Dr Prepare Dccfa1 26w Air Circulator Fan User Guide

DCCFA1 26W Air Circulator Fan

Product Information

The 26W Air Circulator Fan, model DCCFA1, is a compact and
lightweight fan designed to provide a cool breeze in any room. It
has a rated voltage of AC120V/60Hz and consumes 26W of power. The
product weighs 2.75 lbs/1.25 kg and measures 10*8*11.6
in/25.4*20*29.5 cm. The fan blade diameter is 5.9 in/15 cm. The
front guard and fan blades can be disassembled for easy
cleaning.

Product Usage Instructions

Before using the fan, read the user guide carefully. Ensure that
the supplied voltage is appropriate and refer to the voltage and
frequency ratings on the specification label before use. To use the
fan, follow these steps:

  1. Ensure that the control knob is in the 0 position before
    plugging in the fan.
  2. Plug in the power supply and rotate the knob to your desired
    power mode with or without auto-oscillation. The upper half control
    panel comes with left-to-right auto-oscillation, while the lower
    half control panel does not oscillate.
  3. To change the fan’s tilt angle, manually adjust it from -10deg
    to 90deg.

When not using the fan, turn off the power and unplug it. Do not
use the fan in hot and humid environments or store flammable or
explosive materials around it. If you notice any abnormalities like
abnormal sound, peculiar smell, high temperature, or irregular
rotation of the fan, stop using it immediately.

Cleaning and Maintenance

The front guard and fan blades can be disassembled for easy
cleaning. Follow these steps:

  1. Unscrew the two fixing screws on the rear guard with a
    screwdriver.
  2. Press the 4 rear guard buckles to remove the front guard.
  3. Pull out the fan blades for cleaning.
  4. Wipe the fan’s motor and rear guard with a neutral detergent
    and a moist soft cloth.
  5. The front guard and fan blades can be washed with water.
  6. Wait until the front guard and fan blades have dried, then
    assemble the whole fan in the reverse order of disassembly. Note:
    For assembly, align the fan blades’ slot and insert the pole to the
    bottom until it can’t move further.

Do not operate the fan with wet hands or forcefully pull the
power cord to unplug it.

26W AIR CIRCULATOR FAN
DCCFA1
This user guide offers a brief walkthrough of the circulator fan’s features. Please keep the guide in hand for future reference.
Still need help? Feel free to email us at [email protected]
User Guide

DON’TS WHEN USING THE FAN
Please read through this user guide before first use.
It is forbidden to rinse the fan body directly with water. Do not turn off the fan by unplugging the power plug directly. Do not insert your fingers or other objects into the fan’s front/rear guard, or running fan blades. Do not put hair, fabric, etc. near the fan to avoid being drawn in and causing danger. Do not spray cleaning liquid or pesticides on the fan to avoid damaging the casing surface. Not intended for persons (including children) who are physically or mentally disabled or lack relevant experience/skills, unless instructed by the person responsible for the product’s safety.
When it is not in use, turn off the power and unplug the fan.

SPECIFICATIONS

Item Model Rated Voltage Rated Power Net Weight Product Size Fan Blade Diameter

Air Circulator Fan DCCFA1 AC120V / 60Hz 26W 2.75 lbs / 1.25 kg 10*8*11.6 in / 25.4*20*29.5 cm 5.9 in / 15 cm

– 01 –

SAFETY PRECAUTIONS

NOTICE

Please read this manual carefully before using the fan. The Company reserves the right to interpret the instructions. The appearance of the actual product shall prevail. In the case of product technology or software upgrades, there will be no prior notice.

1. Transportation
When moving, be sure to shut off the fan and unplug the power plug.
2. Power Cord
Do not pinch, bend or twist the AC power cord excessively, otherwise the cord could be exposed or broken.
If the power cord is damaged, it must be replaced by professionals from the manufacturer, its maintenance department, or a similar department to avoid hidden risks.

3. Usage
Please refer to the voltage and frequency ratings on the specification label before use, and ensure the supplied voltage is appropriate.
In the case of abnormal sound, peculiar smell, high temperature, irregular rotation of the fan, or other abnormalities, please stop using the product immediately.

4. Warning (improper use may cause electric shock, fire, injury, and other damages) Do not use this product on unstable platforms where it may topple easily.

Do not use this product in hot and humid environments (like bathrooms), and harsh environments.
It is forbidden to store flammable or explosive materials around the fan body.

– 02 –

USE METHOD

1. Before plugging in, make sure the control knob is in the “0” position.

2. Plug in the power supply, and rotate the knob to your desired power mode, with or without auto-oscillation.

(The upper half control panel comes with left-to-right auto-oscillation, while for the lower half control panel, the fan does not oscillate.)
3. To change the fan’s tilt angle, you can manually adjust the fan from -10deg to 90deg.

0 3

0 1

2 3

2 3
0
1 2
Control panel

CLEANING AND MAINTENANCE
For easy cleaning, the front guard and fan blades can be disassembled.
WARNING

Do not operate with wet hands

Do not forcefully pull the power cord to unplug the fan.

Prohibited

Prohibited
Oil Ker
Alcohol

– 03 –

0 1

DISASSEMBLY & ASSEMBLY METHOD
1. Unscrew the two fixing screws on the rear guard with a screwdriver (not included). 2. Press the 4 rear guard buckles to remove the front guard.
3. Then pull out the fan blades for cleaning. 4. Wipe the fan’s motor and rear guard with a neutral detergent and a moist soft cloth.
5. The front guard and fan blades can be washed with water. 6. Wait until the front guard and fan blades have dried, then assemble the whole fan in the
reverse order of disassembly. Note: For assembly, please align the fan blades’ slot and insert the pole to the bottom until it can’t move further.
– 04 –

TROUBLESHOOTING
If the fan cannot work properly after the following rectifications, please contact the Dr. Prepare service team for help.

Fault Issues

Fault Reasons

Solution

The fan does not work

Dead electrical outlet

Change to a live socket

Poor power cord connections Connect the power cord firmly

Emits noise during operation

Dirty fan blades Loose fan blades Motor failure

Remove the front guard and clean the fan blades
Fix the fan blades
Contact our service team

Incorrect mode chosen The fan does not oscillate
Control knob failure

Please turn to the correct knob position
Contact our service team

Fan blades get stuck

The blades could be jammed Unplug the fan and take out

by some objects

the objects

WARRANTY COVERAGE
1. Dr. Prepare Air Circulator Fans are covered by a 1-year limited warranty from the original purchase date. The Company is not responsible for any injury caused by improper use.
2. In any of the following circumstances, no free preferential treatment will be given during the warranty period.
Failure or damage caused by natural or man-made errors. Failure or damage caused by unauthorized modification or maintenance of the product by personnel is not affiliated with the Company.