IN120 (WIFI)

The IN120 (WIFI) is an exit device designed for secure access
control in commercial buildings. It operates on six AA alkaline
batteries and features a lock motor that cycles after
installation.

The device comes with an inside cover that needs to be assembled
by hooking the top edge on the inside mounting plate, taking care
not to pinch the gasket. The cover needs to be secured with a
security Allen wrench. The device also features an audible beep
that sounds after a slight delay once the batteries are
installed.

The device comes with an operational check feature that needs to
be performed before closing the door. The device has a default
fail-safe or fail-secure mechanism in case of a power loss.

Product Usage Instructions

Follow the below instructions to use the IN120 (WIFI) exit
device:

  1. Securely place the controller in place and ensure the polarity
    is aligned properly.
  2. Install six AA alkaline batteries in the compartment and wait
    for the audible beep and lock motor cycle.
  3. Assemble the inside cover by hooking the top edge on the inside
    mounting plate, taking care not to pinch the gasket. Carefully
    press the bottom of the cover towards the door without pinching any
    wires. Secure the cover with a security Allen wrench.
  4. Perform an operational check by ensuring that the inside exit
    bar retracts latch before closing the door. The device has a
    default fail-safe or fail-secure mechanism in case of a power
    loss.

B. IN120 (WIFI)
1. Once controller is securely in place, place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly.
2. After batteries are installed, there is a slight delay; then an audible “beep” will sound and the lock motor will cycle.

IN120 / IN220 Exit Device

Fig. 5B
6 Inside Cover Installation
1. Assemble cover by hooking top edge on inside mounting plate taking care not to pinch gasket (top edge goes between plate and gasket).
2. Carefully press bottom of cover toward door without pinching any wires. 3. Secure the cover with a security allen wrench.
*Note location of installed ferrite bead (IN220 PoE) and excess wires (Fig. 6A, D).
Fig. 6B

Fig. 6D

Fig. 6A

Security Allen Screw

Fig. 6C

Copyright © 2016, 2019, 2021, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

04/30/21

30

1-800-810-WIRE · www.sargentlock.com · A8185D

IN120 / IN220 Exit Device
11 Operational Check
IMPORTANT: Be sure to test functions prior to closing door. In all cases, perform the following checks: 1. Ensure that inside exit bar retracts latch.
· To test cylinder, the following checks apply: Insert key into cylinder and rotate: a. There should be no friction against lock case, wire harness, or any other obstructions. If friction or binding occurs, readjust cylinder and wiring harness to eliminate issues. b. The key should unlock the outside lever and the lever should rotate freely.
· For units without a keypad, add card using LCT software* and then test.
· For units with a keypad, add pin and card using LCT software* and then test.
2. LED signaling: · After using a valid credential a green flash followed by motor unlock indicates normal operation (lock unlocks) · After using a valid credential a green flash followed by 4 beeps and 4 fast purple flashes ­ indicates low power. Check the input voltage. · If the input voltage is low, disconnect lock from power source and check power source voltage. If power source voltage is correct, inspect lock wiring for a possible short.
If the lock loses power, it will flash rapid blue for approximately one minute. Lock will default to programmed fail safe or fail secure. After that, the lock will no longer be functional. When you have completed the tests, close the door, ensuring latchbolt fully extends into strike plate without binding.
*Twenty (20) seconds after lock initialization
(single beep with lock motor actuation).

Copyright © 2016, 2019, 2021, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

04/30/21

1-800-810-WIRE · www.sargentlock.com · A8185D

31

SARGENT Manufacturing 100 Sargent Drive New Haven, CT 06511 USA 800-810-WIRE (9473) · www.sargentlock.com
HID and iCLASS are registered trademarks of HID Global Corporation.
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2016, 2019, 2021, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

A8185D – 04/21

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals