduits.
  • The product should be used only as indicated in the instruction
    sheets and training materials provided by nVent.
  • The product must never be used for a purpose other than the
    purpose for which it was designed.
  • All instructions must be followed completely to ensure proper
    and safe installation and performance.
  • Improper installation, misuse, misapplication or other failure
    to follow nVent’s instructions and warnings may cause product
    malfunction, property damage, serious bodily injury and/or death
    and void the warranty.
  • Products that are manufactured using spring steel components
    shall be used only in a non-corrosive indoor environment.

Product Usage Instructions:

BC Beam Clamp Installation:

  1. Install BC Beam Clamp onto a maximum flange thickness of 1/2
    [13 mm].
  2. Tighten Beam Clamp Set Screw to 20 in.-lbs. [2.25 N-m].

Conduit Clip Installation:

  1. Select the appropriate Latching Hole from Sizing Chart.
  2. Fit Conduit into Conduit Clip.
  3. By Hand or with Channel Lock Pliers, snap Locking Tab into the
    desired Latching Hole.

INSTRUCTION SHEET

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

BC Beam Clamp Installation 1. Install BC Beam Clamp onto a Maximum Flange Thickness of 1/2″ [13 mm]. 2. Tighten Beam Clamp Set Screw to 20 in.-lbs. [2.25 N-m]

Tighten

1

2

Insert

WARNING: 1. nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at
www.nVent.com and from your nVent customer service representative. 2. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings. 3. All instructions must be completely followed to ensure proper and safe installation and performance. 4. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property
damage, serious bodily injury and/or death, and void your warranty. 5. Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment. 6. All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any
other purpose. NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted. The customer is responsible for: a. Conformance to all governing codes. b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer. c. Using appropriate industry standard hardware as noted above. SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.

nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.

TECHNICAL SUPPORT: www.nVent.com

CFS126_M

1 OF 3

© 1998-2021 nVent All Rights Reserved

INSTRUCTION SHEET

Conduit Clip Installation 1. Select the appropriate Latching Hole from Sizing Chart

Global Part Local Part Number Number

Sizing Chart

Latch “A”

Latch “B”

2. Fit Conduit into Conduit Clip

6M

170790 3/8″ EMT, IMC & RIGID

N/A

For the 16M, compress the Bottom Gripping Tabs prior to

812M

installing the 3/4″ RIGID and 1″ RIGID Conduit

16M

3.

By Hand or with Channel Lock Pliers, snap Locking Tab into

20M 24M

the desired Latching Hole

32M

177130 170100 170110 170120 170130

3/4″ EMT, IMC & RIGID 1/2″ EMT, IMC & RIGID

1″ EMT, IMC & RIGID 3/4″ EMT, IMC & RIGID

1-1/4″ RIGID

1-1/4″ EMT & IMC

1-1/2″ RIGID

1-1/2″ EMT & IMC

2″ RIGID

2″ EMT & IMC

Bottom Gripping Tab

Latching Hole “A” (See Sizing Chart)

For Thread Impression Conduit Clip’s, select the appropriate Latching Hole from the Sizing Chart based on the Conduit Size being used.

Latching Hole “B” (See Sizing Chart)

BC Beam Clamp

Global Part Number
BC BCR EBC

Local Part Figure Flange Thickness Static Load Rating (lb [N])

Number No.

(in [mm])

F1

F2

F3

N/A 170380

1

1/2″ [13] Max

100 [445]

100 [445]

75 [334]

Ult. Static Load Rating (lb [N])

F4

F5

F6

F7

25 [111]

25 [111]

25 [111]

25 [111]

F5

F4 F1

F6

F2

F3

Indicated Loads are Static Load Limits or Ultimate Static Load Limits and should not be combined.

Global Part Number
BC BCR EBC

Local Part Number
N/A 170380

Hole Size

Thread “A”

Thread “B”

(in [mm]) Qty. Thread Size Qty. Thread Size

0.435 [11.05] 0.281 [7.14]

2

1/4-20 UNC 2B

1

10-24 UNC 2B

0.435 [11.05] 2 M6 X 1.00 – 6H 1 M6 X 1.00 – 6H

F7
Thread “B” Thread “A”

Thread “A”

Hole Size

nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.

TECHNICAL SUPPORT: www.nVent.com

CFS126_M

2 OF 3

© 1998-2021 nVent All Rights Reserved

INSTRUCTION SHEET
BC Beam Clamp with Bottom Mount Conduit Clip

Global Part Local Part Figure

Number

Number No.

Description

Static Load Rating (lb [N])

BC6M BC812M BC16M BC20M

N/A

3/8″ [10]conduit to 1/2″ [13] maximum flange 1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange
3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange 1-1/4″ [32]conduit to 1/2″ [13] maximum flange

BC24M BC32M EBC6M EBC812M EBC16M EBC20M EBC24M

172580 160200 172590 172600 172610

1-1/2″ [38]conduit to 1/2″ [13] maximum flange

2″ [51]conduit to 1/2″ [13] maximum flange

2

3/8″ [10]conduit to 1/2″ [13] maximum flange

100 [445]

1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange

3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange

1-1/4″ [32]conduit to 1/2″ [13] maximum flange

1-1/2″ [38]conduit to 1/2″ [13] maximum flange

EBC32M

172620

2″ [51]conduit to 1/2″ [13] maximum flange

F

BC Beam Clamp with Side Mount Conduit Clip

Global Part Local Part Figure

Number

Number No.

Description

Static Load Rating (lb [N])

BC812MSM

1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange

BC16MSM

3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange

BC20MSM

N/A

1-1/4″ [32]conduit to 1/2″ [13] maximum flange

BC24MSM

1-1/2″ [38]conduit to 1/2″ [13] maximum flange

BC32MSM

2″ [51]conduit to 1/2″ [13] maximum flange

EBC6MSM

172650

3

3/8″ [10]conduit to 1/2″ [13] maximum flange

25 [111]

EBC812MSM 160180

1/2″ [13] – 3/4″ [19] conduit to 1/2″ [13] maximum flange

EBC16MSM 172660

3/4″ [19] – 1″ [25]conduit to 1/2″ [13] maximum flange

EBC20MSM 172670

1-1/4″ [32]conduit to 1/2″ [13] maximum flange

F

EBC24MSM 172680

1-1/2″ [38]conduit to 1/2″ [13] maximum flange

EBC32MSM 172690

2″ [51]conduit to 1/2″ [13] maximum flange

BC Beam Clamp with Side Mount Push Clip

Global Part Local Part Figure Number Number No.

Description

Ultimate Static Load Rating (lb [N])

BC8PSM

1/2″ [13] EMT conduit to 1/2″ [13] maximum flange

BC12PSM

N/A

3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange

BC16PSM EBC8PSM

172730

1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange

4

1/2″ [13] EMT conduit to 1/2″ [13] maximum flange

25 [111]

EBC12PSM 172740

3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange

F

EBC16PSM 172750

1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange

BC Beam Clamp with Bottom Mount Push Clip

Global Part Number
BC8P BC12P BC16P EBC8P EBC12P EBC16P

Local Part Figure Number No.

Description

Ultimate Static Load Rating (lb [N])

N/A
172700 172710 172720

1/2″ [13] EMT conduit to 1/2″ [13] maximum flange 3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange 1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange 5
1/2″ [13] EMT conduit to 1/2″ [13] maximum flange 3/4″ [19] EMT or 1/2″ [13] Rigid conduit to 1/2″ [13] max flange 1″ [25] EMT or 3/4″ [19] Rigid conduit to 1/2″ [13] max flange

25 [111]

F
nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice.

TECHNICAL SUPPORT: www.nVent.com

CFS126_M

3 OF 3

© 1998-2021 nVent All Rights Reserved

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals