Ovia Ov75301wwb Edge-lit Led Panel Instruction Manual

OV75301WWB Edge-Lit LED Panel

Product Information:

  • Product Code: OV75301WWB
  • Colour Temperature: 3000K (Warm White)
  • Input Voltage/Frequency: 230V~ 50Hz
  • Wattage: 30W
  • Outer Dimensions: 595mm x 595mm
  • Driver: OVCG7530B
  • Dimmable: No (OVCGMF0001 Multi-Functional
    Driver Available – Sold Separately)
  • Ambient Temperature (Ta): -20°C – +40°C
  • Fixture Class: Class II (Mains To Remote
    Driver), Class III (Remote Driver To Panel)
  • Supply Connection: Pre-wired Flow Connector
    & Cable 2G 0.75mm2 H03VVH2-F (200mm Long)
  • IP Rating: IP20
  • Flammability Rating: TP(a)

Product Usage Instructions:

  1. Make sure the input voltage is 230V~ and the frequency is
    50Hz.
  2. Place the panel in the desired location, ensuring it fits
    within the outer dimensions of 595mm x 595mm.
  3. If using the dimmable feature, purchase the OVCGMF0001
    Multi-Functional Driver separately and connect it to the OVCG7530B
    driver.
  4. The recommended ambient temperature range for operation is
    between -20°C and +40°C.
  5. Depending on the installation type, follow the appropriate
    fixture class requirements:
    • If connecting the panel directly to the mains, ensure a Class
      II fixture class.
    • If using a remote driver, make sure to use a Class III fixture
      class between the remote driver and the panel.
  6. Connect the panel to the power supply using the supplied
    pre-wired flow connector and cable. The cable length is 200mm and
    has a 2G 0.75mm2 H03VVH2-F specification.
  7. The IP rating of the panel is IP20, which means it is protected
    against solid objects larger than 12mm and does not provide water
    protection.
  8. The flammability rating of the panel is TP(a), indicating it
    has passed the necessary tests for fire resistance.

SPECIFICATIONS:

Input Voltage/Frequency Wattage
Outer Dimensions Driver Product Code Colour Temperature
Dimmable Temperature Ambient (Ta)
Fixture Class 230V~ Supply Connection
IP Rating Flammability Rating
UGR Frame RAL Colour
Body Material Warranty

OV75301WWB 3000K (Warm White)

OV75301CWB

OV75301DLB

OV751301WWB

OV751301CWB

230V~ 50Hz

30W

595mm x 595mm

OVCG7530B

4000K (Cool White) 6000K (Daylight) 3000K (Warm White) 4000K (Cool White)

No (OVCGMF0001 Multi-Functional Driver Available – Sold Separately)

-20oC – +40oC

Class II (Mains To Remote Driver), Class III (Remote Driver To Panel)

Pre-wired Flow Connector & Cable 2G 0.75mm2 H03VVH2-F (200mm Long)

IP20

TP(a)

<23

<19

RAL 9003 (Signal White)

Powder Coated Aluminium, Polypropylene (PP) Lens

5 Years

OV751301DLB 6000K (Daylight)

COMPLIANT WITH:
The products listed in these instructions have been tested and comply with the following:

· LV (2014/35) & EMC (2014/30) Statutory Instruments & Directives

· BS EN 60598-1

· BS EN 55015

· BS EN 60598-2-2

· BS EN 61000-3-2

· BS EN 61000-3-3 · BS EN 61547

MULTI-FUNCTIONAL DIMMABLE DRIVER (AVAILABLE – SOLD SEPARATELY)

All 230V~ Standard & Low-Glare TP(a) LED Backlit Panels are compatible with the OVIA OVCGMF0001 Multi-Functional Dimmable Driver for when dimming is required. The DIP Switches must be configured to the below setting / specification for best compatability results;

PIN typ. Irated Output

1

2

3

4

Voltage

29W 600mA 42VDC

ON

ON

ON

34W 700mA 42VDC ON

– –

ON

ON

36W 750mA 42VDC – –

– –

ON

ON

39W 800mA 42VDC – –

ON

– –

ON

41W 850mA 42VDC – –

– –

– –

ON

43W 900mA 42VDC ON

ON

ON

– –

46W 950mA 42VDC – –

– –

ON

– –

48W 1000mA 42VDC – –

ON

– –

– –

48W 1050mA 40VDC ON

– –

– –

– –

48W 110mA 38VDC – –

– –

– –

– –

Errors & Omissions excluded. Specification is subject to change without notice.

OVIA Limited, Scolmore House, Mariner, Lichfield Road Ind. Estate, Tamworth, Staffordshire, B79 7UL

Telephone: 01827 300640 E-mail: [email protected]

Website: www.oviaUK.com

V4.0

Installation, Technical & Safety Information Sheet
230V~ 30W 600 x 600mm Standard & Low-Glare IP20 Backlit
INCEPTOR SLATE BACKLIT TP(a) LED Panels
GENERAL INFORMATION
PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCE.
Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or use of this product, consult a competent electrician.
· Before commencing any electrical work, ensure the mains isolator on the consumer unit / fuse board is in the `OFF’ position, to prevent the possibility of electric shock.
· Before commencing installation, ensure the fitting is complete with the fixings required. · The fitting should be mounted on a smooth, flat surface, noting the position of any pipes or wiring behind the fixed surface to prevent the risk of
damage. · Installation should be carried out in accordance with the latest edition of the National Wiring Regulations. If in any doubt please consult a
qualified electrician. · The LED light source is not dimmable. · This LED light source is not replaceable.

RANGE OVERVIEW
230V~ Standard & Low-Glare TP(a) LED Backlit Panels With Remote Driver & Pre-wired Flow Connector – White Finish · OV75301WWB – 30W (600mm x 600mm) LED Panel – 3000K (Warm White) · OV75301CWB – 30W (600mm x 600mm) LED Panel – 4000K (Cool White) · OV75301DLB – 30W (600mm x 600mm) LED Panel – 6000K (Daylight) · OV751301WWB – 30W (600mm x 600mm) Low-Glare LED Panel – 3000K (Warm White) · OV751301CWB – 30W (600mm x 600mm) Low-Glare LED Panel – 4000K (Cool White) · OV751301DL – 30W (600mm x 600mm) Low-Glare LED Panel – 6000K (Daylight)
Accessories · OVREC731 – Recess Frame For 600mm X 600mm Panels · OVSUSP731 – Suspension Kit For 600mm x 600mm LED Panels · OVSURF734 – Surface Frame For Backlit 600mm x 600mm Panels
WIRING INSTRUCTIONS
The remote driver supplied with each panel is pre-wired to a 3 pole male Flow connector. The female connector (CT105F) is supplied with the driver and terminated as follows:
Remove the cover off the CT105F Flow connector.
Terminate the 2 core supply cable(s) in to the terminals, 2.5mm2 Max. (enables 2 connections per terminal): L (Live) – Brown N (Neutral – Blue
Ensuring all terminals are secure and cable(s) outer sheathing is clamped, replace the cover and lock ensuring secure.

INSTALLATION
Connect both male and female Flow connectors together and connect the inline DC connector from the driver to the panel. If mounting in to a suspended ceiling frame please follow the diagrams below, ensuring the panel is safely and securely positioned. If mounting in to one of the accessories (suspension kit), the instructions are provided with the accessory.

Fig.1

Fig.2

Fig.3

Fig.4

Fig.5

Fig.6

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals